Pitch calibration of standard nanoscale for uncertainty reduction of certified reference materials for SEM image sharpness evaluation and magnification calibration
- 1 December 2022
- journal article
- research article
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 10 (4) , 044010
Abstract
Scanning electron microscopy (SEM) is widely used to observe and analyze nanostructures on surfaces. To obtain accurate and sharp images by SEM, it is necessary to evaluate the sharpness of SEM images and calibrate the magnification simultaneously. The NMIJ-CRM 5207-a is a certified reference material for image sharpness evaluation and magnification calibration. The certified values of NMIJ-CRM 5207-a are the average pitches in the X- and Y- axes. The major source of uncertainty of the NMIJ-CRM 5207-a is the pitch calibration of the commercially available standard nanoscale. To reduce the uncertainty of the pitch calibration value of the standard nanoscale, the pitch calibration was performed using a metrological atomic force microscope and uncertainty was evaluated in this study.Keywords
This publication has 41 references indexed in Scilit:
- 25 nm pitch comparison between a traceable x-ray diffractometer and a metrological atomic force microscopeMeasurement Science and Technology, 2011
- Uptake and intracellular distribution of silver nanoparticles in human mesenchymal stem cellsActa Biomaterialia, 2011
- Evaluation of uncertainty in grating pitch measurement by optical diffraction using Monte Carlo methodsMeasurement Science and Technology, 2010
- Bilateral comparison of 25 nm pitch nanometric lateral scales for metrological scanning probe microscopesMeasurement Science and Technology, 2010
- Nanometric lateral scale development with Si/SiO2multilayer thin-film structures and improvement of uncertainty evaluation using analysis of varianceMeasurement Science and Technology, 2008
- Characterization of Submicron-scale Periodic Grooves by Grazing Incidence Ultra-small-angle X-ray ScatteringJapanese Journal of Applied Physics, 2007
- Application of a GaAs/InGaP superlattice in nanometric lateral scalesMeasurement Science and Technology, 2007
- Imaging laser diffractometer for traceable grating pitch calibrationMeasurement Science and Technology, 2007
- Highly Accurate Grating Reference Fabricated by EB Cell Projection LithographyJapanese Journal of Applied Physics, 2005
- Laser interferometric diffractometry for measurements of diffraction grating spacingApplied Optics, 1996