Joachim Kron
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joachim Kron has a total of 275 co-authors. Here are the top co-authors by number of shared publications:
Til Leimbach
KfH Kidney Center Berlin‐Köpenick Berlin Germany
22 shared publicationsSusanne Kron
KfH Kidney Center Berlin‐Köpenick Berlin Germany
17 shared publications- Daniel Schneditz
Otto Loewi Research Center, Division of Physiology, Medical University of Graz, Neue Stiftingtalstrasse 6/V, 8010 Graz, Austria
9 shared publications - Susanne Kron
Department of Nephrology, Charité Universitätsmedizin Berlin, Berlin, Germany
9 shared publications Sabine Aign
7 shared publicationsStefanie Broszeit
Department of Nephrology DRK Clinics Berlin‐Köpenick Berlin Germany
6 shared publications
Latest Publications
- 23 December 2025
- Published by Wiley in Hemodialysis International
- Vol. 30 (2) , 414-415
Blood Volume Cannot Be Calculated From Extracellular Volume
- 23 December 2025
- Published by Wiley in Hemodialysis International
- Vol. 30 (2) , 414-415
Blood Volume Cannot Be Calculated From Extracellular Volume
- 9 July 2025
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (11) , e174
Mistakes Are There to Learn From When and How to Measure
- 9 July 2025
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (11) , e174
Mistakes Are There to Learn From When and How to Measure
- 19 June 2025
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 48 (9) , 638
Does absolute blood volume influence long-term survival in chronic hemodialysis patients?
- 19 June 2025
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 48 (9) , 638
Does absolute blood volume influence long-term survival in chronic hemodialysis patients?
- 5 March 2025
- Published by Wiley in Hemodialysis International
- Vol. 29 (3) , 398-403
Can Bioimpedance Analysis Be Used to Estimate Absolute Blood Volume in Hemodialysis Patients?
Introduction: Under physiological conditions, blood volume and extracellular volume are in a ratio of 1–3, even in hemodialysis patients. The question therefore arises: can blood volume be inferred from the bioimpedance analysis data? The aim of the study was to compare the blood volumes calculated from extracellular volume determined by bioimpedance analysis data to the actually measured blood volumes.Methods: Immediately before treatment, extracellular volume and volume overload were evaluated by bioimpedance spectroscopy. The actual blood volume was determined by indicator dilution, using an on‐line infusate bolus and subsequent calculation with the data from the relative blood volume monitor. Alternatively, blood volume was calculated from extracellular volume divided by 3 and compared to the measured blood volume.Findings: Overall, there were no significant differences between measured (5.56 ± 1.47 L) and calculated (5.79 ± 1.30 L) blood volumes. However, intra‐individually, there were very large discrepancies with a range of −1.409 to 1.450 L. Median absolute deviation was 382 mL corresponding to 6.2 mL/kg. The differences between measured and calculated blood volumes correlated significantly (r = −0.98; p < 0.001) with the blood to extracellular volume ratio.Discussion: In almost half of patients, blood volume can be inferred from bioimpedance data with sufficient certainty. But the greater the deviation from the physiological blood to extracellular volume ratio of 1–3, the more the calculated blood volumes differ from the measured values. For this reason, bioimpedance data should not be used uncritically to set the ultrafiltration.
- 5 March 2025
- Published by Wiley in Hemodialysis International
- Vol. 29 (3) , 398-403
Can Bioimpedance Analysis Be Used to Estimate Absolute Blood Volume in Hemodialysis Patients?
Introduction: Under physiological conditions, blood volume and extracellular volume are in a ratio of 1–3, even in hemodialysis patients. The question therefore arises: can blood volume be inferred from the bioimpedance analysis data? The aim of the study was to compare the blood volumes calculated from extracellular volume determined by bioimpedance analysis data to the actually measured blood volumes.Methods: Immediately before treatment, extracellular volume and volume overload were evaluated by bioimpedance spectroscopy. The actual blood volume was determined by indicator dilution, using an on‐line infusate bolus and subsequent calculation with the data from the relative blood volume monitor. Alternatively, blood volume was calculated from extracellular volume divided by 3 and compared to the measured blood volume.Findings: Overall, there were no significant differences between measured (5.56 ± 1.47 L) and calculated (5.79 ± 1.30 L) blood volumes. However, intra‐individually, there were very large discrepancies with a range of −1.409 to 1.450 L. Median absolute deviation was 382 mL corresponding to 6.2 mL/kg. The differences between measured and calculated blood volumes correlated significantly (r = −0.98; p < 0.001) with the blood to extracellular volume ratio.Discussion: In almost half of patients, blood volume can be inferred from bioimpedance data with sufficient certainty. But the greater the deviation from the physiological blood to extracellular volume ratio of 1–3, the more the calculated blood volumes differ from the measured values. For this reason, bioimpedance data should not be used uncritically to set the ultrafiltration.
