Joao Gaspar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joao Gaspar has a total of 196 co-authors. Here are the top co-authors by number of shared publications:
- Virginia Chu
Instituto de Engenharia de Sistemas e Computadores–Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal
25 shared publications - Joao Pedro Conde
Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Lisbon, Portugal; Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
24 shared publications O. Paul
University of Freiburg 2 Department Microsystems Engineering (IMTEK) Germany
20 shared publications- Luis Alexandre Rocha
CMEMS-UM, University of Minho, 4800-058 Guimarães, Portugal
13 shared publications Oliver Paul
Department of Microsystems Engineering (IMTEK), University of Freiburg Georges-Kohler-Allee 4 103, D-79110 Freiburg, Germany
13 shared publications- Oliver Paul
Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
11 shared publications
Latest Publications
- Open Access
Hybrid Multisite Silicon Neural Probe with Integrated Flexible Connector for Interchangeable Packaging
Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes combine rigid silicon and flexible polymer parts into one single device and allow, for example, the precise integration of complex probe geometries, such as multishank designs, with flexible biocompatible cabling. Despite these advantages and benefiting from highly reproducible fabrication methods on both silicon and polymer substrates, they have not been widely available. This paper presents the development, fabrication, characterization, and in vivo electrophysiological assessment of a hybrid multisite multishank silicon probe with a monolithically integrated polyimide flexible interconnect cable. The fabrication process was optimized at wafer level, and several neural probes with 64 gold electrode sites equally distributed along 8 shanks with an integrated 8 µm thick highly flexible polyimide interconnect cable were produced. The monolithic integration of the polyimide cable in the same fabrication process removed the necessity of the postfabrication bonding of the cable to the probe. This is the highest electrode site density and thinnest flexible cable ever reported for a hybrid silicon/polymer probe. Additionally, to avoid the time-consuming bonding of the probe to definitive packaging, the flexible cable was designed to terminate in a connector pad that can mate with commercial zero-insertion force (ZIF) connectors for electronics interfacing. This allows great experimental flexibility because interchangeable packaging can be used according to experimental demands. High-density distributed in vivo electrophysiological recordings were obtained from the hybrid neural probes with low intrinsic noise and high signal-to-noise ratio (SNR).
Open AccessHybrid Multisite Silicon Neural Probe with Integrated Flexible Connector for Interchangeable Packaging
Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes combine rigid silicon and flexible polymer parts into one single device and allow, for example, the precise integration of complex probe geometries, such as multishank designs, with flexible biocompatible cabling. Despite these advantages and benefiting from highly reproducible fabrication methods on both silicon and polymer substrates, they have not been widely available. This paper presents the development, fabrication, characterization, and in vivo electrophysiological assessment of a hybrid multisite multishank silicon probe with a monolithically integrated polyimide flexible interconnect cable. The fabrication process was optimized at wafer level, and several neural probes with 64 gold electrode sites equally distributed along 8 shanks with an integrated 8 µm thick highly flexible polyimide interconnect cable were produced. The monolithic integration of the polyimide cable in the same fabrication process removed the necessity of the postfabrication bonding of the cable to the probe. This is the highest electrode site density and thinnest flexible cable ever reported for a hybrid silicon/polymer probe. Additionally, to avoid the time-consuming bonding of the probe to definitive packaging, the flexible cable was designed to terminate in a connector pad that can mate with commercial zero-insertion force (ZIF) connectors for electronics interfacing. This allows great experimental flexibility because interchangeable packaging can be used according to experimental demands. High-density distributed in vivo electrophysiological recordings were obtained from the hybrid neural probes with low intrinsic noise and high signal-to-noise ratio (SNR).
- Open Access
Hybrid multisite silicon neural probe with integrated flexible connector for interchangeable packaging
Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes, in particular, allow the integration of complex probe geometries, such as multi-shank designs, with flexible biocompatible cabling. Despite these advantages and benefiting from the highly reproducible fabrication methods on both silicon and polymer substrates, they have not been widely available. This paper presents the development, fabrication, characterization, and in vivo electrophysiological assessment of a hybrid multisite multi-shank silicon probe with a monolithically integrated polyimide flexible interconnect cable. The fabrication process was optimized on wafer level and several neural probes with 64 gold electrode sites equally distributed along 8 shanks with an integrated 8 μm-thick highly flexible polyimide interconnect cable were produce. To avoid the time-consuming bonding of the probe to definitive packaging, the flexible cable was designed to terminate in a connector pad that can mate with commercial zero-insertion force (ZIF) connectors for electronics interfacing. This allows great experimental flexibility since interchangeable packaging can be used according to experimental demands. High-density distributed in vivo electrophysiological recordings were obtained from the hybrid neural probes with low intrinsic noise and high signal-to-noise ratio (SNR).
