Can Bioimpedance Analysis Be Used to Estimate Absolute Blood Volume in Hemodialysis Patients?
- 5 March 2025
- journal article
- Published by Wiley in Hemodialysis International
- Vol. 29 (3) , 398-403
Abstract
Introduction: Under physiological conditions, blood volume and extracellular volume are in a ratio of 1–3, even in hemodialysis patients. The question therefore arises: can blood volume be inferred from the bioimpedance analysis data? The aim of the study was to compare the blood volumes calculated from extracellular volume determined by bioimpedance analysis data to the actually measured blood volumes.Methods: Immediately before treatment, extracellular volume and volume overload were evaluated by bioimpedance spectroscopy. The actual blood volume was determined by indicator dilution, using an on‐line infusate bolus and subsequent calculation with the data from the relative blood volume monitor. Alternatively, blood volume was calculated from extracellular volume divided by 3 and compared to the measured blood volume.Findings: Overall, there were no significant differences between measured (5.56 ± 1.47 L) and calculated (5.79 ± 1.30 L) blood volumes. However, intra‐individually, there were very large discrepancies with a range of −1.409 to 1.450 L. Median absolute deviation was 382 mL corresponding to 6.2 mL/kg. The differences between measured and calculated blood volumes correlated significantly (r = −0.98; p < 0.001) with the blood to extracellular volume ratio.Discussion: In almost half of patients, blood volume can be inferred from bioimpedance data with sufficient certainty. But the greater the deviation from the physiological blood to extracellular volume ratio of 1–3, the more the calculated blood volumes differ from the measured values. For this reason, bioimpedance data should not be used uncritically to set the ultrafiltration.Keywords
This publication has 43 references indexed in Scilit:
- Differences in bioimpedance-derived fluid status between two versions of the Body Composition MonitorNutrition, 2023
- Bio-impedance spectroscopy added to a fluid management protocol does not improve preservation of residual kidney function in incident hemodialysis patients in a randomized controlled trialKidney International, 2023
- Fluid volume management in hemodialysis: never give up!Kidney International, 2023
- Meta-Analysis of Randomized Controlled Trials Using Tool-Assisted Target Weight Adjustments in Chronic Dialysis PatientsKidney International Reports, 2019
- Extracellular resistance is sensitive to tissue sodium status; implications for bioimpedance-derived fluid volume parameters in chronic kidney diseaseJournal Of Nephrology, 2019
- Value of bioimpedance analysis estimated “dry weight” in maintenance dialysis patients: a systematic review and meta-analysisInternational Urology and Nephrology, 2017
- Impact of fluid status and inflammation and their interaction on survival: a study in an international hemodialysis patient cohortKidney International, 2017
- RENAL RESEARCH INSTITUTE SYMPOSIUM: Temperature Control by the Blood Temperature MonitorSeminars in Dialysis, 2003
- Nature and rate of vascular refilling during hemodialysis and ultrafiltrationKidney International, 1992
- A blood protein monitor for the continuous measurement of blood volume changes during hemodialysisKidney International, 1990