Radio-Frequency Safety Assessment of Stents in Blood Vessels During Magnetic Resonance Imaging
Open Access
- 22 October 2018
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 9, 1439
Abstract
Purpose: The purpose of this study was to investigate the need for high-resolution detailed anatomical modeling to correctly estimate radio-frequency (RF) safety during magnetic resonance imaging (MRI). RF-induced heating near metallic implanted devices depends on the electric field tangential to the device (Etan). Etan and specific absorption rate (SAR) were analyzed in blood vessels of an anatomical model to understand if a standard gel phantom accurately represents the potential heating in tissues due to passive vascular implants such as stents. Methods: A numerical model of an RF birdcage body coil and an anatomically realistic virtual patient with a native spatial resolution of 1 mm3 were used to simulate the in vivo electric field at 64 MHz (1.5 T MRI system). Maximum values of SAR inside the blood vessels were calculated and compared with peaks in a numerical model of the ASTM gel phantom to see if the results from the simplified and homogeneous gel phantom were comparable to the results from the anatomical model. Etan values were also calculated in selected stent trajectories inside blood vessels and compared with the ASTM result. Results: Peak SAR values in blood vessels were up to ten times higher than those found in the ASTM standard gel phantom. Peaks were found in clinically significant anatomical locations, where stents are implanted as per intended use. Furthermore, Etan results showed that volume-averaged SAR values might not be sufficient to assess RF safety. Conclusion: Computational modeling with a high-resolution anatomical model indicated higher values of the incident electric field compared to the standard testing approach. Further investigation will help develop a robust safety testing method which reflects clinically realistic conditions.Keywords
Funding Information
- Oak Ridge Institute for Science and Education (UNITED STATES)
This publication has 20 references indexed in Scilit:
- Detailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance StudyPLOS ONE, 2012
- Tattoo-Induced Skin “Burn” During Magnetic Resonance Imaging in a Professional Football PlayerSports Health: A Multidisciplinary Approach, 2011
- Toward individualized SAR models and in vivo validationMagnetic Resonance in Medicine, 2011
- Coronary StentsJACC, 2010
- The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulationsPhysics in Medicine & Biology, 2009
- The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: A reviewActa Biomaterialia, 2009
- Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer functionJournal of Magnetic Resonance Imaging, 2007
- Comparison of 15 different stents in superficial femoral arteries by high resolution MRI ex vivo and in vivoJournal of Magnetic Resonance Imaging, 2005
- Coronary Arterial Stents: Safety and Artifacts during MR ImagingRadiology, 2000
- The Visible Human ProjectProceedings of the IEEE, 1998