Evan Levine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Evan Levine has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Brian Hargreaves
Department of Electrical Engineering and Radiology, Stanford University, Stanford, California, USA
2 shared publications- Brian A. Hargreaves
Stanford University Stanford University Stanford University Stanford University Stanford University
1 shared publication Bruce Daniel
Lucas Center, Departments of Electrical Engineering and Radiology, Stanford University, Stanford, California, USA
1 shared publication- Can Chen
Canon USA, Inc, United States
1 shared publication Christopher Beaulieu
Department of Electrical Engineering and Radiology, Stanford University, Stanford, California, USA
1 shared publicationFrancisco Imai
Canon USA, Inc, United States
1 shared publication
Latest Publications
- 24 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (2) , 557-567
On-the-Fly Adaptive ${k}$ -Space Sampling for Linear MRI Reconstruction Using Moment-Based Spectral AnalysisIn high-dimensional magnetic resonance imaging applications, time-consuming, sequential acquisition of data samples in the spatial frequency domain (k-space) can often be accelerated by accounting for dependencies in linear reconstruction, at the cost of noise amplification that depends on the sampling pattern. Common examples are support-constrained, parallel, and dynamic MRI, and k-space sampling strategies are primarily driven by image-domain metrics that are expensive to compute for arbitrary sampling patterns. It remains challenging to provide systematic and computationally efficient automatic designs of arbitrary multidimensional Cartesian sampling patterns that mitigate noise amplification, given the subspace to which the object is confined. To address this problem, this paper introduces a theoretical framework that describes local geometric properties of the sampling pattern and relates them to the spread in the eigenvalues of the information matrix described by its first two spectral moments. This new criterion is then used for very efficient optimization of complex multidimensional sampling patterns that does not require reconstructing images or explicitly mapping noise amplification. Experiments with in vivo data show strong agreement between this criterion and traditional, comprehensive image-domain- and k-space-based metrics, indicating the potential of the approach for computationally efficient (on-the-fly), automatic, and adaptive design of sampling patterns.
- 24 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (2) , 557-567
On-the-Fly Adaptive ${k}$ -Space Sampling for Linear MRI Reconstruction Using Moment-Based Spectral AnalysisIn high-dimensional magnetic resonance imaging applications, time-consuming, sequential acquisition of data samples in the spatial frequency domain (k-space) can often be accelerated by accounting for dependencies in linear reconstruction, at the cost of noise amplification that depends on the sampling pattern. Common examples are support-constrained, parallel, and dynamic MRI, and k-space sampling strategies are primarily driven by image-domain metrics that are expensive to compute for arbitrary sampling patterns. It remains challenging to provide systematic and computationally efficient automatic designs of arbitrary multidimensional Cartesian sampling patterns that mitigate noise amplification, given the subspace to which the object is confined. To address this problem, this paper introduces a theoretical framework that describes local geometric properties of the sampling pattern and relates them to the spread in the eigenvalues of the information matrix described by its first two spectral moments. This new criterion is then used for very efficient optimization of complex multidimensional sampling patterns that does not require reconstructing images or explicitly mapping noise amplification. Experiments with in vivo data show strong agreement between this criterion and traditional, comprehensive image-domain- and k-space-based metrics, indicating the potential of the approach for computationally efficient (on-the-fly), automatic, and adaptive design of sampling patterns.
- 7 July 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (3) , 1495-1505
Accelerated three‐dimensional multispectral MRI with robust principal component analysis for separation of on‐ and off‐resonance signals
Purpose: To enable highly accelerated distortion‐free MRI near metal by separating on‐ and off‐resonance to exploit the redundancy of slice‐phase encoding for the dominant on‐resonance component.Methods: Multispectral MRI techniques resolve off‐resonance distortions by a combination of limited excitation bins and additional encoding. Inspired by robust principal component analysis, a novel compact representation of multispectral images as a sum of rank‐one and sparse matrices corresponding to on‐ and off‐resonance respectively is described. This representation is used in a calibration‐free and model‐free reconstruction for data with an undersampling pattern that varies between bins. Retrospective undersampling was used to compare the proposed reconstruction and bin‐by‐bin compressed sensing. Hip images were acquired in eight patients with standard and prospectively undersampled three‐dimensional multispectral imaging, and image quality was evaluated by two radiologists on a 5‐point scale.Results: Experiments with retrospective undersampling showed that the enhanced sparsity afforded by the separation greatly reduces reconstruction errors and artifacts. Images from prospectively undersampled multispectral imaging offered 2.6–3.4‐fold (18–24‐fold overall) acceleration compared to standard multispectral imaging with parallel imaging and partial‐Fourier acceleration with equivalence in all qualitative assessments within a tolerance of one point (P < 0.004).Conclusion: Three‐dimensional multispectral imaging can be highly accelerated by varying undersampling between bins and separating on‐ and off‐resonance. Magn Reson Med 79:1495–1505, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 7 July 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (3) , 1495-1505
Accelerated three‐dimensional multispectral MRI with robust principal component analysis for separation of on‐ and off‐resonance signals
Purpose: To enable highly accelerated distortion‐free MRI near metal by separating on‐ and off‐resonance to exploit the redundancy of slice‐phase encoding for the dominant on‐resonance component.Methods: Multispectral MRI techniques resolve off‐resonance distortions by a combination of limited excitation bins and additional encoding. Inspired by robust principal component analysis, a novel compact representation of multispectral images as a sum of rank‐one and sparse matrices corresponding to on‐ and off‐resonance respectively is described. This representation is used in a calibration‐free and model‐free reconstruction for data with an undersampling pattern that varies between bins. Retrospective undersampling was used to compare the proposed reconstruction and bin‐by‐bin compressed sensing. Hip images were acquired in eight patients with standard and prospectively undersampled three‐dimensional multispectral imaging, and image quality was evaluated by two radiologists on a 5‐point scale.Results: Experiments with retrospective undersampling showed that the enhanced sparsity afforded by the separation greatly reduces reconstruction errors and artifacts. Images from prospectively undersampled multispectral imaging offered 2.6–3.4‐fold (18–24‐fold overall) acceleration compared to standard multispectral imaging with parallel imaging and partial‐Fourier acceleration with equivalence in all qualitative assessments within a tolerance of one point (P < 0.004).Conclusion: Three‐dimensional multispectral imaging can be highly accelerated by varying undersampling between bins and separating on‐ and off‐resonance. Magn Reson Med 79:1495–1505, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 1 January 2017
- Published by Optica Publishing Group
- p. DW4F.2
Challenges and solutions in 3D object capture: High-precision multi-view camera calibration using a rotating state; and 3D reconstruction of mirror-like objects using efficient ray coding
Two challenges in 3D capture are illustrated: highly precise multi-view camera calibration for precise pose estimation of cameras using a rotating stage and capture of mirror- type specular objects that lack own appearance and whose reflections from environment are view-dependent.
- 1 January 2017
- Published by Optica Publishing Group
- p. DW4F.2
Challenges and solutions in 3D object capture: High-precision multi-view camera calibration using a rotating state; and 3D reconstruction of mirror-like objects using efficient ray coding
Two challenges in 3D capture are illustrated: highly precise multi-view camera calibration for precise pose estimation of cameras using a rotating stage and capture of mirror- type specular objects that lack own appearance and whose reflections from environment are view-dependent.
- 21 April 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1774-1785
3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson‐disc sampling
Purpose: To enable robust, high spatio‐temporal‐resolution three‐dimensional Cartesian MRI using a scheme incorporating a novel variable density random k‐space sampling trajectory allowing flexible and retrospective selection of the temporal footprint with compressed sensing (CS).Methods: A complementary Poisson‐disc k‐space sampling trajectory was designed to allow view sharing and varying combinations of reduced view sharing with CS from the same prospective acquisition. These schemes were used for two‐point Dixon‐based dynamic contrast‐enhanced MRI (DCE‐MRI) of the breast and abdomen. Results were validated in vivo with a novel approach using variable‐flip‐angle data, which was retrospectively accelerated using the same methods but offered a ground truth.Results: In breast DCE‐MRI, the temporal footprint could be reduced 2.3‐fold retrospectively without introducing noticeable artifacts, improving depiction of rapidly enhancing lesions. Further, experiments with variable‐flip‐angle data showed that reducing view sharing improved accuracy in reconstruction and T1 mapping. In abdominal MRI, 2.3‐fold and 3.6‐fold reductions in temporal footprint allowed reduced motion artifacts.Conclusion: The complementary‐Poisson‐disc k‐space sampling trajectory allowed a retrospective spatiotemporal resolution tradeoff using CS and view sharing, imparting robustness to motion and contrast enhancement. The technique was also validated using a novel approach of fully acquired variable‐flip‐angle acquisition. Magn Reson Med 77:1774–1785, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- 21 April 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1774-1785
3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson‐disc sampling
Purpose: To enable robust, high spatio‐temporal‐resolution three‐dimensional Cartesian MRI using a scheme incorporating a novel variable density random k‐space sampling trajectory allowing flexible and retrospective selection of the temporal footprint with compressed sensing (CS).Methods: A complementary Poisson‐disc k‐space sampling trajectory was designed to allow view sharing and varying combinations of reduced view sharing with CS from the same prospective acquisition. These schemes were used for two‐point Dixon‐based dynamic contrast‐enhanced MRI (DCE‐MRI) of the breast and abdomen. Results were validated in vivo with a novel approach using variable‐flip‐angle data, which was retrospectively accelerated using the same methods but offered a ground truth.Results: In breast DCE‐MRI, the temporal footprint could be reduced 2.3‐fold retrospectively without introducing noticeable artifacts, improving depiction of rapidly enhancing lesions. Further, experiments with variable‐flip‐angle data showed that reducing view sharing improved accuracy in reconstruction and T1 mapping. In abdominal MRI, 2.3‐fold and 3.6‐fold reductions in temporal footprint allowed reduced motion artifacts.Conclusion: The complementary‐Poisson‐disc k‐space sampling trajectory allowed a retrospective spatiotemporal resolution tradeoff using CS and view sharing, imparting robustness to motion and contrast enhancement. The technique was also validated using a novel approach of fully acquired variable‐flip‐angle acquisition. Magn Reson Med 77:1774–1785, 2017. © 2016 International Society for Magnetic Resonance in Medicine