BBBerthold Bein

Berthold Bein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Berthold Bein has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Leitlinien des European Resuscitation Council 2021

    by Robert Schiewe, Claudia Bönsch, Jan Wnent, Jan-Thorsten Gräsner, Jens Scholz, Berthold Bein

    Dieser Beitrag basiert auf den 2021 veröffentlichten Leitlinien des ERC und fasst die Inhalte der drei Kapitel Epidemiologie, lebensrettende Systeme und Lehre in der Reanimation zusammen. Im Fokus steht u. a. das optimierte Zusammenspiel aller Beteiligten der sog. Überlebenskette, vor allem durch eine Verbesserung der Laienreanimationsquote und der Reanimationsqualität. Eine effiziente Lehre in der Reanimation ist die Basis für eine bestmögliche praktische Umsetzung mit dem ultimativen Ziel der Verbesserung des Überlebens der Patienten. Publication Date: 01 March 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Mechanical ventilation and mortality among 223 critically ill patients with coronavirus disease 2019: A multicentric study in Germany

    by Kevin Roedl, Dominik Jarczak, Liina Thasler, Martin Bachmann, Frank Schulte, Berthold Bein, Christian Friedrich Weber, Ulrich Schäfer, Carsten Veit, Hans-Peter Hauber, et al.


  • Open Access

    Faculty Opinions recommendation of New clinical guidelines on the spinal stabilisation of adult trauma patients - consensus and evidence based.

    by Berthold Bein, Robert Schiewe

    Traumatic spinal cord injury is a relatively rare injury in Denmark but may result in serious neurological consequences. For decades, prehospital spinal stabilisation with a rigid cervical collar and a hard backboard has been considered to be the most appropriate procedure to prevent secondary spinal cord injuries during patient transportation. However, the procedure has been questioned in recent years, due to the lack of high-quality studies supporting its efficacy. A national interdisciplinary task force was therefore established to provide updated clinical guidelines on prehospital procedures for spinal stabilisation of adult trauma patients in Denmark. The guidelines are based on a systematic review of the literature and grading of the evidence, in addition to a standardised consensus process.This process yielded five main recommendations:A strong recommendation against spinal stabilisation of patients with isolated penetrating trauma; a weak recommendation against the prehospital use of a rigid cervical collar and a hard backboard for ABCDE-stable patients; and a weak recommendation for the use of a vacuum mattress for patient transportation. Finally, our group recommends the use of our clinical algorithm to ensure good clinical practice.

  • Open Access

    Hydroxyethyl Starch (HES 130/0.4) Impairs Intestinal Barrier Integrity and Metabolic Function: Findings from a Mouse Model of the Isolated Perfused Small Intestine

    by Yuk Lung Wong, Ingmar Lautenschläger, Heike Dombrowsky, Karina Zitta, Berthold Bein, Thorsten Krause, Torsten Goldmann, Inez Frerichs, Markus Steinfath, Norbert Weiler, et al.

    The application of hydroxyethyl starch (HES) for volume resuscitation is controversially discussed and clinical studies have suggested adverse effects of HES substitution, leading to increased patient mortality. Although, the intestine is of high clinical relevance and plays a crucial role in sepsis and inflammation, information about the effects of HES on intestinal function and barrier integrity is very scarce. We therefore evaluated the effects of clinically relevant concentrations of HES on intestinal function and barrier integrity employing an isolated perfused model of the mouse small intestine. An isolated perfused model of the mouse small intestine was established and intestines were vascularly perfused with a modified Krebs-Henseleit buffer containing 3% Albumin (N=7) or 3% HES (130/0.4; N=7). Intestinal metabolic function (galactose uptake, lactate-to-pyruvate ratio), edema formation (wet-to-dry weight ratio), morphology (histological and electron microscopical analysis), fluid shifts within the vascular, lymphatic and luminal compartments, as well as endothelial and epithelial barrier permeability (FITC-dextran translocation) were evaluated in both groups. Compared to the Albumin group, HES perfusion did not significantly change the wet-to-dry weight ratio and lactate-to-pyruvate ratio. However, perfusing the small intestine with 3% HES resulted in a significant loss of vascular fluid (p<0.01), an increased fluid accumulation in the intestinal lumen (p<0.001), an enhanced translocation of FITC-dextran from the vascular to the luminal compartment (p<0.001) and a significantly impaired intestinal galactose uptake (p<0.001). Morphologically, these findings were associated with an aggregation of intracellular vacuoles within the intestinal epithelial cells and enlarged intercellular spaces. A vascular perfusion with 3% HES impairs the endothelial and epithelial barrier integrity as well as metabolic function of the small intestine.