Open AccessHybrid multisite silicon neural probe with integrated flexible connector for interchangeable packaging
Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes, in particular, allow the integration of complex probe geometries, such as multi-shank designs, with flexible biocompatible cabling. Despite these advantages and benefiting from the highly reproducible fabrication methods on both silicon and polymer substrates, they have not been widely available. This paper presents the development, fabrication, characterization, and in vivo electrophysiological assessment of a hybrid multisite multi-shank silicon probe with a monolithically integrated polyimide flexible interconnect cable. The fabrication process was optimized on wafer level and several neural probes with 64 gold electrode sites equally distributed along 8 shanks with an integrated 8 μm-thick highly flexible polyimide interconnect cable were produce. To avoid the time-consuming bonding of the probe to definitive packaging, the flexible cable was designed to terminate in a connector pad that can mate with commercial zero-insertion force (ZIF) connectors for electronics interfacing. This allows great experimental flexibility since interchangeable packaging can be used according to experimental demands. High-density distributed in vivo electrophysiological recordings were obtained from the hybrid neural probes with low intrinsic noise and high signal-to-noise ratio (SNR).
- Open Access
Double-layer flexible neuronal probe with closely spaced electrodes for high-density in-vivo brain recordings
Flexible probes for brain activity recordings are an attractive emerging approach that reduces mechanical mismatch between probe and neuronal tissue, thus minimizing the risk of brain damage or glial scaring. Although promising, flexible probes still present some technical challenges namely: i) how to overcome probe buckling during brain insertion given its intrinsically low mechanical rigidity; ii) how to fabricate closely spaced electrode configurations for high density recordings by standard lithography techniques in the flexible substrate. Here, we present a new flexible probe based solely on standard and low-cost lithography processes, which has closely spaced 10 μm diameter gold electrode sites on a polyimide substrate with inter-site distances of only 5 μm. By using a double-layer design and fabrication approach we were able to accommodate closely spaced electrode sites at two different depths from probe surface while also providing additional stiffening, just sufficient to prevent probe buckling during brain insertion. Detailed probe characterization through metrology of structural and electrical properties and chemical composition analysis, as well as functional assessment through in vivo high-density recordings of neuronal activity in the mouse cortex, confirmed the viability of this new fabrication approach and that this probe can be used for obtaining high quality brain recordings with excellent signal-to-noise ratio (SNR).
Open AccessDouble-layer flexible neuronal probe with closely spaced electrodes for high-density in-vivo brain recordings
Flexible probes for brain activity recordings are an attractive emerging approach that reduces mechanical mismatch between probe and neuronal tissue, thus minimizing the risk of brain damage or glial scaring. Although promising, flexible probes still present some technical challenges namely: i) how to overcome probe buckling during brain insertion given its intrinsically low mechanical rigidity; ii) how to fabricate closely spaced electrode configurations for high density recordings by standard lithography techniques in the flexible substrate. Here, we present a new flexible probe based solely on standard and low-cost lithography processes, which has closely spaced 10 μm diameter gold electrode sites on a polyimide substrate with inter-site distances of only 5 μm. By using a double-layer design and fabrication approach we were able to accommodate closely spaced electrode sites at two different depths from probe surface while also providing additional stiffening, just sufficient to prevent probe buckling during brain insertion. Detailed probe characterization through metrology of structural and electrical properties and chemical composition analysis, as well as functional assessment through in vivo high-density recordings of neuronal activity in the mouse cortex, confirmed the viability of this new fabrication approach and that this probe can be used for obtaining high quality brain recordings with excellent signal-to-noise ratio (SNR).
