Correlation and agreement between the bispectral index vs. state entropy during hypothermic cardio‐pulmonary bypass
- 8 January 2010
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 54 (2) , 169-175
Abstract
The bispectral index (BIS) and spectral entropy enable monitoring the depth of anaesthesia. Mild hypothermia has been shown to affect the ability of electroencephalography monitors to reflect the anaesthetic drug effect. The purpose of this study was to investigate the effect of hypothermia during a cardio-pulmonary bypass on the correlation and agreement between the BIS and entropy variables compared with normothermic conditions. This prospective clinical study included coronary artery bypass grafting patients (n=25) evaluating correlation and agreement (Bland-Altman analysis) between the BIS and both spectral and response entropy during a hypothermic cardio-pulmonary bypass (31-34 degrees C) compared with nomothermic conditions (34-37.5 degrees C). Anaesthesia was maintained with propofol and sufentanil and adjusted clinically, while the anaesthetist was blinded to the monitors. The BIS and entropy values decreased during cooling (P<0.05), but the decrease was more pronounced for entropy variables compared with BIS (P<0.05). The correlation coefficients (bias+/-SD; percentage error) between the BIS vs. spectral state entropy and response entropy were r(2)=0.56 (1+/-11; 42%) and r(2)=0.58 (-2+/-11; 43%) under normothermic conditions, and r(2)=0.17 (10+/-12; 77%) and r(2)=0.18 (9+/-11; 68%) under hypothermic conditions, respectively. Bias was significantly increased under hypothermic conditions (P<0.001 vs. normothermia). Acceptable agreement was observed between the BIS and entropy variables under normothermic but not under hypothermic conditions. The BIS and entropy variables may therefore not be interchangeable during a hypothermic cardio-pulmonary bypass.Keywords
This publication has 30 references indexed in Scilit:
- Intrapatient Reproducibility of the BISxp® MonitorAnesthesiology, 2006
- A Comparison of State and Response Entropy Versus Bispectral Index Values During the Perioperative PeriodAnesthesia & Analgesia, 2006
- A Comparison of Bispectral Index and Entropy, or How to Misinterpret BothAnesthesia & Analgesia, 2005
- Clinical comparison of three different anaesthetic depth monitors during cardiopulmonary bypassAnaesthesia, 2005
- Description of the Entropy™ algorithm as applied in the Datex‐Ohmeda S/5™ Entropy ModuleActa Anaesthesiologica Scandinavica, 2004
- Bispectral index monitoring in patients undergoing cardiac surgery under cardiopulmonary bypassEuropean Journal of Anaesthesiology, 2003
- Bispectral Index-Guided Anesthesia in Patients Undergoing Aortocoronary Bypass Grafting: RetractedAnesthesia & Analgesia, 2003
- Clinical usefulness of the bispectral index for titrating propofol target effect‐site concentrationAnaesthesia, 1998
- Clinical usefulness of the bispectral index for titrating propofol target effect-site concentrationAnaesthesia, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986