Volume parcellation for improved dynamic shimming
- 8 January 2008
- journal article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 21 (1-2) , 31-40
Abstract
The need for a homogeneous magnetic field in magnetic resonance imaging is well established, especially at high static magnetic field strengths where susceptibility-induced image distortions and signal losses become excessively large. Dynamic shim updating, where the optimal set of shim currents is applied for each slice during a multi-slice acquisition, has been shown to improve magnetic field homogeneity to a greater extent than conventional global shimming. Here, in an initial feasibility study, we show via simulation that improved efficacy of shimming can be achieved by using the novel parcellated dynamic shimming method. The results of these simulations indicate that parcellated dynamic shimming based on just linear shim terms can perform approximately as well as slice-based dynamic shimming with up to third-order shim terms. This work shows that the effective magnetic field inhomogeneity can be further reduced if shimming and image data acquisition are sequentially performed over a series of compact, cuboidal sub-volumes rather than planes. Further work is needed to develop an imaging approach that can be used for the optimal implementation of parcellated dynamic shimming.Keywords
This publication has 40 references indexed in Scilit:
- Novel gradient coils designed using a boundary element methodConcepts in Magnetic Resonance Part B, 2007
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing techniqueMagnetic Resonance in Medicine, 1999
- A region-growing algorithm for InSAR phase unwrappingIEEE Transactions on Geoscience and Remote Sensing, 1999
- Three‐dimensional mapping of the static magnetic field inside the human headMagnetic Resonance in Medicine, 1996
- Minimum energy MRI gradient coils of general geometryMeasurement Science and Technology, 1992
- Fast, noniterative shimming of spatially localized signals. In vivo analysis of the magnetic field along axesJournal of Magnetic Resonance (1969), 1992
- Projection presaturation: A fast and accurate technique for multidimensional spatial localizationJournal of Magnetic Resonance (1969), 1990
- Automatic shimming for localized spectroscopyMedical Physics, 1988
- A new approach to automatic shimmingJournal of Magnetic Resonance (1969), 1988