A Robotic Cadaveric Gait Simulator With Fuzzy Logic Vertical Ground Reaction Force Control
- 1 February 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 28 (1) , 246-255
Abstract
Lower limb dynamic cadaveric gait simulators are useful to investigate the biomechanics of the foot and ankle, but many systems have several common limitations, which include simplified tendon forces, nonphysiologic tibial kinematics, greatly reduced velocities, scaled body weight (BW), and, most importantly, trial-and-error vertical ground reaction force (vGRF) control. This paper presents the design, development, and validation of the robotic gait simulator (RGS), which addresses these limitations. A 6-degrees-of-freedom (6-DOF) parallel robot was utilized as part of the RGS to recreate the relative tibia to ground motion. A custom-designed nine-axis proportional-integral-derivative (PID) force-control tendon actuation system provided force to the extrinsic tendons of the cadaveric lower limb. A fuzzy logic vGRF controller was developed, which altered tendon forces in real time and iteratively adjusted the robotic trajectory in order to track a target vGRF. The RGS was able to accurately reproduce 6-DOF tibial kinematics, tendon forces, and vGRF with a cadaveric lower limb. The fuzzy logic vGRF controller was able to track the target in vivo vGRF with an average root-mean-square error of only 5.6% BW during a biomechanically realistic 3/4 BW, 2.7-s stance phase simulation.Keywords
This publication has 25 references indexed in Scilit:
- Arthrodesis of the First Metatarsophalangeal Joint: A Robotic Cadaver Study of the Dorsiflexion AngleJournal of Bone and Joint Surgery, 2010
- Design and Validation of a General Purpose Robotic Testing System for Musculoskeletal ApplicationsJournal of Biomechanical Engineering, 2010
- Assessment of the Effects of Diabetes on Midfoot Joint Pressures Using a Robotic Gait SimulatorFoot & Ankle International, 2009
- An objective evaluation of a segmented foot modelGait & Posture, 2009
- Evidence of isometric function of the flexor hallucis longus muscle in normal gaitJournal of Biomechanics, 2008
- In vitro study of foot kinematics using a dynamic walking cadaver modelJournal of Biomechanics, 2007
- Muscle-tendon interaction and elastic energy usage in human walkingJournal of Applied Physiology, 2005
- In Vivo Forces in the Plantar Fascia During the Stance Phase of GaitJournal of the American Podiatric Medical Association, 2003
- In Vitro Simulation of the Stance Phase in Human GaitJournal of Musculoskeletal Research, 2001
- Electromechanical delay in isometric muscle contractions evoked by voluntary, reflex and electrical stimulationEuropean Journal of Applied Physiology, 1995