Abstract
High-frequency measurements of solutes and isotopes (18O and 2H) in rainfall and streamflow can shed important light on catchment flow pathways and travel times, but the workload and sample storage artifacts involved in collecting, transporting, and analyzing thousands of bottled samples severely constrain catchment studies where conventional sampling methods are employed. However, recent developments towards more compact and robust analyzers have now made it possible to measure chemistry and water isotopes in the field at sub-hourly frequencies over extended periods. Here we present laboratory and field tests of a membrane-vaporization continuous water sampler coupled to a cavity ring-down spectrometer for real-time measurements of δ18O and δ2H, combined with a dual-channel ion chromatograph (IC) for synchronous analysis of major cations and anions. The precision of the isotope analyzer was typically better than 0.03 ‰ for δ18O and 0.17 ‰ for δ2H, for 10 min average readings taken at intervals of 30 min. Carryover effects were less than 1.2 % between isotopically contrasting water samples for 30 min sampling intervals, and instrument drift could be corrected through periodic analysis of secondary reference standards. We tested the coupled isotope analyzer/IC system under field conditions by analyzing streamwater and precipitation every 30 min over 28 days in a small catchment. These high-frequency measurements facilitated a detailed comparison of event-water fractions via end-member mixing analysis with both chemical and isotope tracers. For two events with relatively dry antecedent moisture conditions, event-water fractions were < 20 % based on isotope tracers, but were significantly overestimated (39 % to 83 %) by the chemical tracers. These observations, coupled with the storm-to-storm patterns in precipitation isotope inputs and the associated streamwater isotope response, led to a conceptual hypothesis for runoff generation in the catchment. Under this hypothesis, the pre-event water that is mobilized by precipitation events may, depending on antecedent moisture conditions, be significantly shallower, younger, and less mineralized than the deeper, older water that feeds base flow and thus defines the "pre-event" end-member used in hydrograph separation. This proof-of-concept study illustrates the potential advantages of capturing isotopic and hydrochemical behavior at high frequency over extended periods that span multiple hydrologic events.
All Related Versions

This publication has 45 references indexed in Scilit: