Wafer-Scale Microtensile Testing of Thin Films
Authors:
- João GasparJGJoão Gaspar
- Marek E. SchmidtMSMarek E. Schmidt
- Jochen HeldJHJochen Held
- Oliver PaulOPOliver Paul
- 18 September 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 18 (5) , 1062-1076
Abstract
This paper reports on the mechanical characterization of thin films using the microtensile technique performed for the first time at the wafer scale. Multiple test structures are processed and sequentially measured on the same silicon substrate, thus eliminating delicate handling of individual samples. The current layout uses 26 test structures evenly distributed over a 4-in wafer, each of them carrying a microtensile specimen that bridges the gap between the fixed and movable parts of the micromachined wafer. A fully automated high-throughput setup makes possible the fast acquisition of data with statistical relevance for the reliable extraction of material properties. The technique was successfully applied to micrometer- and submicrometer-thick films. Two brittle materials, namely, polycrystalline silicon (poly-Si) obtained by low-pressure chemical vapor deposition and silicon nitride (SiNx) produced by plasma-enhanced chemical vapor deposition, and a ductile material, i.e., evaporated aluminum (Al), were characterized. The extraction of the Young's modulus E, tensile strength sigmau, mean tensile strength sigmatildeu, and Weibull modulus m is demonstrated. Young's moduli thus obtained for the poly-Si, SiNx, and Al films were 156.3plusmn 2.6, 112.2plusmn3.5, and 62.5plusmn 2.5 GPa, respectively. The SiNx layers, which have a mean tensile strength sigmatildeu of 2.084-0.177 +0.169 GPa and m=5.9-1.6 +1.8, are the strongest from the fracture point of view when compared to poly-Si with sigmatildeu=1.382-0.026 +0.023 GPa and m=17.3-3.2 +3.5 and Al with sigmatildeu=0.347plusmn0.013 GPa. In each case, the best estimate of the mean and the corresponding 90% confidence interval were evaluated using maximum likelihood estimation and the likelihood ratio method, respectively, on the basis of Gaussian and Weibull statistics.Keywords
This publication has 89 references indexed in Scilit:
- Monotonic and fatigue testing of freestanding submicron thin beams application for MEMSMicrosystem Technologies, 2007
- Temperature-dependent microtensile testing of thin film materials for application to microelectromechanical systemMicrosystem Technologies, 2006
- Electrostatically actuated polymer microresonatorsApplied Physics Letters, 2005
- A methodology and model for the pull-in parameters of electrostatic actuatorsJournal of Microelectromechanical Systems, 2001
- Fatigue in thin films: lifetime and damage formationMaterials Science and Engineering: A, 2001
- Substrate curvature due to thin film mismatch strain in the nonlinear deformation rangeJournal of the Mechanics and Physics of Solids, 2000
- Elastic moduli, strength, and fracture initiation at sharp notches in etched single crystal silicon microstructuresJournal of Applied Physics, 1999
- SU-8: a low-cost negative resist for MEMSJournal of Micromechanics and Microengineering, 1997
- Comparison of stress measurement techniques in surface micromachiningJournal of Micromechanics and Microengineering, 1997
- Variations in Young's modulus and intrinsic stress of LPCVD-polysilicon due to high-temperature annealingJournal of Micromechanics and Microengineering, 1995