Ryosuke Kizu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryosuke Kizu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ichiko Misumi
National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
16 shared publications - Akiko Hirai
National Institute of Advanced Industrial Science and Technology (Japan)
13 shared publications Satoshi Gonda
National Institute of Advanced Industrial Science and Technology (AIST), National Metrology Institute of Japan (NMIJ), Tsukuba, JAPAN
9 shared publications- Satoshi Gonda
National Institute of Advanced Industrial Science and Technology (Japan)
7 shared publications Ichiko Misumi
National Institute of Advanced Industrial Science and Technology (AIST), National Metrology Institute of Japan (NMIJ), Tsukuba, JAPAN
5 shared publicationsAkiko Hirai
4 shared publications
Latest Publications
- 31 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105019
Abbe error correction in atomic force microscopy using scanner-angle measurements
In many dimensional measurements performed using atomic force microscopy (AFM) systems, a finite Abbe offset is present between the position wherein the scanner displacement is sensed and the actual probe-tip position. The Abbe error induced by angular deviations during scanning is therefore included in AFM measurements. In this study, the Abbe error was evaluated by measuring the angular error of the scanner and a post-processing correction was performed on the AFM data. The angular error of the AFM system with a 45 mm Abbe offset was measured using a triple-beam laser interferometer at a precision on the order of 0.001″ (arcseconds). For an 8 µm scan, the pitch angle exhibited a peak-to-valley value of 0.057″. To assess the accuracy of the correction, a one-dimensional grating with a nominal pitch of 100 nm was measured. After correcting the Abbe error from the AFM data using the measured angular data, the measured pitch decreased from 100.12 nm to 99.94 nm, with an expanded uncertainty of 0.05 nm. A comparison of this measured value with a reference value of 99.98 nm ± 0.04 nm obtained using another AFM system with a negligible Abbe error yielded a performance statistic of | E n | = 0.62 < 1; this confirmed the validity of the corrected result and indicated that accurate Abbe error correction can be achieved even for AFMs with an Abbe offset, without any hardware modification by measuring the angular error of the scanner.
- 31 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105019
Abbe error correction in atomic force microscopy using scanner-angle measurements
In many dimensional measurements performed using atomic force microscopy (AFM) systems, a finite Abbe offset is present between the position wherein the scanner displacement is sensed and the actual probe-tip position. The Abbe error induced by angular deviations during scanning is therefore included in AFM measurements. In this study, the Abbe error was evaluated by measuring the angular error of the scanner and a post-processing correction was performed on the AFM data. The angular error of the AFM system with a 45 mm Abbe offset was measured using a triple-beam laser interferometer at a precision on the order of 0.001″ (arcseconds). For an 8 µm scan, the pitch angle exhibited a peak-to-valley value of 0.057″. To assess the accuracy of the correction, a one-dimensional grating with a nominal pitch of 100 nm was measured. After correcting the Abbe error from the AFM data using the measured angular data, the measured pitch decreased from 100.12 nm to 99.94 nm, with an expanded uncertainty of 0.05 nm. A comparison of this measured value with a reference value of 99.98 nm ± 0.04 nm obtained using another AFM system with a negligible Abbe error yielded a performance statistic of | E n | = 0.62 < 1; this confirmed the validity of the corrected result and indicated that accurate Abbe error correction can be achieved even for AFMs with an Abbe offset, without any hardware modification by measuring the angular error of the scanner.
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanopatterning, Materials, and Metrology
- Vol. 24 (04) , 1-10
Distribution measurement of line edge roughness using a noise correction based on height–height correlation function
BackgroundLine edge roughness (LER) is a critical performance metric in lithography. Current power-spectral-density-based methods, commonly used to evaluate roughness parameters assuming scale-limited self-affine fractal profiles, provide only an average LER value across multiple patterns.AimWe aim to perform noise-corrected (unbiased) LER measurements on individual patterns, thus enabling detailed characterization of their distribution across multiple patterns.ApproachWe applied our proposed height–height correlation function (HHCF)-based noise-correction technique by acquiring profiles from repeated measurements at identical locations and reducing noise via averaging. The average data were then fitted to a theoretical HHCF expression to separate the unbiased HHCF component from noise, and experimental validation was performed on Si line/space patterns with 50 nm linewidths.ResultsThe noise-reduced profiles exhibited sufficiently low noise to allow the extraction of unbiased HHCF curves and corresponding roughness parameters from each profile. Subsequent analysis of 1000 such profiles successfully characterized the LER distribution.ConclusionUsing the HHCF–based noise correction technique, we determined roughness parameters for each pattern, enabling detailed characterization of LER distributions. The LER distribution offers an efficient approach for evaluating mean LER, which remains a critical performance metric. In future work, applying this distribution could support the identification of outliers with exceptionally large LER values and thereby facilitate yield improvement and process optimization.
