ADAlexander Dobre

Alexander Dobre

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Dobre has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Noninvasive Monitoring of Metabolism and Hemodynamics Using Super-Continuum Infrared Spectroscopy of a Cytochrome C Oxidase (SCISCCO) Instrument

    by Mohammed N. Islam, Tianqu Zhai, Alexander Dobre, Cynthia N. Meah, Ioulia Kovelman, Steven Broglio, Daniel A. Beard, Xiaosu Hu, Jacob R. Joseph, Yamaan S. Saadeh, et al.

    We present a novel, noninvasive, super-continuum infrared spectroscopy of cytochrome c oxidase (SCISCCO) system for simultaneously measuring hemodynamic and metabolic parameters, and we demonstrate its utility by applying it to lab calibration tests, human studies, and swine animal studies. The system optically assays the redox state of cytochrome c oxidase (CCO), as well as traditional markers including oxygenated (HbO) and deoxygenated (HbR) hemoglobin. To demonstrate in vivo feasibility, the measured responses of oxygenation and CCO responses to acute ischemia on the arm and forehead in human participants are compared to data from the literature. The validated SCISCCO system is then applied in human studies to measure cerebral oxygenation and the redox state of CCO in participants during an attention test protocol. We show that the redox state of CCO and hemodynamics measured by the SCISCCO system are consistent with the physiological hypothesis established in prior studies. To enable use of the SCISCCO system in laboratory and hospital settings as well as transportation to remote locations, a cart-based SCISCCO prototype system has also been developed. The cart-based SCISCCO prototype is applied to swine animal models undergoing induction of hemorrhagic shock followed by partial resuscitative endovascular balloon occlusion of the aorta (pREBOA). The pilot study demonstrates the feasibility of using the SCISCCO instrument within the context of existing protocols and validates the instrument’s measurements against the physiological and hemodynamic parameters measured by other conventional devices.


  • Open Access

    Contactless Vital Sign Monitoring System for In-Vehicle Driver Monitoring Using a Near-Infrared Time-of-Flight Camera

    by Kaiwen Guo, Tianqu Zhai, Manoj H. Purushothama, Alexander Dobre, Shawn Meah, Elton Pashollari, Aabhaas Vaish, Carl DeWilde, Mohammed N. Islam

    We demonstrate a Contactless Vital Sign Monitoring (CVSM) system and road-test the system for in-cabin driver monitoring using a near-infrared indirect Time-of-Flight (ToF) camera. The CVSM measures both heart rate (HR) and respiration rate (RR) by leveraging the simultaneously measured grayscale and depth information from a ToF camera. For a camera-based driver monitoring system (DMS), key challenges from varying background illumination and motion-induced artifacts need to be addressed. In this study, active illumination and depth-based motion compensation are used to mitigate these two challenges. For HR measurements, active illumination allows the system to work under various lighting conditions, while our depth-based motion compensation has the advantage of directly measuring the motion of the driver without making prior assumptions about the motion artifacts. In addition, we can extract RR directly from the chest wall motion, circumventing the challenge of acquiring RR from the near-infrared photoplethysmography (PPG) signal of low signal quality. We investigate the system’s performance in various scenarios, including monitoring both drivers and passengers while driving on highways and local roads. Our results show that our CVSM system is ambient light agnostic, and the success rates of HR measurements on the highway are 82% and 71.9% for the passenger and driver, respectively. At the same time, we show that the system can measure RR on users driving on a highway with a mean deviation of −1.4 breaths per minute (BPM). With reliable HR and RR measurement in the vehicle, the CVSM system could one day be a key enabler to sudden sickness or drowsiness detection in DMS.