Takahiro Hosokawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takahiro Hosokawa has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
Eiji Oguma
Department of Radiology Saitama Children's Medical Center Saitama Japan
66 shared publicationsYutaka Tanami
Department of Radiology Saitama Children's Medical Center Saitama Japan
64 shared publicationsYumiko Sato
Department of Radiology Saitama Children's Medical Center Saitama Japan
62 shared publicationsHiroshi Kawashima
Division of Surgery Saitama Children's Medical Center Saitama Japan
32 shared publications- Eiji Oguma
Department of Radiology, Saitama Children’s Medical Center, Saitama, Japan
22 shared publications - Yumiko Sato
Department of Radiology, Saitama Children’s Medical Center, Saitama, Japan
21 shared publications
Latest Publications
- 6 November 2026
- Published by Wiley in Journal of Clinical Ultrasound
Ultrasound Findings of Clostridium difficile Infection and Its Induced Pseudomembranous Colitis in Children: Review of the Literature With Image Illustration
Clostridium difficile (CD) causes various conditions in pediatric patients, ranging from asymptomatic colonization to severe colitis that can progress to pseudomembranous colitis (PMC). Appropriate antibiotic treatment is important to prevent catastrophic outcomes. This review article describes the ultrasound findings of various patterns of CD infection. Bowel wall thickening, bowel internal ring, bowel external ring, and ascites were more frequently detected in cases with CD infection. Furthermore, PMC cases showed marked thickening of the entire colon, mucus‐entrapped overlying pseudomembranes, and colonic fluid entrapment within the colonic lumen. The extent of these findings may be attributable to the severity of PMC.
- 6 November 2026
- Published by Wiley in Journal of Clinical Ultrasound
Ultrasound Findings of Clostridium difficile Infection and Its Induced Pseudomembranous Colitis in Children: Review of the Literature With Image Illustration
Clostridium difficile (CD) causes various conditions in pediatric patients, ranging from asymptomatic colonization to severe colitis that can progress to pseudomembranous colitis (PMC). Appropriate antibiotic treatment is important to prevent catastrophic outcomes. This review article describes the ultrasound findings of various patterns of CD infection. Bowel wall thickening, bowel internal ring, bowel external ring, and ascites were more frequently detected in cases with CD infection. Furthermore, PMC cases showed marked thickening of the entire colon, mucus‐entrapped overlying pseudomembranes, and colonic fluid entrapment within the colonic lumen. The extent of these findings may be attributable to the severity of PMC.
- 23 October 2026
- Published by Wiley in Journal of Ultrasound in Medicine
Ultrasonographic Diagnosis of Ectopic Ureter Draining into the Vagina or Vestibule
Objectives: To evaluate the ultrasound diagnostic performance in female pediatric patients with ectopic‐ureter insertion into the vagina/vestibule or urethra/bladder neck and to compare patient characteristics. Methods: Of 34 patients (35 vesicoureteral junctions), ultrasonically evaluated ectopic‐ureter presence and location (vagina/vestibule or urethra/bladder neck). Patients were classified into 2 groups based on surgical findings: with vagina/vestibule or urethra/bladder‐neck insertion. Correct/incorrect location of ectopic‐ureter insertion using ultrasound, presence/absence of nonfunctional kidneys, a duplex collecting system, and duplex vagina were compared between both groups using Fisher's exact test. Results: Of 35 vesicoureteral junctions, 5 could not be evaluated at the junction, 30 (85.7%) had a suspected ectopic ureter, and 26 (74.3%) had a correct location diagnosis. Of 14 with vagina/vestibule insertion, 7 (50.0%) had correctly diagnosed locations. Of 21 with urethra/bladder‐neck insertion, 19 (90.5%) were correctly diagnosed using ultrasound. Of the 13 of 15 patients with nonfunctional kidneys/duplex urinary system, 9 of 1 had findings involving the vagina/vestibule, and 4 of 14 had findings involving the urethra/bladder neck. Statistically significant differences were observed in correct/incorrect ultrasound diagnosis for the location of ectopic‐ureter insertions (vagina/vestibule, 7/7; urethra/bladder‐neck insertions, 19/2; p = .015), nonfunctional/functional kidneys (vagina/vestibule, 9/5; urethra/bladder‐neck insertions, 4/17; p = .012), and presence/absence of duplex collecting system on the ipsilateral side of the ectopic ureter (vagina/vestibule 1/13; urethra/bladder‐neck insertions, 14/7; p < .001). There were no significant differences in presence/absence of duplex vagina ( p = .090). Conclusions: Ultrasound was useful in detecting ectopic‐ureter presence. However, the diagnostic performance for determining the location of vagina/vestibule insertions was approximately 50%. Sonographers should carefully evaluate the vesicoureteral‐insertion location, particularly in cases with nonfunctional kidneys.