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanopatterning, Materials, and Metrology
- Vol. 24 (04) , 1-10
Distribution measurement of line edge roughness using a noise correction based on height–height correlation function
BackgroundLine edge roughness (LER) is a critical performance metric in lithography. Current power-spectral-density-based methods, commonly used to evaluate roughness parameters assuming scale-limited self-affine fractal profiles, provide only an average LER value across multiple patterns.AimWe aim to perform noise-corrected (unbiased) LER measurements on individual patterns, thus enabling detailed characterization of their distribution across multiple patterns.ApproachWe applied our proposed height–height correlation function (HHCF)-based noise-correction technique by acquiring profiles from repeated measurements at identical locations and reducing noise via averaging. The average data were then fitted to a theoretical HHCF expression to separate the unbiased HHCF component from noise, and experimental validation was performed on Si line/space patterns with 50 nm linewidths.ResultsThe noise-reduced profiles exhibited sufficiently low noise to allow the extraction of unbiased HHCF curves and corresponding roughness parameters from each profile. Subsequent analysis of 1000 such profiles successfully characterized the LER distribution.ConclusionUsing the HHCF–based noise correction technique, we determined roughness parameters for each pattern, enabling detailed characterization of LER distributions. The LER distribution offers an efficient approach for evaluating mean LER, which remains a critical performance metric. In future work, applying this distribution could support the identification of outliers with exceptionally large LER values and thereby facilitate yield improvement and process optimization.
- 23 April 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (5) , 055005
Comparing bottom–up and top–down SI traceability approaches in dimensional nanometrology: reference material measurements using transmission electron microscopy and atomic force microscopy
The lattice spacing of Si has recently been established as the mise en pratique (MeP) of the SI definition of the metre. These developments may influence the dimensional nanometrology, particularly when implemented in the measurements of semiconductor devices through transmission electron microscopy (TEM). Unlike the conventional top–down approach to SI traceability, which relies on optical interferometry using calibrated laser frequencies, the bottom–up approach uses the Si lattice spacing within the measurement object itself to achieve accurate scaling. To determine the Si lattice spacing as the MeP, studies have validated its equivalence to the conventional top–down approach, specifically metrological atomic force microscopy (AFM), through comparative experiments, revealing no notable mismatches. However, the destructive nature of TEM sample preparation poses a critical limitation. Previous studies were unable to investigate the effect of the sample preparation process on the Si lattice spacing, leading to concerns regarding potential sources of uncertainty that could compromise the reliability of the bottom–up approach in practical applications. To address this challenge, we fabricated a reference material sample via a nondestructive process. This approach enables the evaluation of the effect of TEM sample preparation on Si lattice spacing, facilitating robust assessment of the reliability of the bottom–up approach. Furthermore, a direct comparison between the bottom–up (TEM) and top–down (metrological AFM) approaches was conducted. The results demonstrated the feasibility of the proposed approach. In particular, when comparing the measurement results for dot–dot sidewall distances obtained by the two approaches, an absolute relative difference of 0.02 % was observed on average, with a maximum of 1.08 % and a minimum of 0.14 %. The comparative measurement technique proposed in this study, which is based on nondestructive TEM sample preparation, is a fundamental evaluation technique. This technique strengthens the reliability of the bottom–up approach and extends the applicability of Si lattice spacing as the MeP of the SI definition of the metre.
