A Method of Flexible Micro-Wire Electrode Insertion in Rodent for Chronic Neural Recording and a Device for Electrode Insertion
- 31 July 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 27 (9) , 1724-1731
Abstract
Reliable chronic neural recording from focal deep brain structures is impeded by insertion injury and foreign body response, the magnitude of which is correlated with the mechanical mismatch between the electrode and tissue. Thin and flexible electrodes cause less glial scarring and record longer than stiff electrodes. However, the insertion of flexible microelectrodes in brain has been a challenge. Here, a novel insertion method is proposed, and demonstrated, for precise targeting deep brain structures using flexible micro-wire electrodes. The microelectrode is spun and slowly inserted in brain through an appropriate electrode guide. The electrode guide does not penetrate into cortex. Based on two new mechanisms, namely spinning and guided insertion, we have demonstrated successful insertion of 25 micron platinum flexible electrodes about 10 mm deep in rat brains without buckling. We present an electrode insertion device based on the proposed method and demonstrate its use to implant flexible microelectrodes in rat brains. The step-by-step insertion process is described. Microelectrodes were inserted in the Bötzinger complex and respiratory neural activity was recorded acutely in 9 rats and chronically in 2 rats for 50 days.Keywords
This publication has 37 references indexed in Scilit:
- The density difference between tissue and neural probes is a key factor for glial scarringScientific Reports, 2013
- Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfacesNature Materials, 2012
- Changes in emotional state modulate neuronal firing rates of human speech motor cortex: A case study in long-term recordingNeurocase, 2011
- In VivoPenetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer ScalesIEEE Transactions on Biomedical Engineering, 2008
- Brain waves reveal intensity of painNature, 2007
- The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skullJournal of Biomedical Materials Research Part A, 2007
- In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortexIEEE Transactions on Biomedical Engineering, 2006
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005
- Brain–machine interfaces to restore motor function and probe neural circuitsNature Reviews Neuroscience, 2003
- Expiratory neurons of the bötzinger complex in the rat: A morphological study following intracellular labeling with biocytinJournal of Comparative Neurology, 1993