A lab in the field: high-frequency analysis of water quality and stable isotopes in stream water and precipitation
Open Access
- 23 March 2017
- journal article
- Published by Copernicus GmbH in Hydrology and Earth System Sciences
- Vol. 21 (3) , 1721-1739
Abstract
High-frequency measurements of solutes and isotopes (18O and 2H) in rainfall and streamflow can shed important light on catchment flow pathways and travel times, but the workload and sample storage artifacts involved in collecting, transporting, and analyzing thousands of bottled samples severely constrain catchment studies in which conventional sampling methods are employed. However, recent developments towards more compact and robust analyzers have now made it possible to measure chemistry and water isotopes in the field at sub-hourly frequencies over extended periods. Here, we present laboratory and field tests of a membrane-vaporization continuous water sampler coupled to a cavity ring-down spectrometer for real-time measurements of δ18O and δ2H combined with a dual-channel ion chromatograph (IC) for the synchronous analysis of major cations and anions. The precision of the isotope analyzer was typically better than 0.03 ‰ for δ18O and 0.17 ‰ for δ2H in 10 min average readings taken at intervals of 30 min. Carryover effects were less than 1.2 % between isotopically contrasting water samples for 30 min sampling intervals, and instrument drift could be corrected through periodic analysis of secondary reference standards. The precision of the ion chromatograph was typically ∼ 0.1–1 ppm or better, with relative standard deviations of ∼ 1 % or better for most major ions in stream water, which is sufficient to detect subtle biogeochemical signals in catchment runoff. We installed the coupled isotope analyzer/IC system in an uninsulated hut next to a stream of a small catchment and analyzed stream water and precipitation samples every 30 min over 28 days. These high-frequency measurements facilitated a detailed comparison of event-water fractions via endmember mixing analysis with both chemical and isotope tracers. For two events with relatively dry antecedent moisture conditions, the event-water fractions were < 21 % based on isotope tracers but were significantly overestimated (40 to 82 %) by the chemical tracers. These observations, coupled with the storm-to-storm patterns in precipitation isotope inputs and the associated stream water isotope response, led to a conceptual hypothesis for runoff generation in the catchment. Under this hypothesis, the pre-event water that is mobilized by precipitation events may, depending on antecedent moisture conditions, be significantly shallower, younger, and less mineralized than the deeper, older water that feeds baseflow and thus defines the pre-event endmember used in hydrograph separation. This proof-of-concept study illustrates the potential advantages of capturing isotopic and hydrochemical behavior at a high frequency over extended periods that span multiple hydrologic events.Keywords
All Related Versions
This publication has 57 references indexed in Scilit:
- Set Up of an Automatic Water Quality Sampling System in Irrigation AgricultureSensors, 2013
- Continuous in situ measurements of stable isotopes in liquid waterWater Resources Research, 2012
- Continuous analysis of δ 18 O and δD values of water by diffusion sampling cavity ring‐down spectrometry: a novel sampling device for unattended field monitoring of precipitation, ground and surface watersRapid Communications in Mass Spectrometry, 2011
- Three decades of water quality measurements from the Upper Severn experimental catchments at Plynlimon, Wales: an openly accessible data resource for research, modelling, environmental management and educationHydrological Processes, 2011
- The application of electrical conductivity as a tracer for hydrograph separation in urban catchmentsHydrological Processes, 2007
- Quantifying the relative contributions of riparian and hillslope zones to catchment runoffWater Resources Research, 2003
- Quantifying uncertainty in tracer‐based hydrograph separationsWater Resources Research, 1998
- Estimation of mean water residence times and runoff generation by180 measurements in a Pre-Alpine catchment (Rietholzbach, Eastern Switzerland)Applied Geochemistry, 1997
- Hydrograph separation and flow analysis by specific electrical conductance of waterJournal of Hydrology, 1993
- Hydrograph separation: A comparison of geochemical and isotopic tracersJournal of Hydrology, 1991