Madhuri Avinash Chaudhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Madhuri Avinash Chaudhari has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Chaitanya N. Jibhakate
Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India
3 shared publications - Ritesh Kumar Keshri
Visvesvaraya National Institute of Technology
3 shared publications - Sandhya Lavety
Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India
3 shared publications Akhil Manoj Shende
Visvesvaraya National Institute of Technology,Electrical Engineering Department,Nagpur,India
2 shared publications- K S Raja Sekhar
Electrical Engineering Department, Visvesvaraya National Institute of Technology, Nagpur, India
2 shared publications - Mohan Renge
RCOEM
2 shared publications
Latest Publications
- 20 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 19 (4) , 1109-1120
Decentralized Agent Based Real-Time Energy Management Framework for Hybrid Low-Voltage Multimicrogrid System
The advancement of smart technology promotes interactive operation among the microgrid (MG) systems with the integration of the renewable energy sources (RES) and battery energy storage systems (BESS). Due to the stochastic characteristics of RES and demand, the real-time monitoring operations in multi-MG system are becoming crucial task for stable and reliable electricity to fulfil the load demand. This article proposes agent-based real-time energy management framework for a low-voltage hybrid multi-MG system with integration of RES and BESS. The main objectives of the proposed method are to manage the power flow effectively, coordinate and exchange energy within the multi-MG and ac grid to improve the overall efficiency and reliability. Multiagents coordinate RES, BESS, and load, and effectively handles the energy management operation during fluctuating load demand. To showcase the effectiveness of the proposed scheme, different scenarios with test cases are demonstrated for the operation of the maximum RES utilization, power exchange within the MG systems and ac grid. This method ensures the dc bus voltage regulation and the power balance during all scenarios. A multi-MG system is configured with a 48 V DC bus, comprising four MGs rated at 1.8, 1.8, 2.9, and 5.1 kW, respectively. A multi-MG system is developed and simulated in MATLAB/Simulink. The real-time simulator results validated effectiveness and reliability of the proposed method with OPAL-RT OP4610.
- 20 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 19 (4) , 1109-1120
Decentralized Agent Based Real-Time Energy Management Framework for Hybrid Low-Voltage Multimicrogrid System
The advancement of smart technology promotes interactive operation among the microgrid (MG) systems with the integration of the renewable energy sources (RES) and battery energy storage systems (BESS). Due to the stochastic characteristics of RES and demand, the real-time monitoring operations in multi-MG system are becoming crucial task for stable and reliable electricity to fulfil the load demand. This article proposes agent-based real-time energy management framework for a low-voltage hybrid multi-MG system with integration of RES and BESS. The main objectives of the proposed method are to manage the power flow effectively, coordinate and exchange energy within the multi-MG and ac grid to improve the overall efficiency and reliability. Multiagents coordinate RES, BESS, and load, and effectively handles the energy management operation during fluctuating load demand. To showcase the effectiveness of the proposed scheme, different scenarios with test cases are demonstrated for the operation of the maximum RES utilization, power exchange within the MG systems and ac grid. This method ensures the dc bus voltage regulation and the power balance during all scenarios. A multi-MG system is configured with a 48 V DC bus, comprising four MGs rated at 1.8, 1.8, 2.9, and 5.1 kW, respectively. A multi-MG system is developed and simulated in MATLAB/Simulink. The real-time simulator results validated effectiveness and reliability of the proposed method with OPAL-RT OP4610.
- 26 March 2025
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 26 (5) , 967-979
Real-time impact study of 2-wheeler EV charging on the distribution network
Transportation is vital for modern societies, facilitating daily commutes and the movement of goods, but it is also a major contributor to pollution, second only to industrial emissions. While electric vehicles (EVs) offer a greener alternative, their charging demands-affected by factors such as vehicle type, location, battery state of charge (SoC), and charging rate (C-Rate) can place additional strain on power distribution networks and introduce non-linear loads, impacting network stability. This study investigates the effects of EV charging on the distribution network, focusing on changes in voltage, current, and total harmonic distortion (THD) at the point of common coupling (PCC). Using MATLAB environment, a 10 kVA single-phase distribution network was designed with various realistic loads, and EVs were modeled as rectifier-converter systems to assess their impact. The integration of EVs into the network is considered by taking variation with respect to changes in its location, battery SoCs and C-Rate at the time of charging. The research also examines the real-time impact of two-wheeler EVs, such as Bajaj Chetak, OLA S1-Pro, Okinawa, and Tunwal Lithino Li, with a focus on harmonic distortion injected in the grid current. The harmonic distortion events were captured via HIOKI PW-3900 Power Quality Meter (PQM). The findings provide useful insights for future decision-making regarding EV integration into power distribution networks.
