Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient
- 13 January 2017
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (3) , 759-765
Abstract
Purpose To compare dual-energy computed tomography (DECT) aortography using a 70% reduced iodine dose to single-energy CT (SECT) aortography using a standard iodine dose in the same patient. Methods Twenty-one patients with a prior SECT aortography using standard iodine dose had DECT aortography using 70% reduced iodine dose. Section 120 kVp images were compared to DECT images reconstructed at both 50 and 77 keV. Reviewers measured image noise and attenuation in the aorta at eight locations from proximal to distal and subjectively scored vascular enhancement on a four-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The volume CT dose index (CTDIvol) for each exam was recorded. Results Mean iodine dose was 50 g for SECT and 15 g for DECT (70% reduction). Mean aortic attenuation was similar for section 120 kVp (350 ± 67 HU) and DECT 50 keV (338 ± 57 HU, p = 0.547) but was lower at 77 keV (152 ± 23 HU). Measured image noise was greatest at 50 keV (12 ± 5 HU) and was lowest at 77 keV (7 ± 2 HU, p > 0.001). There was no difference in SNR or CNR between 120 kVp and 50 keV (p > 0.05). Mean subjective vascular enhancement scores for SECT were between good and excellent (3.33–3.69), and for DECT at 50 keV were between moderate and good (2.54–2.93, p < 0.0001). CTDIvol was 13.6 mGy for SECT and 13.1 mGy for DECT (p = 0.637). Conclusion 70% Reduced iodine DECT aortography may result in similar aortic attenuation, CNR, SNR, and lower although acceptable subjective image scores when compared to standard iodine SECT aortography in the same patient.Keywords
Funding Information
- GE Healthcare
This publication has 14 references indexed in Scilit:
- Dual-energy CT Aortography with 50% Reduced Iodine Dose Versus Single-energy CT Aortography with Standard Iodine DoseAcademic Radiology, 2016
- Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imagingThe International Journal of Cardiovascular Imaging, 2015
- Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agentEuropean Journal of Radiology, 2015
- Substantial iodine volume load reduction in CT angiography with dual-energy imaging: insights from a pilot randomized studyThe International Journal of Cardiovascular Imaging, 2014
- Current concepts of contrast-induced nephropathy: A brief reviewJournal of the Chinese Medical Association, 2013
- Indirect Computed Tomography Venography of the Lower Extremities Using Single-Source Dual-Energy Computed Tomography: Advantage of Low-Kiloelectron Volt Monochromatic ImagesJournal of Vascular and Interventional Radiology, 2012
- Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized TrialRadiology, 2012
- Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studiesEuropean Journal of Radiology, 2011
- High incidence of renal failure in patients with aortic aneurysmsNephrology Dialysis Transplantation, 2007
- Aortoiliac Enhancement During Computed Tomography Angiography With Reduced Contrast Material Dose and Saline Solution FlushInvestigative Radiology, 2004