- 23 October 2026
- Published by Wiley in Journal of Ultrasound in Medicine
Ultrasonographic Diagnosis of Ectopic Ureter Draining into the Vagina or Vestibule
Objectives: To evaluate the ultrasound diagnostic performance in female pediatric patients with ectopic‐ureter insertion into the vagina/vestibule or urethra/bladder neck and to compare patient characteristics. Methods: Of 34 patients (35 vesicoureteral junctions), ultrasonically evaluated ectopic‐ureter presence and location (vagina/vestibule or urethra/bladder neck). Patients were classified into 2 groups based on surgical findings: with vagina/vestibule or urethra/bladder‐neck insertion. Correct/incorrect location of ectopic‐ureter insertion using ultrasound, presence/absence of nonfunctional kidneys, a duplex collecting system, and duplex vagina were compared between both groups using Fisher's exact test. Results: Of 35 vesicoureteral junctions, 5 could not be evaluated at the junction, 30 (85.7%) had a suspected ectopic ureter, and 26 (74.3%) had a correct location diagnosis. Of 14 with vagina/vestibule insertion, 7 (50.0%) had correctly diagnosed locations. Of 21 with urethra/bladder‐neck insertion, 19 (90.5%) were correctly diagnosed using ultrasound. Of the 13 of 15 patients with nonfunctional kidneys/duplex urinary system, 9 of 1 had findings involving the vagina/vestibule, and 4 of 14 had findings involving the urethra/bladder neck. Statistically significant differences were observed in correct/incorrect ultrasound diagnosis for the location of ectopic‐ureter insertions (vagina/vestibule, 7/7; urethra/bladder‐neck insertions, 19/2; p = .015), nonfunctional/functional kidneys (vagina/vestibule, 9/5; urethra/bladder‐neck insertions, 4/17; p = .012), and presence/absence of duplex collecting system on the ipsilateral side of the ectopic ureter (vagina/vestibule 1/13; urethra/bladder‐neck insertions, 14/7; p < .001). There were no significant differences in presence/absence of duplex vagina ( p = .090). Conclusions: Ultrasound was useful in detecting ectopic‐ureter presence. However, the diagnostic performance for determining the location of vagina/vestibule insertions was approximately 50%. Sonographers should carefully evaluate the vesicoureteral‐insertion location, particularly in cases with nonfunctional kidneys.
- 2 October 2026
- Published by Springer Nature in Journal of Ultrasound
- Vol. 29 (4) , 901-908
Diagnostic performance of ultrasound for gastric volvulus in pediatric patients
- 2 October 2026
- Published by Springer Nature in Journal of Ultrasound
- Vol. 29 (4) , 901-908
Diagnostic performance of ultrasound for gastric volvulus in pediatric patients
- Open Access
- 20 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2)
Perianal Sonographic Approach to Fistula-in-Ano and Perianal Abscesses: A Pictorial Review
Fistula-in-ano and perianal abscesses are common conditions in pediatric patients. Recently, the perianal ultrasound approach has been reported as a useful method for evaluating anal and perianal lesions. However, this technique remains unfamiliar to many sonographers. In this pictorial review, we aimed to describe the basic sonographic approach for assessing fistula-in-ano and perianal abscesses. A sagittal view of the anal canal is obtained by placing the probe on the proctodeum parallel to the intergluteal cleft, providing a longitudinal image of the anus and rectum. The probe is then gently swung from right to left to identify anatomical structures and detect fistula-in-ano or perianal abscesses. When necessary, the probe is rotated perpendicular to the gluteal cleft to obtain additional transverses, offering further diagnostic information. An abscess appears as a hypoechoic (low-echoic) mass surrounded by echogenic subcutaneous tissue and a hypervascular rim due to inflammation. The presence of a fluid-filled, low-echoic mass indicates pus accumulation, prompting surgical incision. The fistula-in-ano typically extends from a rectal crypt to the dermis, and abscess formation may occur along this tract. Perianal ultrasonography is a valuable, noninvasive tool for evaluating perianal lesions, and sonographers should become familiar with this approach. Throughout the procedure, patient comfort and pain management are essential, and further diagnostic imaging or intervention may be warranted when necessary.
- 20 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2)
Open AccessPerianal Sonographic Approach to Fistula-in-Ano and Perianal Abscesses: A Pictorial Review
Fistula-in-ano and perianal abscesses are common conditions in pediatric patients. Recently, the perianal ultrasound approach has been reported as a useful method for evaluating anal and perianal lesions. However, this technique remains unfamiliar to many sonographers. In this pictorial review, we aimed to describe the basic sonographic approach for assessing fistula-in-ano and perianal abscesses. A sagittal view of the anal canal is obtained by placing the probe on the proctodeum parallel to the intergluteal cleft, providing a longitudinal image of the anus and rectum. The probe is then gently swung from right to left to identify anatomical structures and detect fistula-in-ano or perianal abscesses. When necessary, the probe is rotated perpendicular to the gluteal cleft to obtain additional transverses, offering further diagnostic information. An abscess appears as a hypoechoic (low-echoic) mass surrounded by echogenic subcutaneous tissue and a hypervascular rim due to inflammation. The presence of a fluid-filled, low-echoic mass indicates pus accumulation, prompting surgical incision. The fistula-in-ano typically extends from a rectal crypt to the dermis, and abscess formation may occur along this tract. Perianal ultrasonography is a valuable, noninvasive tool for evaluating perianal lesions, and sonographers should become familiar with this approach. Throughout the procedure, patient comfort and pain management are essential, and further diagnostic imaging or intervention may be warranted when necessary.