- 19 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (3) , 387-396
An Alternative Approach to Investigate V-Shaped Electrothermal Microactuators in Vacuum
In this work, we use a simplified version of Young's solution for the steady-state Joule-heating, that uses temperature dependent thermal and electrical conductivities, to find the temperature and displacement behavior of a V-shaped electrothermal microactuator (ETMA) device. In order to test and validate our approach we performed FEM simulations and actually built an ETMA device by microfabrication. The experimental device displacement was measured in vacuum, with a scanning electron microscope. Our numerical results agree quite well with the FEM simulation and experimental results up to a displacement of (0.8 ± 0.2) μm and applied current of 30 mA. Above 35 mA, an abrupt variation of the resistivity is observed followed by surface degradation at 50 mA and device melting at 52 mA. The validity of our approach is discussed of the device geometry and material parameters.
- 19 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (3) , 387-396
An Alternative Approach to Investigate V-Shaped Electrothermal Microactuators in Vacuum
In this work, we use a simplified version of Young's solution for the steady-state Joule-heating, that uses temperature dependent thermal and electrical conductivities, to find the temperature and displacement behavior of a V-shaped electrothermal microactuator (ETMA) device. In order to test and validate our approach we performed FEM simulations and actually built an ETMA device by microfabrication. The experimental device displacement was measured in vacuum, with a scanning electron microscope. Our numerical results agree quite well with the FEM simulation and experimental results up to a displacement of (0.8 ± 0.2) μm and applied current of 30 mA. Above 35 mA, an abrupt variation of the resistivity is observed followed by surface degradation at 50 mA and device melting at 52 mA. The validity of our approach is discussed of the device geometry and material parameters.
- Open Access
- 15 November 2019
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 9 (4) , 49
A Perspective on Microneedle-Based Drug Delivery and Diagnostics in Paediatrics
Microneedles (MNs) have been extensively explored in the literature as a means to deliver drugs in the skin, surpassing the stratum corneum permeability barrier. MNs are potentially easy to produce and may allow the self-administration of drugs without causing pain or bleeding. More recently, MNs have been investigated to collect/assess the interstitial fluid in order to monitor or detect specific biomarkers. The integration of these two concepts in closed-loop devices holds the promise of automated and minimally invasive disease detection/monitoring and therapy. These assure low invasiveness and, importantly, open a window of opportunity for the application of population-specific and personalised therapies.
- 15 November 2019
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 9 (4) , 49
Open AccessA Perspective on Microneedle-Based Drug Delivery and Diagnostics in Paediatrics
Microneedles (MNs) have been extensively explored in the literature as a means to deliver drugs in the skin, surpassing the stratum corneum permeability barrier. MNs are potentially easy to produce and may allow the self-administration of drugs without causing pain or bleeding. More recently, MNs have been investigated to collect/assess the interstitial fluid in order to monitor or detect specific biomarkers. The integration of these two concepts in closed-loop devices holds the promise of automated and minimally invasive disease detection/monitoring and therapy. These assure low invasiveness and, importantly, open a window of opportunity for the application of population-specific and personalised therapies.
- 1 November 2019
- Published by Elsevier in Precision Engineering
- Vol. 60, 320-325
Automated characterisation and analysis of large arrays of nanostructures fabricated at wafer scale
- 1 November 2019
- Published by Elsevier in Precision Engineering
- Vol. 60, 320-325
Automated characterisation and analysis of large arrays of nanostructures fabricated at wafer scale
- Open Access
- 13 September 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (9) , 607
Manipulation of Magnetic Beads with Thin Film Microelectromagnet Traps
Integration of point-of-care assays can be facilitated with the use of actuated magnetic beads (MB) to perform testing in less expensive settings to enable the delivery of cost-effective care. In this paper we present six different designs of planar microelectromagnets traps (MEMT) with four external coils in series and one central coil connected for an opposite direction of manipulation of MB in microfluidic flows. The development of a simulation tool facilitated the rapid and efficient optimization of designs by presenting the influence of system variables on real time concentrations of MB. Real time experiments are in good agreement with the simulations and showed that the design enabled synchronous concentration and dispersion of MB on the same MEMT. The yield of local concentration is seen to be highly dependent on coil design. Additional coil turns between the central and external coils (inter-windings) doubled magnetic concentration and repulsion with no significant electrical resistance increase. The assemblage of a copper microchannel closed loop cooling system to the coils successfully eliminated the thermal drift promoted by joule heating generated by applied current.
