3D isotropic resolution diffusion‐prepared magnitude‐stabilized bSSFP imaging with high geometric fidelity at 1.5 Tesla
Authors:
- 23 April 2020
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 47 (8) , 3511-3519
Abstract
Introduction: MRI has been increasingly used in radiation therapy to facilitate tumor and organ delineation and assess treatment response. Diffusion MRI can provide cellularity information and may enable functional‐based treatment planning and adaptation. However, strong distortion associated with the conventional diffusion‐weighted single‐shot echo‐planar imaging (DW‐ssEPI) sequence is problematic for accurate target delineation. The goal of this work is to propose a 3D diffusion sequence with minimal distortion for radiation therapy applications.Methods: A 3D diffusion‐prepared magnitude‐stabilized balanced steady‐state free precession sequence (DP‐MS‐bSSFP) was developed. A 2D navigator was acquired during the linear catalyzation stage of the bSSFP readout to estimate the phase, which was then used in a plane‐by‐plane low‐rank constrained reconstruction to correct the shot‐to‐shot k‐space inconsistency. A diffusion phantom was scanned to evaluate and compare the geometric reliability and apparent diffusion coefficient (ADC) accuracy with the conventional DW‐ssEPI. Eight landmarks were selected on each slice of the images to calculate the target registration error (TRE), which was used as a surrogate for geometric fidelity. The phantom was scanned under both 0℃ and room temperature. Brain scans were performed on five healthy volunteers. In the first volunteer, protocols of 1, 2, and 4 shots per Kz plane were compared. In vivo geometric fidelity and ADC accuracy were evaluated on the remaining four volunteers using the protocol of four shots per Kz plane. In the geometric fidelity study, 8–10 landmarks were picked on each slice to calculate the TRE. Regions of interest were placed on the white matter, the cerebellum, and the cerebrospinal fluid region to evaluate the ADC agreement between DW‐ssEPI and DP‐MS using the Bland‐Altman plot. All scans were performed at 1.5 mm isotropic resolution to meet the high‐resolution requirement of many radiotherapy applications.Results: The DP‐MS had drastically improved geometric accuracy compared with DW‐ssEPI on the phantom. The mean TRE decreased from 2.09 mm to 0.70 mm. The percentage difference of the ADC values between the two diffusion sequences were less than 5.5% and 7% for the 0℃ and room temperature study, respectively. The DW‐ssEPI had strong distortion and susceptibility‐related artifacts at tissue air boundary, whereas distortion was minimal in DP‐MS images. Overall, the mean/max TRE was over 2 mm/7 mm in the volunteers for DW‐ssEPI, whereas less than 0.8 mm/2 mm for DP‐MS. Good ADC agreement was observed for the white matter, the cerebellum, and the CSF based on the Bland‐Altman plots.Conclusion: A 3D diffusion sequence was developed and validated. It provided high‐resolution diffusion imaging with mean distortion less than 1 mm at 1.5 T, and is a promising imaging technique for treatment planning and adaptive radiotherapy.Keywords
This publication has 41 references indexed in Scilit:
- Predicting and monitoring cancer treatment response with diffusion‐weighted MRIJournal of Magnetic Resonance Imaging, 2010
- Steady‐state diffusion‐weighted imaging: theory, acquisition and analysisNMR in Biomedicine, 2010
- High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE)NeuroImage, 2010
- 3D steady‐state diffusion‐weighted imaging with trajectory using radially batched internal navigator echoes (TURBINE)Magnetic Resonance in Medicine, 2009
- High resolution diffusion‐weighted imaging using readout‐segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisitionMagnetic Resonance in Medicine, 2009
- Advanced pancreatic cancer: the use of the apparent diffusion coefficient to predict response to chemotherapyBritish Journal of Radiology, 2009
- Readout-segmented EPI for rapid high resolution diffusion imaging at 3TEuropean Journal of Radiology, 2008
- Predicting Response of Colorectal Hepatic Metastasis: Value of Pretreatment Apparent Diffusion CoefficientsAmerican Journal of Roentgenology, 2007
- High‐resolution diffusion‐weighted 3D MRI, using diffusion‐weighted driven‐equilibrium (DW‐DE) and multishot segmented 3D‐SSFP without navigator echoesMagnetic Resonance in Medicine, 2003
- Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurementsPhysical Chemistry Chemical Physics, 2000