Abstract
In high-dimensional magnetic resonance imaging applications, time-consuming, sequential acquisition of data samples in the spatial frequency domain (k-space) can often be accelerated by accounting for dependencies in linear reconstruction, at the cost of noise amplification that depends on the sampling pattern. Common examples are support-constrained, parallel, and dynamic MRI, and k-space sampling strategies are primarily driven by image-domain metrics that are expensive to compute for arbitrary sampling patterns. It remains challenging to provide systematic and computationally efficient automatic designs of arbitrary multidimensional Cartesian sampling patterns that mitigate noise amplification, given the subspace to which the object is confined. To address this problem, this paper introduces a theoretical framework that describes local geometric properties of the sampling pattern and relates them to the spread in the eigenvalues of the information matrix described by its first two spectral moments. This new criterion is then used for very efficient optimization of complex multidimensional sampling patterns that does not require reconstructing images or explicitly mapping noise amplification. Experiments with in vivo data show strong agreement between this criterion and traditional, comprehensive image-domain- and k-space-based metrics, indicating the potential of the approach for computationally efficient (on-the-fly), automatic, and adaptive design of sampling patterns.Keywords
All Related Versions
Funding Information
- NIH (P41 EB015891, R01 EB017739)
This publication has 30 references indexed in Scilit:
- Rapid Pediatric Cardiac Assessment of Flow and Ventricular Volume With Compressed Sensing Parallel Imaging Volumetric Cine Phase-Contrast MRIAmerican Journal of Roentgenology, 2012
- Differential domain analysis for non-uniform samplingACM Transactions on Graphics, 2011
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- Comprehensive quantification of signal‐to‐noise ratio and g‐factor for image‐based and k‐space‐based parallel imaging reconstructionsMagnetic Resonance in Medicine, 2008
- On optimality of parallel MRI reconstruction in k‐spaceMagnetic Resonance in Medicine, 2007
- Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)Magnetic Resonance in Medicine, 2006
- Convergence behavior of iterative SENSE reconstruction with non‐Cartesian trajectoriesMagnetic Resonance in Medicine, 2005
- Spatiotemporal reconstruction of list-mode PET dataIEEE Transactions on Medical Imaging, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Spectrally optimal sampling for distribution ray tracingACM SIGGRAPH Computer Graphics, 1991