- 13 September 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (9) , 607
Open AccessManipulation of Magnetic Beads with Thin Film Microelectromagnet Traps
Integration of point-of-care assays can be facilitated with the use of actuated magnetic beads (MB) to perform testing in less expensive settings to enable the delivery of cost-effective care. In this paper we present six different designs of planar microelectromagnets traps (MEMT) with four external coils in series and one central coil connected for an opposite direction of manipulation of MB in microfluidic flows. The development of a simulation tool facilitated the rapid and efficient optimization of designs by presenting the influence of system variables on real time concentrations of MB. Real time experiments are in good agreement with the simulations and showed that the design enabled synchronous concentration and dispersion of MB on the same MEMT. The yield of local concentration is seen to be highly dependent on coil design. Additional coil turns between the central and external coils (inter-windings) doubled magnetic concentration and repulsion with no significant electrical resistance increase. The assemblage of a copper microchannel closed loop cooling system to the coils successfully eliminated the thermal drift promoted by joule heating generated by applied current.
- 31 January 2019
- Published by Springer Nature
- p. 121-132
Creative Approaches on Interactive Visualization and Characterization at the Nanoscale
- 31 January 2019
- Published by Springer Nature
- p. 121-132
Creative Approaches on Interactive Visualization and Characterization at the Nanoscale
- Open Access
- 30 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 814
SU-8 Based Waveguide for Optrodes
Neural probes can be equipped with light for optogenetics applications. Different approaches are used for delivering light to the tissue: an optical fiber coupled to the probe, a µLED or a waveguide integrated on the probe. Small probe dimensions, adequate optical power for photostimulation and good tissue penetration for in-vivo experiments are critical requirements. Thus, integrating a waveguide is a promising solution. This work shows the design and simulation of a SU-8 based waveguide for integration in a neural probe. The waveguide contains 3 apertures, spaced by 0.5 mm, which will allow the photostimulation of different brain regions simultaneously.
- 30 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 814
Open AccessSU-8 Based Waveguide for Optrodes
Neural probes can be equipped with light for optogenetics applications. Different approaches are used for delivering light to the tissue: an optical fiber coupled to the probe, a µLED or a waveguide integrated on the probe. Small probe dimensions, adequate optical power for photostimulation and good tissue penetration for in-vivo experiments are critical requirements. Thus, integrating a waveguide is a promising solution. This work shows the design and simulation of a SU-8 based waveguide for integration in a neural probe. The waveguide contains 3 apertures, spaced by 0.5 mm, which will allow the photostimulation of different brain regions simultaneously.
- Open Access
- 13 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1030
Resonant Accelerometer based on Double-Ended Tuning Fork and a Force Amplification Mechanism
Resonant accelerometers are an alternative to amplitude modulated devices due to their higher integration capabilities, since they are encapsulated in vacuum and are stable at low pressures. Vacuum is required for some sensors (i.e., gyroscopes) but amplitude modulated accelerometers tend to be unstable under such conditions and therefore cannot be integrated in the same package. Herewith, a device composed by double-ended tuning fork resonators (DETF) and a force amplification mechanism for sensitivity enhancement is presented. Characterization of the fabricated devices was performed, and the design was successfully validated. A sensitivity close to 80 Hz/g was experimentally measured and the DETF characterization for different driving (AC) and bias voltages (DC) is also presented.
- 13 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1030
Open AccessResonant Accelerometer based on Double-Ended Tuning Fork and a Force Amplification Mechanism
Resonant accelerometers are an alternative to amplitude modulated devices due to their higher integration capabilities, since they are encapsulated in vacuum and are stable at low pressures. Vacuum is required for some sensors (i.e., gyroscopes) but amplitude modulated accelerometers tend to be unstable under such conditions and therefore cannot be integrated in the same package. Herewith, a device composed by double-ended tuning fork resonators (DETF) and a force amplification mechanism for sensitivity enhancement is presented. Characterization of the fabricated devices was performed, and the design was successfully validated. A sensitivity close to 80 Hz/g was experimentally measured and the DETF characterization for different driving (AC) and bias voltages (DC) is also presented.