Sascha Rausch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sascha Rausch has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Kajetan Klos
Senior Surgeon, Gelenkzentrum Rhein- Main, Hochheim, Germany
7 shared publicationsBoyko Gueorguiev
Professor and Leader, Biomedical Development Program, AO Research Institute Davos, Davos, Switzerland
4 shared publicationsFlorian Gras
Department of Traumatology, Hand and Reconstructive Surgery, Friedrich-Schiller-Universität Jena, Jena, Germany
3 shared publicationsGunther O. Hofmann
Trauma Department, Jena University Hospital, Jena, Germany ; Berufsgenossenschaftliche Kliniken Bergmannstrost Halle, Halle, Germany
3 shared publicationsPaul Simons
Senior Surgeon, Gelenkzentrum Rhein- Main, Hochheim, Germany
3 shared publicationsThomas Mückley
Department of Traumatology and Orthopaedic Surgery Helios Klinikum Erfurt, Berlin, Germany
3 shared publications
Latest Publications
- 1 November 2020
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 59 (6) , 1156-1161
Comparison of Ligament-Repair Techniques for the Syndesmosis: A Simulated Cadaveric Weight-Bearing Computed Tomography Analysis
- 1 November 2020
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 59 (6) , 1156-1161
Comparison of Ligament-Repair Techniques for the Syndesmosis: A Simulated Cadaveric Weight-Bearing Computed Tomography Analysis
- 1 July 2019
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 58 (4) , 734-738
Computed Tomography Analysis for Quantification of Displacement of the Distal Fibula in Different Foot Positions With Weightbearing and Sequentially Increased Instability: An Anatomic Cadaveric Study on Syndesmosis
- 1 July 2019
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 58 (4) , 734-738
Computed Tomography Analysis for Quantification of Displacement of the Distal Fibula in Different Foot Positions With Weightbearing and Sequentially Increased Instability: An Anatomic Cadaveric Study on Syndesmosis
- Open Access
- 20 June 2015
- Published by Medknow in Archives of Trauma Research
- Vol. 4 (2) , e24622
Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures
Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, while the penetration of the contralateral bone surface may result in tendon irritations and ruptures. The intraoperative control of fracture reduction and implant positioning is limited in the common postero-anterior and true lateral two-dimensional (2D)-fluoroscopic views. Therefore, additional 2D-fluoroscopic views in different projections and intraoperative three-dimensional (3D) fluoroscopy were recently reported. Nevertheless, their utility has issued controversies. The following questions should be answered in this study; 1) Are the additional tangential view and the intraoperative 3D fluoroscopy useful in the clinical routine to detect persistent fracture dislocations and screw misplacements, to prevent revision surgery? 2) Which is the most dangerous plate hole for screw misplacement? A total of 48 patients (36 females and 13 males) with 49 unstable distal radius fractures (22 x 23 A; 2 x 23 B, and 25 x 23 C) were treated with a 2.4 mm variable angle LCP Two-Column volar distal radius plate (Synthes GmbH, Oberdorf, Switzerland) during a 10-month period. After final fixation, according to the manufactures' technique guide and control of implant placement in the two common perpendicular 2D-fluoroscopic images (postero-anterior and true lateral), an additional tangential view and intraoperative 3D fluoroscopic scan were performed to control the anatomic fracture reduction and screw placements. Intraoperative revision rates due to screw misplacements (intra-articular or overlength) were evaluated. Additionally, the number of surgeons, time and radiation-exposure, for each step of the operating procedure, were recorded. In the standard 2D-fluoroscopic views (postero-anterior and true lateral projection), 22 screw misplacements of 232 inserted screws were not detected. Based on the additional tangential view, 12 screws were exchanged, followed by further 10 screws after performing the 3D fluoroscopic scan. The most lateral screw position had the highest risk for screw misplacement (accounting for 45.5% of all exchanged screws). The mean number of images for the tangential view was 3 ± 2.5 images. The mean surgical time was extended by 10.02 ± 3.82 minutes for the 3D fluoroscopic scan. An additional radiation exposure of 4.4 ± 4.5seconds, with a dose area product of 39.2 ± 14.5 cGy/cm(2) were necessary for the tangential view and 54.4 ± 20.9 seconds with a dose area product of 2.1 ± 2.2 cGy/cm(2), for the 3D fluoroscopic scan. We recommend the additional 2D-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. The use of intraoperative 3D fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consuming procedure, with a limited image quality so far.