- Open Access
- 7 November 2024
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 47 (12) , 939-942
Absolute blood volume and long-term survival in chronic hemodialysis patients
Current online hemodiafiltration devices can be used to determine the absolute blood volume in clinical practice using the dialysate bolus method. Most of publications on this method have focused on preventing intradialytic complications. The influence of absolute blood volume on long-term prognosis has not been reported yet. A total of 79 participants in a previous study about absolute blood volume were followed for 5 years. Patients with a specific blood volume above ( n = 45) and below 75 ml/kg ( n = 34) respectively were compared with regard to survival using Kaplan–Meier analysis. Patients with a specific blood volume below 75 ml/kg had a significantly higher overall 5-year survival rate than patients above 75 ml/kg (70% vs 39%, p = 0.0233). In patients without cardiac dysfunction, there were no significant differences in 5-year survival between a specific blood volume below or above 75 ml/kg (66% vs 51%). A specific blood volume above 75 ml/kg was associated with an increased mortality in patients with mildly impaired left-ventricular systolic ejection fraction of 40%–59%, whereas in patients with normal blood volume this cardiac impairment did not impact mortality (22% vs 90% 5-year survival, p = 0.0036). This demonstrates the significance of optimum volume control for long-term survival particularly in cases of reduced cardiac function.
- 7 November 2024
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 47 (12) , 939-942
Open AccessAbsolute blood volume and long-term survival in chronic hemodialysis patients
Current online hemodiafiltration devices can be used to determine the absolute blood volume in clinical practice using the dialysate bolus method. Most of publications on this method have focused on preventing intradialytic complications. The influence of absolute blood volume on long-term prognosis has not been reported yet. A total of 79 participants in a previous study about absolute blood volume were followed for 5 years. Patients with a specific blood volume above ( n = 45) and below 75 ml/kg ( n = 34) respectively were compared with regard to survival using Kaplan–Meier analysis. Patients with a specific blood volume below 75 ml/kg had a significantly higher overall 5-year survival rate than patients above 75 ml/kg (70% vs 39%, p = 0.0233). In patients without cardiac dysfunction, there were no significant differences in 5-year survival between a specific blood volume below or above 75 ml/kg (66% vs 51%). A specific blood volume above 75 ml/kg was associated with an increased mortality in patients with mildly impaired left-ventricular systolic ejection fraction of 40%–59%, whereas in patients with normal blood volume this cardiac impairment did not impact mortality (22% vs 90% 5-year survival, p = 0.0036). This demonstrates the significance of optimum volume control for long-term survival particularly in cases of reduced cardiac function.
- 3 August 2024
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 47 (10) , 723-728
Vascular refilling in hemodialysis using feedback-controlled ultrafiltration profile
Background: The rate and the duration of ultrafiltration (UF) are considered the most important factors to affect vascular refilling. The aim of the study was to investigate whether a UF profile could improve the vascular refilling. Methods: Dialysis was delivered by a machine providing feedback control of ultrafiltration rates. Absolute blood volume (BV) was measured by dialysate bolus method. Vascular refilling volume ( Vref) was calculated as UF volume – Δ absolute BV. Results: In 40 patients, refilling fraction ( Vref/UF volume) was 30.5% in the first hour. Thereafter, refilling fraction steeply increased and reached maximum values in the third and fourth hour at about 95%. The cumulative refilling fraction was 68.5 ± 9.4% at the end. In 14 patients, refilling data from the feedback-controlled UF profile were compared to dialysis sessions with constant UF rates. In 12 of 14 patients, refilling fraction was significantly ( p = 0.013) higher in sessions with UF profile (71.6% vs 64.4%). There was a significant negative correlation ( r = -0.606; p = 0.002) between the blood volume to extracellular volume ratio and the refilling fraction. The sum of this ratio and the refilling fraction was 1.01 ± 0.06. Conclusions: Despite significant differences, a feedback-controlled UF profile has no advantage over the previous refilling studies with regard to the refilling fraction because vascular refilling seems to depend mainly on the ratio of BV to ECV. This would explain the different results in studies using BV guided UF feedback programs.
- 3 August 2024
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 47 (10) , 723-728
Vascular refilling in hemodialysis using feedback-controlled ultrafiltration profile
Background: The rate and the duration of ultrafiltration (UF) are considered the most important factors to affect vascular refilling. The aim of the study was to investigate whether a UF profile could improve the vascular refilling. Methods: Dialysis was delivered by a machine providing feedback control of ultrafiltration rates. Absolute blood volume (BV) was measured by dialysate bolus method. Vascular refilling volume ( Vref) was calculated as UF volume – Δ absolute BV. Results: In 40 patients, refilling fraction ( Vref/UF volume) was 30.5% in the first hour. Thereafter, refilling fraction steeply increased and reached maximum values in the third and fourth hour at about 95%. The cumulative refilling fraction was 68.5 ± 9.4% at the end. In 14 patients, refilling data from the feedback-controlled UF profile were compared to dialysis sessions with constant UF rates. In 12 of 14 patients, refilling fraction was significantly ( p = 0.013) higher in sessions with UF profile (71.6% vs 64.4%). There was a significant negative correlation ( r = -0.606; p = 0.002) between the blood volume to extracellular volume ratio and the refilling fraction. The sum of this ratio and the refilling fraction was 1.01 ± 0.06. Conclusions: Despite significant differences, a feedback-controlled UF profile has no advantage over the previous refilling studies with regard to the refilling fraction because vascular refilling seems to depend mainly on the ratio of BV to ECV. This would explain the different results in studies using BV guided UF feedback programs.
- 1 August 2024
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (4) , e54-e57
Estimation of Absolute Blood Volume Using Online Dialysate Dilution: When and How to Measure?
Absolute blood volume can be calculated from the increase in relative blood volume after an infusion of a well-defined volume bolus of ultrapure dialysate into the extracorporeal circulation. Several working groups have applied this method in research and clinical practice. A critical analysis of differing blood volume data between working groups revealed methodologic problems of the measurement procedure and some important technical aspects. This paper presents a statement to standardize the method.
- 1 August 2024
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 71 (4) , e54-e57
Estimation of Absolute Blood Volume Using Online Dialysate Dilution: When and How to Measure?
Absolute blood volume can be calculated from the increase in relative blood volume after an infusion of a well-defined volume bolus of ultrapure dialysate into the extracorporeal circulation. Several working groups have applied this method in research and clinical practice. A critical analysis of differing blood volume data between working groups revealed methodologic problems of the measurement procedure and some important technical aspects. This paper presents a statement to standardize the method.
- 25 September 2023
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 46 (10-11) , 581-584
Vascular refilling depends on the ratio of blood volume to extracellular volume in hemodialysis patients
The ratio of blood volume to extracellular volume is approximately one to three under physiological conditions and also in stable chronic hemodialysis patients. Recently, it was found that this ratio remains unchanged during hemodialysis despite ultrafiltration. This would signify that the higher the ratio, the lower the refilling and vice versa. To test this hypothesis, treatment data of a previous study were re-analyzed. In 79 stable chronic hemodialysis patients, the refilling fraction was 0.749 ± 0.094. There was a significant negative correlation ( r = −0.412; p < 0.001) between the blood volume to extracellular volume ratio and the refilling fraction. The blood volume to extracellular volume relationship seems to be a significant determinant of vascular refilling: the higher the ratio, the lower the refilling, and vice versa.
- 25 September 2023
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 46 (10-11) , 581-584
Vascular refilling depends on the ratio of blood volume to extracellular volume in hemodialysis patients
The ratio of blood volume to extracellular volume is approximately one to three under physiological conditions and also in stable chronic hemodialysis patients. Recently, it was found that this ratio remains unchanged during hemodialysis despite ultrafiltration. This would signify that the higher the ratio, the lower the refilling and vice versa. To test this hypothesis, treatment data of a previous study were re-analyzed. In 79 stable chronic hemodialysis patients, the refilling fraction was 0.749 ± 0.094. There was a significant negative correlation ( r = −0.412; p < 0.001) between the blood volume to extracellular volume ratio and the refilling fraction. The blood volume to extracellular volume relationship seems to be a significant determinant of vascular refilling: the higher the ratio, the lower the refilling, and vice versa.
- 16 June 2022
- Published by Wiley in Hemodialysis International
- Vol. 26 (4) , 540-547
Dynamics of vascular refilling in extended nocturnal hemodialysis
Introduction Long dialysis treatments are generally assumed to mitigate the ultrafiltration (UF) induced volume perturbation and to improve vascular refilling because of reduced UF rates and sufficient time for volume re-equilibration. The time course of vascular refilling was therefore examined during extended nocturnal dialysis. Methods For each hour of dialysis, vascular refilling volume was calculated from the absolute blood volume changes and UF volume removed. Absolute blood volume was estimated by indicator dilution at the beginning of dialysis and then tracked with a relative blood volume monitor. The refilling fraction was defined as the ratio of refilling volume to UF volume. Findings Ten stable chronic hemodialysis (HD) patients were studied during extended (7 h) nocturnal treatment sessions. Specific UF rate was 4.8 +/- 1.8 ml/kg/h. In the 1 h, refilling volume amounted to only 23% of UF volume. Thereafter, refilling fraction steeply increased and reached maximum values in the 2, 3 and 4 h at about mean 90% (91.5%, 88.7%, and 91.1% respectively). From the 5 h on, refilling volume decreased (5 h 81.3%, 6 h 72.5%, 7 h 70.0% of UF volume). Cumulative refilling reached 73.6% of UF volume after 4 h of treatment time. This did not change during the further course of HD. Cumulative refilling volume showed a strong correlation (r = 0.94; p < 0.001) with UF volume. The ratio of blood volume to extracellular volume (R-bex) was 0.306 +/- 0.029 before and slightly but significantly increased to 0.326 +/- 0.030 after UF. Discussion In spite of low-UF rates and extended treatment times, overall refilling fraction reached only 74% and was not different from the refilling fraction observed in regular HD. This value seems to represent a point where UF-induced volume perturbation is adequately compensated by physiologic control mechanisms.
- 16 June 2022
- Published by Wiley in Hemodialysis International
- Vol. 26 (4) , 540-547
Dynamics of vascular refilling in extended nocturnal hemodialysis
Introduction Long dialysis treatments are generally assumed to mitigate the ultrafiltration (UF) induced volume perturbation and to improve vascular refilling because of reduced UF rates and sufficient time for volume re-equilibration. The time course of vascular refilling was therefore examined during extended nocturnal dialysis. Methods For each hour of dialysis, vascular refilling volume was calculated from the absolute blood volume changes and UF volume removed. Absolute blood volume was estimated by indicator dilution at the beginning of dialysis and then tracked with a relative blood volume monitor. The refilling fraction was defined as the ratio of refilling volume to UF volume. Findings Ten stable chronic hemodialysis (HD) patients were studied during extended (7 h) nocturnal treatment sessions. Specific UF rate was 4.8 +/- 1.8 ml/kg/h. In the 1 h, refilling volume amounted to only 23% of UF volume. Thereafter, refilling fraction steeply increased and reached maximum values in the 2, 3 and 4 h at about mean 90% (91.5%, 88.7%, and 91.1% respectively). From the 5 h on, refilling volume decreased (5 h 81.3%, 6 h 72.5%, 7 h 70.0% of UF volume). Cumulative refilling reached 73.6% of UF volume after 4 h of treatment time. This did not change during the further course of HD. Cumulative refilling volume showed a strong correlation (r = 0.94; p < 0.001) with UF volume. The ratio of blood volume to extracellular volume (R-bex) was 0.306 +/- 0.029 before and slightly but significantly increased to 0.326 +/- 0.030 after UF. Discussion In spite of low-UF rates and extended treatment times, overall refilling fraction reached only 74% and was not different from the refilling fraction observed in regular HD. This value seems to represent a point where UF-induced volume perturbation is adequately compensated by physiologic control mechanisms.
- 15 April 2022
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 37 (10) , 2034-2036
The blood to extracellular volume relationship is stable and in the physiologic range in chronic haemodialysis patients
Susanne Kron, Daniel Schneditz, Joachim Kron; The blood to extracellular volume relationship is stable and in the physiologic range in chronic haemodialysis pat
- 15 April 2022
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 37 (10) , 2034-2036
The blood to extracellular volume relationship is stable and in the physiologic range in chronic haemodialysis patients
Susanne Kron, Daniel Schneditz, Joachim Kron; The blood to extracellular volume relationship is stable and in the physiologic range in chronic haemodialysis pat