A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
- 25 April 2014
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (8) , 1705-1710
Abstract
The purpose of this study was to investigate whether cement-augmented screw osteosynthesis results in stability comparable to conventional fixed-angle locking plate osteosynthesis using cadaveric bones to model a Sanders type 2B fracture. Seven pairs of fresh frozen human calcanei and the corresponding tali were used. The specimens were assigned pairwise to two study groups in a randomised manner. In order to determine the initial quasi-static stiffness of the bone-implant construct, testing commenced with quasi-static compression ramp loading; subsequently, sinusoidal cyclic compression loading at 2 Hz was performed until construct failure occurred. Initial dynamic stiffness (cycle 1), range of motion (ROM), cycles to failure and load to failure were determined from the machine data during the cyclic test. In addition, at 250-cycle intervals, Böhler’s angle and the critical angle of Gissane were determined on mediolateral X-rays shot with a triggered C-arm; 5° angle flattening was arbitrarily defined as a failure criterion. Bone mineral density was normally distributed without significant differences between the groups. The augmented screw osteosynthesis resulted in higher stiffness values compared to the fixed-angle locking plate osteosynthesis. The fracture fragment motion in the locking plate group was significantly higher compared to the group with augmented screw osteosynthesis. The results of this study indicate that in our selected test set-up augmented screw osteosynthesis was significantly superior to the conventional fixed-angle locking plate osteosynthesis with respect to primary stability and ROM during cyclic testing.Keywords
This publication has 26 references indexed in Scilit:
- Displaced intra-articular calcaneal fractures.2005
- SRS Cancellous Bone Cement Augmentation of Calcaneal Fracture FixationFoot & Ankle International, 2005
- A Comparison of Plates With and Without Locking Screws in a Calcaneal Fracture ModelFoot & Ankle International, 2005
- Minimally-invasive treatment of calcaneal fracturesInjury, 2004
- Percutaneous, arthroscopically-assisted osteosynthesis of calcaneus fracturesArchives of orthopaedic and trauma surgery, 2002
- The Value of Subtalar Arthroscopy in the Management of Intra-articular Calcaneus FracturesFoot & Ankle International, 2002
- Open Reduction and Augmentation of Internal Fixation With an Injectable Skeletal Cement for the Treatment of Complex Calcaneal FracturesJournal of Orthopaedic Trauma, 2000
- The Vascularization of the Os Calcaneum and the Clinical ConsequencesClinical Orthopaedics and Related Research, 1999
- Superior Compressive Strength of a Calcaneal Fracture Construct Augmented with Remodelable Cancellous Bone Cement*Journal of Bone and Joint Surgery, 1999
- Wound-Healing Risk Factors After Open Reduction and Internal Fixation of Calcaneal FracturesFoot & Ankle International, 1998