- 26 March 2025
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 26 (5) , 967-979
Real-time impact study of 2-wheeler EV charging on the distribution network
Transportation is vital for modern societies, facilitating daily commutes and the movement of goods, but it is also a major contributor to pollution, second only to industrial emissions. While electric vehicles (EVs) offer a greener alternative, their charging demands-affected by factors such as vehicle type, location, battery state of charge (SoC), and charging rate (C-Rate) can place additional strain on power distribution networks and introduce non-linear loads, impacting network stability. This study investigates the effects of EV charging on the distribution network, focusing on changes in voltage, current, and total harmonic distortion (THD) at the point of common coupling (PCC). Using MATLAB environment, a 10 kVA single-phase distribution network was designed with various realistic loads, and EVs were modeled as rectifier-converter systems to assess their impact. The integration of EVs into the network is considered by taking variation with respect to changes in its location, battery SoCs and C-Rate at the time of charging. The research also examines the real-time impact of two-wheeler EVs, such as Bajaj Chetak, OLA S1-Pro, Okinawa, and Tunwal Lithino Li, with a focus on harmonic distortion injected in the grid current. The harmonic distortion events were captured via HIOKI PW-3900 Power Quality Meter (PQM). The findings provide useful insights for future decision-making regarding EV integration into power distribution networks.
- 3 July 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 235
Impact of PLL and non-PLL vector current control techniques on grid connected inverter
- 3 July 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 235
Impact of PLL and non-PLL vector current control techniques on grid connected inverter
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (4) , 2634-2646
Enhanced Hybrid Converter Topology for PV-Grid-EV Integration
Due to the continuous price reductions in PV mod- ules and significant development in electric vehicles (EV), the integration of solar photovoltaic (PV) into the EV charging system has been inevitable. This paper proposes the control of a hybrid converter in a EV charging station. This system consists of a PV fed Enhanced Hybrid Converter (EHC) integrated with a single-phase grid. The control of the EHC to perceive maximum power from PV, dc voltage regulation for EV charging and AC power control for feeding the AC grid is presented. A testbed under different circumstances i.e., AC and DC power distribution from the solar PV under different insolation conditions, feeding PV power to grid under the absence of EV, feeding PV power to EV charging port in the absence of grid and feeding EV power to grid under the absence of PV power is developed under MATLAB/Simulink environment for validation. Also, a switching logic is proposed for the operation of the EHC converter under no-load condition. The hardware prototype is developed with TI F28379D processor in the laboratory has validated the proposed EHC on various conditions.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (4) , 2634-2646
Enhanced Hybrid Converter Topology for PV-Grid-EV Integration
Due to the continuous price reductions in PV mod- ules and significant development in electric vehicles (EV), the integration of solar photovoltaic (PV) into the EV charging system has been inevitable. This paper proposes the control of a hybrid converter in a EV charging station. This system consists of a PV fed Enhanced Hybrid Converter (EHC) integrated with a single-phase grid. The control of the EHC to perceive maximum power from PV, dc voltage regulation for EV charging and AC power control for feeding the AC grid is presented. A testbed under different circumstances i.e., AC and DC power distribution from the solar PV under different insolation conditions, feeding PV power to grid under the absence of EV, feeding PV power to EV charging port in the absence of grid and feeding EV power to grid under the absence of PV power is developed under MATLAB/Simulink environment for validation. Also, a switching logic is proposed for the operation of the EHC converter under no-load condition. The hardware prototype is developed with TI F28379D processor in the laboratory has validated the proposed EHC on various conditions.
- 1 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault-Tolerant Operation of 3-Phase 7-Level CHBMLI with Modified Neutral Point Shift Method
Multilevel inverters(MLI) are now widely used in industrial and domestic applications. The multilevel inverter improves the voltage quality compared with the conventional inverter. However, due to the presence of more components, MLI is less reliable. Even fault in a single switch could lead to unbalance of output line voltages. This paper discusses the fault-tolerant operation of Cascaded H - Bridge (CHB) Multilevel Inverter with modified neutral point shift (NPS) technique. If there is a fault in any cells of CHB, it is bypassed and then the NPS technique is implemented to tolerate the fault. Bypassing the faulty cellto isolateit that will not contribute to theoutput; hence it can be later removed for maintenance. It allows the operation to be continued rather than completely shutting down the operation. But after NPS implementation the voltage is balanced but less than that of a healthy system. This paper presents a modified NPS technique, which maintains MLI output voltages at pre-fault conditions. In this paper, fault-tolerant control technique is presented with its mathematical modeling. This modeling is implemented in MATLAB/Simulink for 3-phase CHB. Faults at various cells are created to verify the performance of the system.
