William P. Shuman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William P. Shuman has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Janet M. Busey
Department of Radiology, University of Washington, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
3 shared publicationsKent M. Koprowicz
Department of Radiology, University of Washington, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
2 shared publicationsMario M. Ramos
Department of Radiology, University of Washington, 1959 NE Pacific Street, Box 357115, Seattle, WA, 98195, USA
2 shared publicationsDoug E. Green
University of Washington, Department of Radiology, Box 357115, 1959 NE Pacific Street, USA, Seattle, WA, 98195
1 shared publication- Dushyant Vasudeo Sahani
Department of Radiology, University of Washington, Seattle, USA
1 shared publication - Erik V. Soloff
Department of Radiology, University of Washington, Seattle, WA
1 shared publication
Latest Publications
- Open Access
- 28 July 2023
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 47 (5) , 680-681
How to Take Good Care of Your Radiology Department Chair and Why
- 28 July 2023
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 47 (5) , 680-681
Open AccessHow to Take Good Care of Your Radiology Department Chair and Why
- 24 April 2020
- Published by Springer Nature in Abdominal Radiology
- Vol. 45 (8) , 2370-2377
Feasibility of wide detector three-pass arterial phase liver CT in patients with cirrhosis: timing of hyperenhancing lesion peak conspicuity
Purpose To evaluate feasibility of a wide detector liver CT protocol with three acquisitions in the hepatic arterial phase. Methods Forty-one patients with cirrhosis prospectively underwent a wide detector axial liver CT protocol. Three 16 cm axial liver acquisitions were obtained during a single breath hold at peak aortic enhancement plus 10, 20, and 25 s. Two readers working separately scored overall exam quality, identified hyperenhancing lesions, and subjectively scored and ranked relative lesion conspicuity. Objective lesion enhancement was measured and CNR calculated. Data were analyzed using a generalized linear models and Tukey’s post hoc testing. Results Seventy-one hyperenhancing lesions were identified with average size of 1.8 cm (range 0.4–9.6 cm). The two readers separately identified 60 and 54 lesions on the 10 s arterial acquisition, 70 and 67 on the 20 s, and 52 and 51 on the 25 s. The readers determined all exams had diagnostic image quality. Subjective ranking of lesion conspicuity was greatest at 20 s in 62% of lesions but was greatest at 10 or 25 s in 38%. CNR was highest at 20 s in 58% of lesions but was highest at 10 or 25 s in 42%. Overall, there was no significant difference in mean CNR between the three arterial acquisitions. Conclusion A wide detector axial liver CT protocol with three acquisitions in the hepatic arterial phase is technologically feasible and results in diagnostic image quality. With this protocol, peak subjective and objective hyperenhancing lesion conspicuity may be earlier or later than 20 s in up to 40% of lesions.
- 24 April 2020
- Published by Springer Nature in Abdominal Radiology
- Vol. 45 (8) , 2370-2377
Feasibility of wide detector three-pass arterial phase liver CT in patients with cirrhosis: timing of hyperenhancing lesion peak conspicuity
Purpose To evaluate feasibility of a wide detector liver CT protocol with three acquisitions in the hepatic arterial phase. Methods Forty-one patients with cirrhosis prospectively underwent a wide detector axial liver CT protocol. Three 16 cm axial liver acquisitions were obtained during a single breath hold at peak aortic enhancement plus 10, 20, and 25 s. Two readers working separately scored overall exam quality, identified hyperenhancing lesions, and subjectively scored and ranked relative lesion conspicuity. Objective lesion enhancement was measured and CNR calculated. Data were analyzed using a generalized linear models and Tukey’s post hoc testing. Results Seventy-one hyperenhancing lesions were identified with average size of 1.8 cm (range 0.4–9.6 cm). The two readers separately identified 60 and 54 lesions on the 10 s arterial acquisition, 70 and 67 on the 20 s, and 52 and 51 on the 25 s. The readers determined all exams had diagnostic image quality. Subjective ranking of lesion conspicuity was greatest at 20 s in 62% of lesions but was greatest at 10 or 25 s in 38%. CNR was highest at 20 s in 58% of lesions but was highest at 10 or 25 s in 42%. Overall, there was no significant difference in mean CNR between the three arterial acquisitions. Conclusion A wide detector axial liver CT protocol with three acquisitions in the hepatic arterial phase is technologically feasible and results in diagnostic image quality. With this protocol, peak subjective and objective hyperenhancing lesion conspicuity may be earlier or later than 20 s in up to 40% of lesions.
