Correlation of phantom‐based and log file patient‐specific QA with complexity scores for VMAT
Open Access
- 8 November 2014
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (6) , 204-216
Abstract
The motivation for this study was to reduce physics workload relating to patient-specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites — prostate only, prostate and pelvic node (PPN), and head and neck (H&N) — were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also carried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accuracy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%–99.2%), 99.3% (99.1%–99.5%), and 98.4% (97.3%–98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results ( ). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results ( ). Furthermore, all gamma results displayed a significant correlation with MCS ( ), but not with MU/arc. Average MLC position and gantry angle errors were and over all treatment sites and were not found to affect delivery accuracy. However, variability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong correlation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong correlation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process. PACS number: 87.53.Bn, 87.55.Kh, 87.55.Qr
Keywords
This publication has 40 references indexed in Scilit:
- Octavius 4D characterization for flattened and flattening filter free rotational deliveriesMedical Physics, 2013
- Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatmentsMedical Physics, 2012
- Volumetric-Modulated Arc Therapy: Effective and Efficient End-to-End Patient-Specific Quality AssuranceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Implementing RapidArc into clinical routine: A comprehensive program from machine QA to TPS validation and patient QAMedical Physics, 2011
- Evaluation of a new VMAT QA device, or the “X” and “O” array geometriesJournal of Applied Clinical Medical Physics, 2011
- Consistency and reproducibility of the VMAT plan delivery using three independent validation methodsJournal of Applied Clinical Medical Physics, 2010
- Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single ArcsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Patient‐specific quality assurance method for VMAT treatment deliveryMedical Physics, 2009
- Volumetric Modulated Arc Therapy for Delivery of Prostate Radiotherapy: Comparison With Intensity-Modulated Radiotherapy and Three-Dimensional Conformal RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Commissioning and Quality Assurance of RapidArc Radiotherapy Delivery SystemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008