Noninvasive Monitoring of Metabolism and Hemodynamics Using Super-Continuum Infrared Spectroscopy of a Cytochrome C Oxidase (SCISCCO) Instrument
Authors:
- Mohammed N. IslamMohammed N. Islam
- Tianqu ZhaiTZTianqu Zhai
- Alexander DobreADAlexander Dobre
- Cynthia N. MeahCMCynthia N. Meah
- Ioulia KovelmanIKIoulia Kovelman
- Steven BroglioSBSteven Broglio
- Daniel A. BeardDBDaniel A. Beard
- Xiaosu HuXHXiaosu Hu
- Jacob R. JosephJJJacob R. Joseph
- Yamaan S. SaadehYSYamaan S. Saadeh
- Rachel RussoRRRachel Russo
- Hasan B. AlamHAHasan B. Alam
Open Access
- 9 October 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 10122
Abstract
We present a novel, noninvasive, super-continuum infrared spectroscopy of cytochrome c oxidase (SCISCCO) system for simultaneously measuring hemodynamic and metabolic parameters, and we demonstrate its utility by applying it to lab calibration tests, human studies, and swine animal studies. The system optically assays the redox state of cytochrome c oxidase (CCO), as well as traditional markers including oxygenated (HbO) and deoxygenated (HbR) hemoglobin. To demonstrate in vivo feasibility, the measured responses of oxygenation and CCO responses to acute ischemia on the arm and forehead in human participants are compared to data from the literature. The validated SCISCCO system is then applied in human studies to measure cerebral oxygenation and the redox state of CCO in participants during an attention test protocol. We show that the redox state of CCO and hemodynamics measured by the SCISCCO system are consistent with the physiological hypothesis established in prior studies. To enable use of the SCISCCO system in laboratory and hospital settings as well as transportation to remote locations, a cart-based SCISCCO prototype system has also been developed. The cart-based SCISCCO prototype is applied to swine animal models undergoing induction of hemorrhagic shock followed by partial resuscitative endovascular balloon occlusion of the aorta (pREBOA). The pilot study demonstrates the feasibility of using the SCISCCO instrument within the context of existing protocols and validates the instrument’s measurements against the physiological and hemodynamic parameters measured by other conventional devices.Keywords
Funding Information
- Medical Technology Enterprise Consortium (MTEC) (MTEC-17-08-MultiTopic-340B, R01HD092498)
- Exercise and Sport Science Initiative (ESSI) at the University of Michigan (MTEC-17-08-MultiTopic-340B, R01HD092498)
- NIH (MTEC-17-08-MultiTopic-340B, R01HD092498)
This publication has 42 references indexed in Scilit:
- Beneficial effects of histone deacetylase inhibition with severe hemorrhage and ischemia-reperfusion injuryJournal of Surgical Research, 2013
- Systematic investigation of changes in oxidized cerebral cytochrome c oxidase concentration during frontal lobe activation in healthy adultsBiomedical Optics Express, 2012
- Effect of valproic acid on acute lung injury in a rodent model of intestinal ischemia reperfusionResuscitation, 2012
- Effects of tranexamic acid on death, vascular occlusive events, and blood transfusion in trauma patients with significant haemorrhage (CRASH-2): a randomised, placebo-controlled trialThe Lancet, 2010
- Multimodal investigation of fMRI and fNIRS derived breath hold BOLD signals with an expanded balloon modelPhysiological Measurement, 2007
- Near-infrared spectroscopy in the detection of regional tissue oxygenation during hypoxic events in preterm infants undergoing critical carePediatric Critical Care Medicine, 2006
- Lethal Injuries and Time to Death in a Level I Trauma Center 1 1The views expressed in this article are those of the author(s) and do not reflect the official policy or position of the Department of the Navy, Department of Defense, nor the U.S. Government.Journal of the American College of Surgeons, 1998
- Epidemiology of Trauma DeathsThe Journal of Trauma: Injury, Infection, and Critical Care, 1995
- Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopyPhysics in Medicine & Biology, 1995
- Noninvasive, Infrared Monitoring of Cerebral and Myocardial Oxygen Sufficiency and Circulatory ParametersScience, 1977