- 1 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault-Tolerant Operation of 3-Phase 7-Level CHBMLI with Modified Neutral Point Shift Method
Multilevel inverters(MLI) are now widely used in industrial and domestic applications. The multilevel inverter improves the voltage quality compared with the conventional inverter. However, due to the presence of more components, MLI is less reliable. Even fault in a single switch could lead to unbalance of output line voltages. This paper discusses the fault-tolerant operation of Cascaded H - Bridge (CHB) Multilevel Inverter with modified neutral point shift (NPS) technique. If there is a fault in any cells of CHB, it is bypassed and then the NPS technique is implemented to tolerate the fault. Bypassing the faulty cellto isolateit that will not contribute to theoutput; hence it can be later removed for maintenance. It allows the operation to be continued rather than completely shutting down the operation. But after NPS implementation the voltage is balanced but less than that of a healthy system. This paper presents a modified NPS technique, which maintains MLI output voltages at pre-fault conditions. In this paper, fault-tolerant control technique is presented with its mathematical modeling. This modeling is implemented in MATLAB/Simulink for 3-phase CHB. Faults at various cells are created to verify the performance of the system.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Tolerant Si-SiC based Hybrid Modular Multilevel Converter with Enhanced Efficiency
Conventional Modular Multilevel Converter (MMC) consisting of only Half-Bridge Sub Module (HB-SM) offers scalability, modularity, flexibility, and lower losses as compared to multilevel converters. However, it lacks to provide DC fault-tolerant capability in High Voltage Direct Current (HVDC) applications. This paper proposes a Silicon-Silicon Carbide (Si-SiC) based Hybrid MMC, called as Fault Tolerant MMC (FTMMC), consisting of SiC based HB-SM and Si based Full-Bridge Sub Module (FB-SM), that provides DC fault-tolerant capability with enhanced efficiency for HVDC applications. In this paper, a control technique is used, resulting in FB-SM switching at the fundamental frequency and HB-SM switching at a significantly higher switching frequency. The FB-SM is controlled using the Nearest Level Control (NLC) modulation approach, while the HB-SM is controlled using a combination of NLC method and Phase Disposition Pulse Width Modulation (PDPWM) technique. Since the switching frequency of the HB-SM is significantly higher than the FB-SM, SiC switches are used in HB-SM to minimize the switching losses and to optimize the cost of the system. This is because SiC switches have lower switching losses and higher cost than Si switches. Furthermore, for voltage balancing of the FB-SM and the HB-SM, the Reduced Switching Frequency (RSF) technique is used, which decreases the switching frequency of each SM and therefore minimizes the overall switching loss of the FTMMC. To evaluate the effectiveness of the proposed converter topology and its control technique, simulation of the FTMMC is performed in MATLAB Simulink. The power loss of FTMMC is analytically calculated and compared with the existing solutions to prove its efficiency.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Tolerant Si-SiC based Hybrid Modular Multilevel Converter with Enhanced Efficiency
Conventional Modular Multilevel Converter (MMC) consisting of only Half-Bridge Sub Module (HB-SM) offers scalability, modularity, flexibility, and lower losses as compared to multilevel converters. However, it lacks to provide DC fault-tolerant capability in High Voltage Direct Current (HVDC) applications. This paper proposes a Silicon-Silicon Carbide (Si-SiC) based Hybrid MMC, called as Fault Tolerant MMC (FTMMC), consisting of SiC based HB-SM and Si based Full-Bridge Sub Module (FB-SM), that provides DC fault-tolerant capability with enhanced efficiency for HVDC applications. In this paper, a control technique is used, resulting in FB-SM switching at the fundamental frequency and HB-SM switching at a significantly higher switching frequency. The FB-SM is controlled using the Nearest Level Control (NLC) modulation approach, while the HB-SM is controlled using a combination of NLC method and Phase Disposition Pulse Width Modulation (PDPWM) technique. Since the switching frequency of the HB-SM is significantly higher than the FB-SM, SiC switches are used in HB-SM to minimize the switching losses and to optimize the cost of the system. This is because SiC switches have lower switching losses and higher cost than Si switches. Furthermore, for voltage balancing of the FB-SM and the HB-SM, the Reduced Switching Frequency (RSF) technique is used, which decreases the switching frequency of each SM and therefore minimizes the overall switching loss of the FTMMC. To evaluate the effectiveness of the proposed converter topology and its control technique, simulation of the FTMMC is performed in MATLAB Simulink. The power loss of FTMMC is analytically calculated and compared with the existing solutions to prove its efficiency.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Hybrid Modular Multilevel Converter based on Si and SiC Devices with Level Multiplier Circuit