- 23 April 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (5) , 055005
Comparing bottom–up and top–down SI traceability approaches in dimensional nanometrology: reference material measurements using transmission electron microscopy and atomic force microscopy
The lattice spacing of Si has recently been established as the mise en pratique (MeP) of the SI definition of the metre. These developments may influence the dimensional nanometrology, particularly when implemented in the measurements of semiconductor devices through transmission electron microscopy (TEM). Unlike the conventional top–down approach to SI traceability, which relies on optical interferometry using calibrated laser frequencies, the bottom–up approach uses the Si lattice spacing within the measurement object itself to achieve accurate scaling. To determine the Si lattice spacing as the MeP, studies have validated its equivalence to the conventional top–down approach, specifically metrological atomic force microscopy (AFM), through comparative experiments, revealing no notable mismatches. However, the destructive nature of TEM sample preparation poses a critical limitation. Previous studies were unable to investigate the effect of the sample preparation process on the Si lattice spacing, leading to concerns regarding potential sources of uncertainty that could compromise the reliability of the bottom–up approach in practical applications. To address this challenge, we fabricated a reference material sample via a nondestructive process. This approach enables the evaluation of the effect of TEM sample preparation on Si lattice spacing, facilitating robust assessment of the reliability of the bottom–up approach. Furthermore, a direct comparison between the bottom–up (TEM) and top–down (metrological AFM) approaches was conducted. The results demonstrated the feasibility of the proposed approach. In particular, when comparing the measurement results for dot–dot sidewall distances obtained by the two approaches, an absolute relative difference of 0.02 % was observed on average, with a maximum of 1.08 % and a minimum of 0.14 %. The comparative measurement technique proposed in this study, which is based on nondestructive TEM sample preparation, is a fundamental evaluation technique. This technique strengthens the reliability of the bottom–up approach and extends the applicability of Si lattice spacing as the MeP of the SI definition of the metre.
- 1 October 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanopatterning, Materials, and Metrology
- Vol. 22 (04) , 044002-7
Evaluation of the change in photoresist sidewall roughness due to electron beam-induced shrinkage using atomic force microscopy
BackgroundScanning electron microscopy (SEM) is commonly employed for line edge roughness (LER) measurements; however, achieving high-precision LER measurement of photoresists is difficult through this approach because electron beam (EB) exposure causes shrinkage of materials. Moreover, the differences in the 3D sidewall shape before and after shrinkage have not been investigated in detail.AimEvaluation of the impact of photoresist shrinkage induced by EB exposure on the sidewall roughness of a pattern.ApproachThe shrinkage was observed by measuring a photoresist pattern before and after EB exposure using atomic force microscopy with a tip-tilting technique (tilting-AFM).ResultsEB exposure smoothed the surface roughness, rounded the top corners, and reduced the pattern height. Roughness parameters evaluated via LER analysis showed that with shrinkage, the standard deviation (σ) and roughness exponent (α) decreased, while the correlation length (ξ) increased.ConclusionsThe results show that SEM-based LER measurements may lead to underestimation of σ and α, and the overestimation of ξ because of the effect of EB-induced shrinkage. Overall, we establish a tilting-AFM technique to evaluate the 3D shape of photoresist patterns without EB damage and with high resolution and low noise.
- 1 October 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanopatterning, Materials, and Metrology
- Vol. 22 (04) , 044002-7
Evaluation of the change in photoresist sidewall roughness due to electron beam-induced shrinkage using atomic force microscopy
BackgroundScanning electron microscopy (SEM) is commonly employed for line edge roughness (LER) measurements; however, achieving high-precision LER measurement of photoresists is difficult through this approach because electron beam (EB) exposure causes shrinkage of materials. Moreover, the differences in the 3D sidewall shape before and after shrinkage have not been investigated in detail.AimEvaluation of the impact of photoresist shrinkage induced by EB exposure on the sidewall roughness of a pattern.ApproachThe shrinkage was observed by measuring a photoresist pattern before and after EB exposure using atomic force microscopy with a tip-tilting technique (tilting-AFM).ResultsEB exposure smoothed the surface roughness, rounded the top corners, and reduced the pattern height. Roughness parameters evaluated via LER analysis showed that with shrinkage, the standard deviation (σ) and roughness exponent (α) decreased, while the correlation length (ξ) increased.ConclusionsThe results show that SEM-based LER measurements may lead to underestimation of σ and α, and the overestimation of ξ because of the effect of EB-induced shrinkage. Overall, we establish a tilting-AFM technique to evaluate the 3D shape of photoresist patterns without EB damage and with high resolution and low noise.
- 3 July 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (10) , 105003
Effect of white noise on roughness measurements of self-affine fractals
This study formulated and clarified the presentation of the noise-related error terms in the power spectral density (PSD) and height–height correlation function (HHCF) through a roughness analysis of self-affine fractals. Assuming the noise as white noise, this study simulated the PSD and HHCF of the noisy roughness profile in a typical situation: line-edge roughness measurements involved in semiconductor lithography technology. It was found that conventional noise-correction techniques can bias the PSD/HHCF from those of the true roughness profiles because they do not account for the residual noise-induced error. The findings obtained from the roughness analysis and simulation techniques are expected to benefit various applications, such as clarifying the quantitative residual error in specific situations, selecting the optimum analysis method (PSD or HHCF), estimating the required number of averaged profiles (measurements) that yields sufficiently small noise errors, and considering strategies for noise reduction.
- 3 July 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (10) , 105003
Effect of white noise on roughness measurements of self-affine fractals
This study formulated and clarified the presentation of the noise-related error terms in the power spectral density (PSD) and height–height correlation function (HHCF) through a roughness analysis of self-affine fractals. Assuming the noise as white noise, this study simulated the PSD and HHCF of the noisy roughness profile in a typical situation: line-edge roughness measurements involved in semiconductor lithography technology. It was found that conventional noise-correction techniques can bias the PSD/HHCF from those of the true roughness profiles because they do not account for the residual noise-induced error. The findings obtained from the roughness analysis and simulation techniques are expected to benefit various applications, such as clarifying the quantitative residual error in specific situations, selecting the optimum analysis method (PSD or HHCF), estimating the required number of averaged profiles (measurements) that yields sufficiently small noise errors, and considering strategies for noise reduction.
- 6 June 2023
- Published by Elsevier in Precision Engineering
- Vol. 83, 152-158
Developmental framework of line edge roughness reference standards for next-generation functional micro-/nanostructures
- 6 June 2023
- Published by Elsevier in Precision Engineering
- Vol. 83, 152-158
Developmental framework of line edge roughness reference standards for next-generation functional micro-/nanostructures
- 9 February 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (6) , 065302
Enhancing the precision of 3D sidewall measurements of photoresist using atomic force microscopy with a tip-tilting technique
A key issue associated with advanced lithography techniques for semiconductor-device manufacturing is the reduction in the sidewall roughness of photoresist line patterns, known as line-edge roughness (LER). We have developed a technique for measuring the sidewall of the resist pattern using atomic force microscopy (AFM) that enables three-dimensional (3D), high-resolution, low-noise, and nondestructive measurements. Conventional LER measurement technology using scanning electron microscopy (SEM) causes shrinkage of the resist pattern due to electron-beam (EB) exposure, whereas our new AFM technique can in principle avoid EB-induced shrinkage. This AFM technology is capable of 3D measurements because it employs a tip-tilting mechanism that enables the sharp AFM tip to scan the vertical sidewalls, which is difficult for a conventional AFM technique. In addition, laser interferometers are equipped for the measurement of the AFM tip displacement, which yields high-resolution, high-accuracy, and low-noise results. This technology overcomes issues such as low resolution, noise, and destructive measurements that afflict conventional SEM measurements. In addition, it enables observations and quantitative analyses of the 3D sidewall roughness. For example, in the present experiment, we observed that grain shapes (several tens of nm in size) were formed randomly on the resist sidewall and that there were almost no footing shapes. By analyzing the sidewall profiles with a height resolution of 1 nm, we obtain the roughness (self-affine fractal) parameters at each height. This AFM-based resist sidewall measurement technique can, thus, provide important insights into resist patterning and related process technologies for next-generation semiconductor-device manufacturing.
- 9 February 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (6) , 065302
Enhancing the precision of 3D sidewall measurements of photoresist using atomic force microscopy with a tip-tilting technique
A key issue associated with advanced lithography techniques for semiconductor-device manufacturing is the reduction in the sidewall roughness of photoresist line patterns, known as line-edge roughness (LER). We have developed a technique for measuring the sidewall of the resist pattern using atomic force microscopy (AFM) that enables three-dimensional (3D), high-resolution, low-noise, and nondestructive measurements. Conventional LER measurement technology using scanning electron microscopy (SEM) causes shrinkage of the resist pattern due to electron-beam (EB) exposure, whereas our new AFM technique can in principle avoid EB-induced shrinkage. This AFM technology is capable of 3D measurements because it employs a tip-tilting mechanism that enables the sharp AFM tip to scan the vertical sidewalls, which is difficult for a conventional AFM technique. In addition, laser interferometers are equipped for the measurement of the AFM tip displacement, which yields high-resolution, high-accuracy, and low-noise results. This technology overcomes issues such as low resolution, noise, and destructive measurements that afflict conventional SEM measurements. In addition, it enables observations and quantitative analyses of the 3D sidewall roughness. For example, in the present experiment, we observed that grain shapes (several tens of nm in size) were formed randomly on the resist sidewall and that there were almost no footing shapes. By analyzing the sidewall profiles with a height resolution of 1 nm, we obtain the roughness (self-affine fractal) parameters at each height. This AFM-based resist sidewall measurement technique can, thus, provide important insights into resist patterning and related process technologies for next-generation semiconductor-device manufacturing.
- 1 December 2022
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 10 (4) , 044010
Pitch calibration of standard nanoscale for uncertainty reduction of certified reference materials for SEM image sharpness evaluation and magnification calibration
Scanning electron microscopy (SEM) is widely used to observe and analyze nanostructures on surfaces. To obtain accurate and sharp images by SEM, it is necessary to evaluate the sharpness of SEM images and calibrate the magnification simultaneously. The NMIJ-CRM 5207-a is a certified reference material for image sharpness evaluation and magnification calibration. The certified values of NMIJ-CRM 5207-a are the average pitches in the X- and Y- axes. The major source of uncertainty of the NMIJ-CRM 5207-a is the pitch calibration of the commercially available standard nanoscale. To reduce the uncertainty of the pitch calibration value of the standard nanoscale, the pitch calibration was performed using a metrological atomic force microscope and uncertainty was evaluated in this study.
- 1 December 2022
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 10 (4) , 044010
Pitch calibration of standard nanoscale for uncertainty reduction of certified reference materials for SEM image sharpness evaluation and magnification calibration
Scanning electron microscopy (SEM) is widely used to observe and analyze nanostructures on surfaces. To obtain accurate and sharp images by SEM, it is necessary to evaluate the sharpness of SEM images and calibrate the magnification simultaneously. The NMIJ-CRM 5207-a is a certified reference material for image sharpness evaluation and magnification calibration. The certified values of NMIJ-CRM 5207-a are the average pitches in the X- and Y- axes. The major source of uncertainty of the NMIJ-CRM 5207-a is the pitch calibration of the commercially available standard nanoscale. To reduce the uncertainty of the pitch calibration value of the standard nanoscale, the pitch calibration was performed using a metrological atomic force microscope and uncertainty was evaluated in this study.
- Open Access
- 23 November 2022
- Published by Springer Nature in Nanomanufacturing and Metrology
- Vol. 5 (4) , 445
Correction: Research Activities of Nanodimensional Standards Using Atomic Force Microscopes, Transmission Electron Microscope, and Scanning Electron Microscope at the National Metrology Institute of Japan
- 23 November 2022
- Published by Springer Nature in Nanomanufacturing and Metrology
- Vol. 5 (4) , 445
Open AccessCorrection: Research Activities of Nanodimensional Standards Using Atomic Force Microscopes, Transmission Electron Microscope, and Scanning Electron Microscope at the National Metrology Institute of Japan
- Open Access
- 13 June 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 15
High-resolution sidewall observation and LER measurement of a photoresist pattern by a metrological tilting-AFM
SPIE Digital Library Proceedings
- 13 June 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 15
Open AccessHigh-resolution sidewall observation and LER measurement of a photoresist pattern by a metrological tilting-AFM
SPIE Digital Library Proceedings