Abstract
A dynamic model of a battery is required for the appropriate real-time control during charging/discharging process. Present paper considers the development of nonlinear Dynamic Equivalent Electric Circuit Model (DEECM) of a Valve Regulated Lead-Acid (VRLA) battery based on the data obtained through the experimentation and the available datasheet information. Cases of charging, discharging, and the self-discharging are considered for 12V, 26Ah VRLA battery at room temperature. Accordingly, experimental v-i characteristics of the battery are used to express the nonlinear model parameters as a function of measurable battery current and estimated open-circuit voltage as a part of parameter estimation. Further model is validated through voltage response test with maximum error of 0.4% during discharging and 0.6% during charging under different current levels.
Funding Information
  • Ministry of Electronics and Information technology (MLA/MUM/GA/10(20))
  • Anusandhan National Research Foundation (ECR/2016/002029)

This publication has 20 references indexed in Scilit: