Cadaveric gait simulation reproduces foot and ankle kinematics from population‐specific inputs
- 6 June 2016
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (9) , 1663-1668
Abstract
Cadaveric gait simulation allows researchers to directly investigate biomechanical consequences of surgeries using invasive measurement techniques. However, it is unclear if foot and ankle kinematics that are population‐specific are reproduced using these devices. Therefore, we assessed foot and ankle kinematics produced in a cadaveric gait simulator during the stance phase of gait in a set of five cadaveric feet. Tibial motions and ground reaction forces previously collected in vivo in a group of healthy adults were applied as inputs parameters. In vitro foot and ankle kinematics were acquired and directly compared to population‐specific in vivo kinematics of the same healthy adults from which input parameters were acquired. Analyses were completed using cross correlation to determine the similarities in kinematic profiles and joint ranges of motion were calculated to determine absolute differences in kinematics. Ankle, subtalar, and talonavicular in vitro joint kinematics were positively correlated to in vivo joint kinematics (rxy = 0.57–0.87). Further, in vivo and in vitro foot and ankle kinematics demonstrated similar amounts of within‐group variability (rxy = 0.50–0.85 and rxy = 0.72–0.76, respectively). Our findings demonstrate that cadaveric gait simulation techniques reproduce population‐specific foot and ankle kinematics, providing a valuable research tool for testing surgical treatments of foot and ankle maladies. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1663–1668, 2016.Keywords
This publication has 39 references indexed in Scilit:
- Extrinsic Muscle Forces Affect Ankle Loading Before and After Total Ankle ArthroplastyClinical Orthopaedics and Related Research, 2015
- An in vitro approach to the evaluation of foot-ankle kinematics: Performance evaluation of a custom-built gait simulatorProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2013
- A Robotic Cadaveric Gait Simulator With Fuzzy Logic Vertical Ground Reaction Force ControlIEEE Transactions on Robotics, 2012
- A Robotic Cadaveric Flatfoot Analysis of Stance PhaseJournal of Biomechanical Engineering, 2011
- Design and Validation of a General Purpose Robotic Testing System for Musculoskeletal ApplicationsJournal of Biomechanical Engineering, 2010
- Subject-specific models of the hindfoot reveal a relationship between morphology and passive mechanical propertiesJournal of Biomechanics, 2008
- In vitro study of foot kinematics using a dynamic walking cadaver modelJournal of Biomechanics, 2007
- In Vitro Simulation of Stance Phase Gait Part I: Model VerificationFoot & Ankle International, 2003
- IN VITRO SIMULATION OF THE STANCE PHASE IN HUMAN GAITJournal of Musculoskeletal Research, 2001
- A dynamic cadaver model of the stance phase of gait: performance characteristics and kinetic validationClinical Biomechanics, 1998