Ryutaro Mori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryutaro Mori has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Koichi Okuda
Department of Radiation Science, Hirosaki University Graduate School of Health Sciences, Hirosaki-shi, Japan
2 shared publications - Shota Hosokawa
Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Aomori, Japan
2 shared publications - Yasuyuki Takahashi
Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Aomori, Japan
2 shared publications A. Nakamura
Department of Radiological Technology
1 shared publicationH. Ose
Department of Radiological Technology
1 shared publication- Kazuya Tsushima
Department of Radiology, Tsugaru General Hospital, 12-3 Iwaki-cho, Goshogawara 037-0074, Aomori, Japan
1 shared publication
Latest Publications
- Open Access
Evaluation of Scatter Correction Methods in SPECT Images: A Phantom-Based Study of TEW and ESSE Methods
We compared scatter correction (SC) in single-photon emission computed tomography (SPECT) images using effective scatter source estimation (ESSE) and the triple-energy window (TEW) method. We acquired 99mTc and 123I images of brain, myocardial, and performance phantoms containing rods with different diameters. We assessed contrast ratios (CRs) and ROI-based noise metrics (coefficient of variation, signal-to-noise ratio, and contrast-to-noise ratio [CNR] ). Under 99mTc, ESSE yielded higher CRs than TEW across all phantoms (mean difference 0.04, range 0.01–0.05) and produced the highest CNR in the myocardial phantom, improving the conspicuousness of the simulated defect. Under 123I, CR differences between ESSE and TEW were small and inconsistent (performance phantom: −0.04 to 0.06; brain phantom: −0.01 to 0.00). A Monte Carlo simulation (point source in air) showed substantial photopeak window penetration for cardiac high-resolution collimators (40.0%) but low penetration for medium-energy general-purpose collimators (5.1%), supporting photopeak contamination as a contributor to the 123I findings and potentially attenuating the apparent advantage of model-based SC that does not explicitly account for penetration photons. These findings suggest that SC selection should consider the radionuclide and imaging target and that ESSE might be a reasonable option for 99mTc myocardial imaging under the settings examined.
Open AccessEvaluation of Scatter Correction Methods in SPECT Images: A Phantom-Based Study of TEW and ESSE Methods
We compared scatter correction (SC) in single-photon emission computed tomography (SPECT) images using effective scatter source estimation (ESSE) and the triple-energy window (TEW) method. We acquired 99mTc and 123I images of brain, myocardial, and performance phantoms containing rods with different diameters. We assessed contrast ratios (CRs) and ROI-based noise metrics (coefficient of variation, signal-to-noise ratio, and contrast-to-noise ratio [CNR] ). Under 99mTc, ESSE yielded higher CRs than TEW across all phantoms (mean difference 0.04, range 0.01–0.05) and produced the highest CNR in the myocardial phantom, improving the conspicuousness of the simulated defect. Under 123I, CR differences between ESSE and TEW were small and inconsistent (performance phantom: −0.04 to 0.06; brain phantom: −0.01 to 0.00). A Monte Carlo simulation (point source in air) showed substantial photopeak window penetration for cardiac high-resolution collimators (40.0%) but low penetration for medium-energy general-purpose collimators (5.1%), supporting photopeak contamination as a contributor to the 123I findings and potentially attenuating the apparent advantage of model-based SC that does not explicitly account for penetration photons. These findings suggest that SC selection should consider the radionuclide and imaging target and that ESSE might be a reasonable option for 99mTc myocardial imaging under the settings examined.
- Open Access
- 1 October 2025
- Published by EDP Sciences in Radioprotection
- Vol. 60 (4) , 370-372
Evaluating the Educational Effectiveness of Surface Radioactive Contamination Survey Techniques
In this study, we evaluated the educational effectiveness of training by reviewing recorded data on contamination survey techniques and real-time display feedback. An optical flow (OF) sensor and a distance sensor were used to measure the speed and distance, respectively. The sensors were mounted on a radiation measuring device, and the contamination survey techniques of the 12 participants were recorded. The recorded data and real-time technique feedback was used to conduct training, after which the participants performed contamination surveys once more. Speed and distance both significantly decreased after training, with speed dropping from 4.70 to 3.45 cm s −1 and distance decreasing from 1.16 to 0.90 cm. Additionally, variations during surveys showed a significant reduction.
- 1 October 2025
- Published by EDP Sciences in Radioprotection
- Vol. 60 (4) , 370-372
Open AccessEvaluating the Educational Effectiveness of Surface Radioactive Contamination Survey Techniques
In this study, we evaluated the educational effectiveness of training by reviewing recorded data on contamination survey techniques and real-time display feedback. An optical flow (OF) sensor and a distance sensor were used to measure the speed and distance, respectively. The sensors were mounted on a radiation measuring device, and the contamination survey techniques of the 12 participants were recorded. The recorded data and real-time technique feedback was used to conduct training, after which the participants performed contamination surveys once more. Speed and distance both significantly decreased after training, with speed dropping from 4.70 to 3.45 cm s −1 and distance decreasing from 1.16 to 0.90 cm. Additionally, variations during surveys showed a significant reduction.