This paper presents a Modular Multilevel Converter (MMC) variant that can obtain greater number of output voltage levels than the conventional MMC while using smaller number of Submodule (SM). It is called as Level Multiplier Circuit for MMC (LMMMC). It is a Hybrid MMC made up of Half-bridge Submodule (HB-SM) and Full-bridge Submodule (FB-SM). In comparison to the HB-SM cell, the FB-SM cell has a different voltage value. The number of FB-SMs connected in the arm determines the value of each FB-SM voltage. To achieve the same number of levels in the output voltage, LMMMC employs fewer semiconductor switches than the conventional MMC. The switching loss of the LMMMC increases because the switching frequency of FB-SM is significantly higher than the HB-SM. To compensate for this, Silicon Carbide (SiC) switches are utilized instead of Silicon (Si) switches in the FB-SM. This is due to the fact that SiC devices have lower switching losses than Si devices. The operational principle of LMMMC is described, as well as comparison of its power loss to that of a conventional MMC is presented. The conventional MMC and LMMMC models are simulated in MATLAB Simulink to verify the effectiveness of the proposed converter topology.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Hybrid Modular Multilevel Converter based on Si and SiC Devices with Level Multiplier Circuit
This paper presents a Modular Multilevel Converter (MMC) variant that can obtain greater number of output voltage levels than the conventional MMC while using smaller number of Submodule (SM). It is called as Level Multiplier Circuit for MMC (LMMMC). It is a Hybrid MMC made up of Half-bridge Submodule (HB-SM) and Full-bridge Submodule (FB-SM). In comparison to the HB-SM cell, the FB-SM cell has a different voltage value. The number of FB-SMs connected in the arm determines the value of each FB-SM voltage. To achieve the same number of levels in the output voltage, LMMMC employs fewer semiconductor switches than the conventional MMC. The switching loss of the LMMMC increases because the switching frequency of FB-SM is significantly higher than the HB-SM. To compensate for this, Silicon Carbide (SiC) switches are utilized instead of Silicon (Si) switches in the FB-SM. This is due to the fact that SiC devices have lower switching losses than Si devices. The operational principle of LMMMC is described, as well as comparison of its power loss to that of a conventional MMC is presented. The conventional MMC and LMMMC models are simulated in MATLAB Simulink to verify the effectiveness of the proposed converter topology.
- 16 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (6) , 6494-6503
Multistep Constant Current-Constant Voltage Charging Strategy for a Valve Regulated Lead-Acid Battery
This article investigates the evaluation of different charging patterns of multistep constant current-constant voltage (MSCC-CV) for fast charging of a valve regulated lead-acid battery for electric vehicles. In this article, four parameters are sensed and feedback for closed-loop operation, i.e., battery temperature, terminal voltage, state of charge (SOC), and time. The battery current is dynamically adjusted in response to these four parameters for three different charging patterns. The three charging patterns of MSCC-CV by controlling 1) SOC and temperature, 2) the terminal voltage, SOC, and maintained temperature, and 3) the charging time and SOC. Further work is carried out to investigate the effects of charging strategies on battery health. As per the experimental results, it has been demonstrated that charging pattern with four-step by regulating battery terminal voltage, SOC, and maintained temperature shortens the charging time to 3.6 h as compared to conventional constant current-CV with improved battery life and health.
- 16 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (6) , 6494-6503
Multistep Constant Current-Constant Voltage Charging Strategy for a Valve Regulated Lead-Acid Battery
This article investigates the evaluation of different charging patterns of multistep constant current-constant voltage (MSCC-CV) for fast charging of a valve regulated lead-acid battery for electric vehicles. In this article, four parameters are sensed and feedback for closed-loop operation, i.e., battery temperature, terminal voltage, state of charge (SOC), and time. The battery current is dynamically adjusted in response to these four parameters for three different charging patterns. The three charging patterns of MSCC-CV by controlling 1) SOC and temperature, 2) the terminal voltage, SOC, and maintained temperature, and 3) the charging time and SOC. Further work is carried out to investigate the effects of charging strategies on battery health. As per the experimental results, it has been demonstrated that charging pattern with four-step by regulating battery terminal voltage, SOC, and maintained temperature shortens the charging time to 3.6 h as compared to conventional constant current-CV with improved battery life and health.