  • Correlation and agreement between the bispectral index vs. state entropy during hypothermic cardio‐pulmonary bypass

    by P. Meybohm, M. Gruenewald, J. Höcker, J. Renner, J.‐T. Graesner, C. Ilies, J. Scholz, B. Bein

    The bispectral index (BIS) and spectral entropy enable monitoring the depth of anaesthesia. Mild hypothermia has been shown to affect the ability of electroencephalography monitors to reflect the anaesthetic drug effect. The purpose of this study was to investigate the effect of hypothermia during a cardio-pulmonary bypass on the correlation and agreement between the BIS and entropy variables compared with normothermic conditions. This prospective clinical study included coronary artery bypass grafting patients (n=25) evaluating correlation and agreement (Bland-Altman analysis) between the BIS and both spectral and response entropy during a hypothermic cardio-pulmonary bypass (31-34 degrees C) compared with nomothermic conditions (34-37.5 degrees C). Anaesthesia was maintained with propofol and sufentanil and adjusted clinically, while the anaesthetist was blinded to the monitors. The BIS and entropy values decreased during cooling (P<0.05), but the decrease was more pronounced for entropy variables compared with BIS (P<0.05). The correlation coefficients (bias+/-SD; percentage error) between the BIS vs. spectral state entropy and response entropy were r(2)=0.56 (1+/-11; 42%) and r(2)=0.58 (-2+/-11; 43%) under normothermic conditions, and r(2)=0.17 (10+/-12; 77%) and r(2)=0.18 (9+/-11; 68%) under hypothermic conditions, respectively. Bias was significantly increased under hypothermic conditions (P<0.001 vs. normothermia). Acceptable agreement was observed between the BIS and entropy variables under normothermic but not under hypothermic conditions. The BIS and entropy variables may therefore not be interchangeable during a hypothermic cardio-pulmonary bypass.


  • Open Access

    Interaction of morphine but not fentanyl with cerebral α2-adrenoceptors in α2-adrenoceptor knockout mice

    by Jan Höcker, Ruwen Böhm, Patrick Meybohm, Matthias Gruenewald, Jochen Renner, Henning Ohnesorge, Jens Scholz, Berthold Bein

    Objectives: α2-Adrenergic and μ-opioid receptors belong to the rhodopsin family of G-protein coupled receptors and mediate antinociceptive effects via similar signal transduction pathways. Previous studies have revealed direct functional interactions between both receptor systems including synergistic and additive effects. To evaluate underlying mechanisms, we have studied whether morphine and fentanyl interacted with α2-adrenoceptor-subtypes in mice lacking one individual α2-adrenoceptor-subtype (α2-adrenoceptor knockout).Methods: Opioid interaction with α2-adrenoceptors was investigated by quantitative receptor autoradiography in brain slices of α2A-, α2B- or α2C-adrenoceptor deficient mice. Displacement of the radiolabelled α2-adrenoceptor agonist [125I]paraiodoclonidine from α2-adrenoceptors in different brain regions by increasing concentrations of morphine, fentanyl and naloxone was analysed. The binding affinity of both opioids to α2-adrenoceptor subtypes in different brain regions was quantified.Key findings: Morphine but not fentanyl or naloxone provoked dose-dependent displacement of [125I]paraiodoclonidine from all α2-adrenoceptor subtypes in the brain regions analysed. Binding affinity was highest in cortex, medulla oblongata and pons of α2A-adrenoceptor knockout mice.Conclusions: Our results indicated that morphine interacted with α2-adrenoceptors showing higher affinity for the α2B and α2C than for the α2A subtype. In contrast, fentanyl and naloxone did not show any relevant affinity to α2-adrenoceptors. This effect may have an impact on the pharmacological actions of morphine.


  • A Comparison of Auditory Evoked Potentials Derived From a Monitor Integrated Module Versus Standard Technique

    by Axel Fudickar, Anna Kluzik, Norbert Weiler, Jens Scholz, Peter Hans Tonner, Berthold Bein

    Measurement of brain stem auditory evoked potentials (BAEP) and midlatency auditory evoked potentials (MLAEP) using a new monitor integrated module was compared with an established device. The aim of this study was to evaluate if the new system could replace the more inconvenient established technique. MLAEP and BAEP were obtained from 19 anesthetized male patients using the AEP-Module for Monitor S/5 [GE, Helsinki, Finland (S/5)] and Neuropack 4 mini [Nihon Kohden, Tokyo, Japan (Neuropack)]. Significance of different results was calculated by paired t test. Bias was estimated by Bland-Altman statistics. Latencies of BAEP were significantly shorter and amplitudes of BAEP were significantly higher for Neuropack. Mean latencies of MLAEP (Pa and Nb) were not significantly different (Pa 44.1+/-4.4 ms vs. 41.9+/-5.4 ms/Nb 66.4+/-5.6 ms vs. 62.8+/-6.5 ms), but methods are not interchangeable owing to great variability (Pa -13.16 to 8.94 ms, Nb -19.15 to 11.79 ms). BAEP recorded by S/5 cannot be used for diagnostic interpretation using generally accepted normal values, but can be used for examining changes during the monitoring period. Mean values of Pa and Nb were not significantly different, but values of the S/5 varied above and below the values of Neuropack such that the measurements could not be used for diagnostic interpretation. However, this did not reduce their usefulness for determining adequate hypnosis.