- 20 June 2015
- Published by Medknow in Archives of Trauma Research
- Vol. 4 (2) , e24622
Open AccessTangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures
Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, while the penetration of the contralateral bone surface may result in tendon irritations and ruptures. The intraoperative control of fracture reduction and implant positioning is limited in the common postero-anterior and true lateral two-dimensional (2D)-fluoroscopic views. Therefore, additional 2D-fluoroscopic views in different projections and intraoperative three-dimensional (3D) fluoroscopy were recently reported. Nevertheless, their utility has issued controversies. The following questions should be answered in this study; 1) Are the additional tangential view and the intraoperative 3D fluoroscopy useful in the clinical routine to detect persistent fracture dislocations and screw misplacements, to prevent revision surgery? 2) Which is the most dangerous plate hole for screw misplacement? A total of 48 patients (36 females and 13 males) with 49 unstable distal radius fractures (22 x 23 A; 2 x 23 B, and 25 x 23 C) were treated with a 2.4 mm variable angle LCP Two-Column volar distal radius plate (Synthes GmbH, Oberdorf, Switzerland) during a 10-month period. After final fixation, according to the manufactures' technique guide and control of implant placement in the two common perpendicular 2D-fluoroscopic images (postero-anterior and true lateral), an additional tangential view and intraoperative 3D fluoroscopic scan were performed to control the anatomic fracture reduction and screw placements. Intraoperative revision rates due to screw misplacements (intra-articular or overlength) were evaluated. Additionally, the number of surgeons, time and radiation-exposure, for each step of the operating procedure, were recorded. In the standard 2D-fluoroscopic views (postero-anterior and true lateral projection), 22 screw misplacements of 232 inserted screws were not detected. Based on the additional tangential view, 12 screws were exchanged, followed by further 10 screws after performing the 3D fluoroscopic scan. The most lateral screw position had the highest risk for screw misplacement (accounting for 45.5% of all exchanged screws). The mean number of images for the tangential view was 3 ± 2.5 images. The mean surgical time was extended by 10.02 ± 3.82 minutes for the 3D fluoroscopic scan. An additional radiation exposure of 4.4 ± 4.5seconds, with a dose area product of 39.2 ± 14.5 cGy/cm(2) were necessary for the tangential view and 54.4 ± 20.9 seconds with a dose area product of 2.1 ± 2.2 cGy/cm(2), for the 3D fluoroscopic scan. We recommend the additional 2D-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. The use of intraoperative 3D fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consuming procedure, with a limited image quality so far.
- 26 November 2014
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 16 (4) , 330-340
Mit Marknagelimplantation assoziierte Frakturen
- 26 November 2014
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 16 (4) , 330-340
Mit Marknagelimplantation assoziierte Frakturen
- 25 April 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (8) , 1705-1710
A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
The purpose of this study was to investigate whether cement-augmented screw osteosynthesis results in stability comparable to conventional fixed-angle locking plate osteosynthesis using cadaveric bones to model a Sanders type 2B fracture. Seven pairs of fresh frozen human calcanei and the corresponding tali were used. The specimens were assigned pairwise to two study groups in a randomised manner. In order to determine the initial quasi-static stiffness of the bone-implant construct, testing commenced with quasi-static compression ramp loading; subsequently, sinusoidal cyclic compression loading at 2 Hz was performed until construct failure occurred. Initial dynamic stiffness (cycle 1), range of motion (ROM), cycles to failure and load to failure were determined from the machine data during the cyclic test. In addition, at 250-cycle intervals, Böhler’s angle and the critical angle of Gissane were determined on mediolateral X-rays shot with a triggered C-arm; 5° angle flattening was arbitrarily defined as a failure criterion. Bone mineral density was normally distributed without significant differences between the groups. The augmented screw osteosynthesis resulted in higher stiffness values compared to the fixed-angle locking plate osteosynthesis. The fracture fragment motion in the locking plate group was significantly higher compared to the group with augmented screw osteosynthesis. The results of this study indicate that in our selected test set-up augmented screw osteosynthesis was significantly superior to the conventional fixed-angle locking plate osteosynthesis with respect to primary stability and ROM during cyclic testing.