- 25 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2600-2611
Non-Linear Model and Parameter Extraction for Charge/Discharge Behavior of Valve Regulated Lead-Acid Battery
A dynamic model of a battery is required for the appropriate real-time control during charging/discharging process. Present paper considers the development of nonlinear Dynamic Equivalent Electric Circuit Model (DEECM) of a Valve Regulated Lead-Acid (VRLA) battery based on the data obtained through the experimentation and the available datasheet information. Cases of charging, discharging, and the self-discharging are considered for 12V, 26Ah VRLA battery at room temperature. Accordingly, experimental v-i characteristics of the battery are used to express the nonlinear model parameters as a function of measurable battery current and estimated open-circuit voltage as a part of parameter estimation. Further model is validated through voltage response test with maximum error of 0.4% during discharging and 0.6% during charging under different current levels.
- 25 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2600-2611
Non-Linear Model and Parameter Extraction for Charge/Discharge Behavior of Valve Regulated Lead-Acid Battery
A dynamic model of a battery is required for the appropriate real-time control during charging/discharging process. Present paper considers the development of nonlinear Dynamic Equivalent Electric Circuit Model (DEECM) of a Valve Regulated Lead-Acid (VRLA) battery based on the data obtained through the experimentation and the available datasheet information. Cases of charging, discharging, and the self-discharging are considered for 12V, 26Ah VRLA battery at room temperature. Accordingly, experimental v-i characteristics of the battery are used to express the nonlinear model parameters as a function of measurable battery current and estimated open-circuit voltage as a part of parameter estimation. Further model is validated through voltage response test with maximum error of 0.4% during discharging and 0.6% during charging under different current levels.
- Open Access
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 164747-164761
Evaluation of Charging Strategies for Valve Regulated Lead-Acid Battery
The present paper considers the evaluation of temperature regulated and unregulated charging strategies to select the appropriate one to ensure extended battery life with reduced charging time. Temperature regulated pulse charging (TRPC) and temperature regulated reflex charging (TRRC) are compared with the Constant current–constant voltage (CC-CV) charging strategy. In the case of CC-CV charging temperature of the battery rises with the magnitude of the current being injected and cannot be regulated without any external cooling arrangement. Impact on the State of health (SOH) and the expected lifespan of the battery are considered as the parameters of evaluation. Temperature regulated strategies are implemented through a discrete electro-thermal model, which acts as a temperature estimator. The co-efficient of the estimators corresponds to the battery parameters such as internal resistance and thermal time constants, entropy, etc. Temperature regulation is ensured in the three identified sections of charge deposited vs magnitude of the injected current. Three sections are identified as sections where the injected current is not sufficient to raise the battery temperature to set limit or not and the level of charge submitted as compared to normal charging. Experimentation is carried with 12 V, 26 Ah Valve regulated lead-acid battery to justify that increase in temperature reference of regulation allows submission of higher charge for the same charging rate. It is demonstrated that TRPC results in a significant reduction (≈60%) in charging time as compared to CC-CV and TRRC. For the same charging time as achieved with TRPC, TRPC results in almost double the expected life of operation and better SOH as compared to CC-CV and TRRC.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 164747-164761
Open AccessEvaluation of Charging Strategies for Valve Regulated Lead-Acid Battery
The present paper considers the evaluation of temperature regulated and unregulated charging strategies to select the appropriate one to ensure extended battery life with reduced charging time. Temperature regulated pulse charging (TRPC) and temperature regulated reflex charging (TRRC) are compared with the Constant current–constant voltage (CC-CV) charging strategy. In the case of CC-CV charging temperature of the battery rises with the magnitude of the current being injected and cannot be regulated without any external cooling arrangement. Impact on the State of health (SOH) and the expected lifespan of the battery are considered as the parameters of evaluation. Temperature regulated strategies are implemented through a discrete electro-thermal model, which acts as a temperature estimator. The co-efficient of the estimators corresponds to the battery parameters such as internal resistance and thermal time constants, entropy, etc. Temperature regulation is ensured in the three identified sections of charge deposited vs magnitude of the injected current. Three sections are identified as sections where the injected current is not sufficient to raise the battery temperature to set limit or not and the level of charge submitted as compared to normal charging. Experimentation is carried with 12 V, 26 Ah Valve regulated lead-acid battery to justify that increase in temperature reference of regulation allows submission of higher charge for the same charging rate. It is demonstrated that TRPC results in a significant reduction (≈60%) in charging time as compared to CC-CV and TRRC. For the same charging time as achieved with TRPC, TRPC results in almost double the expected life of operation and better SOH as compared to CC-CV and TRRC.