- 13 January 2017
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (3) , 759-765
Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient
Purpose To compare dual-energy computed tomography (DECT) aortography using a 70% reduced iodine dose to single-energy CT (SECT) aortography using a standard iodine dose in the same patient. Methods Twenty-one patients with a prior SECT aortography using standard iodine dose had DECT aortography using 70% reduced iodine dose. Section 120 kVp images were compared to DECT images reconstructed at both 50 and 77 keV. Reviewers measured image noise and attenuation in the aorta at eight locations from proximal to distal and subjectively scored vascular enhancement on a four-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The volume CT dose index (CTDIvol) for each exam was recorded. Results Mean iodine dose was 50 g for SECT and 15 g for DECT (70% reduction). Mean aortic attenuation was similar for section 120 kVp (350 ± 67 HU) and DECT 50 keV (338 ± 57 HU, p = 0.547) but was lower at 77 keV (152 ± 23 HU). Measured image noise was greatest at 50 keV (12 ± 5 HU) and was lowest at 77 keV (7 ± 2 HU, p > 0.001). There was no difference in SNR or CNR between 120 kVp and 50 keV (p > 0.05). Mean subjective vascular enhancement scores for SECT were between good and excellent (3.33–3.69), and for DECT at 50 keV were between moderate and good (2.54–2.93, p < 0.0001). CTDIvol was 13.6 mGy for SECT and 13.1 mGy for DECT (p = 0.637). Conclusion 70% Reduced iodine DECT aortography may result in similar aortic attenuation, CNR, SNR, and lower although acceptable subjective image scores when compared to standard iodine SECT aortography in the same patient.
- 13 January 2017
- Published by Springer Nature in Abdominal Radiology
- Vol. 42 (3) , 759-765
Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient
Purpose To compare dual-energy computed tomography (DECT) aortography using a 70% reduced iodine dose to single-energy CT (SECT) aortography using a standard iodine dose in the same patient. Methods Twenty-one patients with a prior SECT aortography using standard iodine dose had DECT aortography using 70% reduced iodine dose. Section 120 kVp images were compared to DECT images reconstructed at both 50 and 77 keV. Reviewers measured image noise and attenuation in the aorta at eight locations from proximal to distal and subjectively scored vascular enhancement on a four-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The volume CT dose index (CTDIvol) for each exam was recorded. Results Mean iodine dose was 50 g for SECT and 15 g for DECT (70% reduction). Mean aortic attenuation was similar for section 120 kVp (350 ± 67 HU) and DECT 50 keV (338 ± 57 HU, p = 0.547) but was lower at 77 keV (152 ± 23 HU). Measured image noise was greatest at 50 keV (12 ± 5 HU) and was lowest at 77 keV (7 ± 2 HU, p > 0.001). There was no difference in SNR or CNR between 120 kVp and 50 keV (p > 0.05). Mean subjective vascular enhancement scores for SECT were between good and excellent (3.33–3.69), and for DECT at 50 keV were between moderate and good (2.54–2.93, p < 0.0001). CTDIvol was 13.6 mGy for SECT and 13.1 mGy for DECT (p = 0.637). Conclusion 70% Reduced iodine DECT aortography may result in similar aortic attenuation, CNR, SNR, and lower although acceptable subjective image scores when compared to standard iodine SECT aortography in the same patient.
- 1 November 2016
- Published by Elsevier in Clinical Imaging
- Vol. 40 (6) , 1213-1218
Wide-detector axial CT versus 4 cm detector helical CT for transcatheter aortic valve replacement: iodine dose, radiation, and image quality
- 1 November 2016
- Published by Elsevier in Clinical Imaging
- Vol. 40 (6) , 1213-1218
Wide-detector axial CT versus 4 cm detector helical CT for transcatheter aortic valve replacement: iodine dose, radiation, and image quality
- 1 May 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (5) , 611-618
Dual-energy CT Aortography with 50% Reduced Iodine Dose Versus Single-energy CT Aortography with Standard Iodine Dose
- 1 May 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (5) , 611-618
Dual-energy CT Aortography with 50% Reduced Iodine Dose Versus Single-energy CT Aortography with Standard Iodine Dose