- 25 April 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (8) , 1705-1710
A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
The purpose of this study was to investigate whether cement-augmented screw osteosynthesis results in stability comparable to conventional fixed-angle locking plate osteosynthesis using cadaveric bones to model a Sanders type 2B fracture. Seven pairs of fresh frozen human calcanei and the corresponding tali were used. The specimens were assigned pairwise to two study groups in a randomised manner. In order to determine the initial quasi-static stiffness of the bone-implant construct, testing commenced with quasi-static compression ramp loading; subsequently, sinusoidal cyclic compression loading at 2 Hz was performed until construct failure occurred. Initial dynamic stiffness (cycle 1), range of motion (ROM), cycles to failure and load to failure were determined from the machine data during the cyclic test. In addition, at 250-cycle intervals, Böhler’s angle and the critical angle of Gissane were determined on mediolateral X-rays shot with a triggered C-arm; 5° angle flattening was arbitrarily defined as a failure criterion. Bone mineral density was normally distributed without significant differences between the groups. The augmented screw osteosynthesis resulted in higher stiffness values compared to the fixed-angle locking plate osteosynthesis. The fracture fragment motion in the locking plate group was significantly higher compared to the group with augmented screw osteosynthesis. The results of this study indicate that in our selected test set-up augmented screw osteosynthesis was significantly superior to the conventional fixed-angle locking plate osteosynthesis with respect to primary stability and ROM during cyclic testing.
- Open Access
- 23 August 2013
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 7 (1) , 217
Adjustment of traumatic femur shortening assisted by an intramedullar skeletal kinetic distractor: a case report
Distal comminuted femoral fractures with joint involvement are highly challenging for the surgeon. We present a potential therapeutic concept that aims especially at the treatment of posttraumatic leg length discrepancy.
- 23 August 2013
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 7 (1) , 217
Open AccessAdjustment of traumatic femur shortening assisted by an intramedullar skeletal kinetic distractor: a case report
Distal comminuted femoral fractures with joint involvement are highly challenging for the surgeon. We present a potential therapeutic concept that aims especially at the treatment of posttraumatic leg length discrepancy.
- Open Access
- 10 June 2013
- Published by Medknow in Archives of Trauma Research
- Vol. 2 (1) , 11-5
Utility of the Cortical Thickness of the Distal Radius as a Predictor of Distal-Radius Bone Density
Utility of the Cortical Thickness of the Distal Radius as a Predictor of Distal-Radius Bone Density - Archives of Trauma Research - - Kowsar
- 10 June 2013
- Published by Medknow in Archives of Trauma Research
- Vol. 2 (1) , 11-5
Open AccessUtility of the Cortical Thickness of the Distal Radius as a Predictor of Distal-Radius Bone Density
Utility of the Cortical Thickness of the Distal Radius as a Predictor of Distal-Radius Bone Density - Archives of Trauma Research - - Kowsar
- 17 February 2013
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 133 (5) , 627-633
Percutaneous navigated screw fixation of glenoid fractures
Open or percutaneous arthroscopic-based procedures are reported to fix unstable or displaced intra-articular glenoid fractures. Approach related morbidity has to be considered for open procedures, and arthroscopic-based procedures are demanding. Therefore an alternative percutaneous navigated approach is described. In an experimental setting an operative workflow was simulated to evaluate the best position of the patient on the operation table, the operating room set up and the fixation technique for the dynamic reference base of the navigation system. Based on two clinical cases, screw fixation of glenoid fractures via a posterior percutaneous approach is described, using a 2D-fluoroscopic based navigation system. Compared to the common approaches, the advantages and disadvantages of this procedure are discussed. The described technique of percutaneous navigated screw fixation of glenoid fractures is an alternative minimal invasive procedure. A reduction of approach related morbidity and more rapid return to function could be expected. The intraoperative results and postoperative functional outcome of both cases are promising.
- 17 February 2013
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 133 (5) , 627-633
Percutaneous navigated screw fixation of glenoid fractures
Open or percutaneous arthroscopic-based procedures are reported to fix unstable or displaced intra-articular glenoid fractures. Approach related morbidity has to be considered for open procedures, and arthroscopic-based procedures are demanding. Therefore an alternative percutaneous navigated approach is described. In an experimental setting an operative workflow was simulated to evaluate the best position of the patient on the operation table, the operating room set up and the fixation technique for the dynamic reference base of the navigation system. Based on two clinical cases, screw fixation of glenoid fractures via a posterior percutaneous approach is described, using a 2D-fluoroscopic based navigation system. Compared to the common approaches, the advantages and disadvantages of this procedure are discussed. The described technique of percutaneous navigated screw fixation of glenoid fractures is an alternative minimal invasive procedure. A reduction of approach related morbidity and more rapid return to function could be expected. The intraoperative results and postoperative functional outcome of both cases are promising.
- 13 February 2013
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 15 (1) , 6-16
Mit Marknagelimplantation assoziierte Frakturen
- 13 February 2013
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 15 (1) , 6-16
Mit Marknagelimplantation assoziierte Frakturen