Detection rate of lymphoscintigraphy with technetium-99 m for pediatric chylopericardium
- 5 February 2026
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (6) , 634-640
Abstract
Objective Lymphoscintigraphy has been used to diagnose chylopericardium; however, systematic studies on its detection rate for pediatric patients are lacking. We assessed the detection rate of lymphoscintigraphy with technetium-99 m for chylopericardium in pediatric patients and the factors affecting its diagnostic accuracy. Methods Ten patients diagnosed with chylopericardium based on pericardiocentesis who underwent lymphoscintigraphy were included in this retrospective study. The diagnosis of chylopericardium was established by consensus among pediatric surgeons, cardiologists, and physicians based on the clinical course, including the etiology of pericardial effusion and reaction to treatment, appearance of chylopericardium, and the level of triglyceride in the pericardium. The presence or absence of tracer accumulation in the pericardium was determined on images obtained 45 min and 2 h post-injection. A negative lymphoscintigraphy result was defined as the absence of accumulation on both images. Several factors were compared between positive and negative result groups using Fisher’s exact test and Mann–Whitney U test: age; cardiac surgery; presence of a drainage tube within the pericardium at scintigraphy; pericardial fluid triglyceride level; and occurrence of chylothorax, liver uptake, and dermal backflow. Results Among the 10 patients with chylopericardium, six had a positive lymphoscintigraphy result. The detection rate was 30.0% (3/10) and 60.0% (6/10) at 45 min and 2 h post-injection, respectively. The positive and negative result groups exhibited significant differences in triglyceride level (358.2 ± 166.4 mg/dl [range, 153–659] vs. 107.3 ± 87.5 mg/dl [range, 57–238], respectively; P = 0.019) and evident chylopericardium based on appearance in the pericardial fluid (6/0 vs. 1/3, respectively; P = 0.033). Other factors did not significantly differ between the groups. However, the presence or absence of a drainage tube within the pericardium at the time of lymphoscintigraphy was not associated with the lymphoscintigraphic result. Conclusion Despite the small cohort, the detection rate of lymphoscintigraphy with technetium-99 m for pediatric chylopericardium 2 h post-injection was 60%, and that obtained 45 min post-injection was 30%. Negative lymphoscintigraphy results may be associated with low triglyceride levels in pericardial effusion.Keywords
This publication has 27 references indexed in Scilit:
- Neonatal lymphatic flow disorders: central lymphatic flow disorder and isolated chylothorax, diagnosis and treatment using novel lymphatic imaging and interventions techniqueCurrent Opinion in Pediatrics, 2022
- Comprehensive review of pericardial diseases using different imaging modalitiesThe International Journal of Cardiovascular Imaging, 2020
- Post-Operative Chylothorax in Patients With Congenital Heart DiseaseJACC, 2017
- Imaging Idiopathic Chylopericardium With 99mTc-SC Lymphoscintigraphy and SPECT/CTClinical Nuclear Medicine, 2015
- Spontaneous Chylopericardium: Delineation of the Underlying Anatomic Pathology by CT LymphangiographyThe Annals of Thoracic Surgery, 2009
- Chylopericardium in adults: A literature review over the past decade (1996–2006)The Journal of Thoracic and Cardiovascular Surgery, 2008
- Pedal Tc-99m phytate lymphoscintigraphy in primary chylopericardiumInternational Journal of Cardiology, 2003
- Strategies to treat protein-losing enteropathySeminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual, 2002
- Lymphoscintigraphy of Isolated ChylopericardiumClinical Nuclear Medicine, 1996
- Radioisotope Scintillation Scanning in the Evaluation of Pericardial EffusionJAMA, 1967