Evaluating the Educational Effectiveness of Surface Radioactive Contamination Survey Techniques
Open Access
- 1 October 2025
- journal article
- research article
- Published by EDP Sciences in Radioprotection
- Vol. 60 (4) , 370-372
Abstract
In this study, we evaluated the educational effectiveness of training by reviewing recorded data on contamination survey techniques and real-time display feedback. An optical flow (OF) sensor and a distance sensor were used to measure the speed and distance, respectively. The sensors were mounted on a radiation measuring device, and the contamination survey techniques of the 12 participants were recorded. The recorded data and real-time technique feedback was used to conduct training, after which the participants performed contamination surveys once more. Speed and distance both significantly decreased after training, with speed dropping from 4.70 to 3.45 cm s −1 and distance decreasing from 1.16 to 0.90 cm. Additionally, variations during surveys showed a significant reduction.Keywords
Funding Information
- Japan Society for the Promotion of Scienc (JP23K11914)
This publication has 3 references indexed in Scilit:
- Are Online Simulations for Radiation Emergency Medical Preparedness Less Effective in Teaching Than Face-to-Face Simulations?Disaster Medicine and Public Health Preparedness, 2023