- 5 February 2026
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (6) , 634-640
Detection rate of lymphoscintigraphy with technetium-99 m for pediatric chylopericardium
Objective Lymphoscintigraphy has been used to diagnose chylopericardium; however, systematic studies on its detection rate for pediatric patients are lacking. We assessed the detection rate of lymphoscintigraphy with technetium-99 m for chylopericardium in pediatric patients and the factors affecting its diagnostic accuracy. Methods Ten patients diagnosed with chylopericardium based on pericardiocentesis who underwent lymphoscintigraphy were included in this retrospective study. The diagnosis of chylopericardium was established by consensus among pediatric surgeons, cardiologists, and physicians based on the clinical course, including the etiology of pericardial effusion and reaction to treatment, appearance of chylopericardium, and the level of triglyceride in the pericardium. The presence or absence of tracer accumulation in the pericardium was determined on images obtained 45 min and 2 h post-injection. A negative lymphoscintigraphy result was defined as the absence of accumulation on both images. Several factors were compared between positive and negative result groups using Fisher’s exact test and Mann–Whitney U test: age; cardiac surgery; presence of a drainage tube within the pericardium at scintigraphy; pericardial fluid triglyceride level; and occurrence of chylothorax, liver uptake, and dermal backflow. Results Among the 10 patients with chylopericardium, six had a positive lymphoscintigraphy result. The detection rate was 30.0% (3/10) and 60.0% (6/10) at 45 min and 2 h post-injection, respectively. The positive and negative result groups exhibited significant differences in triglyceride level (358.2 ± 166.4 mg/dl [range, 153–659] vs. 107.3 ± 87.5 mg/dl [range, 57–238], respectively; P = 0.019) and evident chylopericardium based on appearance in the pericardial fluid (6/0 vs. 1/3, respectively; P = 0.033). Other factors did not significantly differ between the groups. However, the presence or absence of a drainage tube within the pericardium at the time of lymphoscintigraphy was not associated with the lymphoscintigraphic result. Conclusion Despite the small cohort, the detection rate of lymphoscintigraphy with technetium-99 m for pediatric chylopericardium 2 h post-injection was 60%, and that obtained 45 min post-injection was 30%. Negative lymphoscintigraphy results may be associated with low triglyceride levels in pericardial effusion.
- 5 February 2026
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (6) , 634-640
Detection rate of lymphoscintigraphy with technetium-99 m for pediatric chylopericardium
Objective Lymphoscintigraphy has been used to diagnose chylopericardium; however, systematic studies on its detection rate for pediatric patients are lacking. We assessed the detection rate of lymphoscintigraphy with technetium-99 m for chylopericardium in pediatric patients and the factors affecting its diagnostic accuracy. Methods Ten patients diagnosed with chylopericardium based on pericardiocentesis who underwent lymphoscintigraphy were included in this retrospective study. The diagnosis of chylopericardium was established by consensus among pediatric surgeons, cardiologists, and physicians based on the clinical course, including the etiology of pericardial effusion and reaction to treatment, appearance of chylopericardium, and the level of triglyceride in the pericardium. The presence or absence of tracer accumulation in the pericardium was determined on images obtained 45 min and 2 h post-injection. A negative lymphoscintigraphy result was defined as the absence of accumulation on both images. Several factors were compared between positive and negative result groups using Fisher’s exact test and Mann–Whitney U test: age; cardiac surgery; presence of a drainage tube within the pericardium at scintigraphy; pericardial fluid triglyceride level; and occurrence of chylothorax, liver uptake, and dermal backflow. Results Among the 10 patients with chylopericardium, six had a positive lymphoscintigraphy result. The detection rate was 30.0% (3/10) and 60.0% (6/10) at 45 min and 2 h post-injection, respectively. The positive and negative result groups exhibited significant differences in triglyceride level (358.2 ± 166.4 mg/dl [range, 153–659] vs. 107.3 ± 87.5 mg/dl [range, 57–238], respectively; P = 0.019) and evident chylopericardium based on appearance in the pericardial fluid (6/0 vs. 1/3, respectively; P = 0.033). Other factors did not significantly differ between the groups. However, the presence or absence of a drainage tube within the pericardium at the time of lymphoscintigraphy was not associated with the lymphoscintigraphic result. Conclusion Despite the small cohort, the detection rate of lymphoscintigraphy with technetium-99 m for pediatric chylopericardium 2 h post-injection was 60%, and that obtained 45 min post-injection was 30%. Negative lymphoscintigraphy results may be associated with low triglyceride levels in pericardial effusion.
- 10 January 2026
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (5) , 1133-1141
Diagnostic Performance of Ultrasound for Preduodenal Portal Vein Detection in Pediatric Patients: Our Institution's Experience and Review of Previous 130 Case Reports
Purposes: To evaluate the diagnostic performance of ultrasonography in identifying the preduodenal portal vein and examine the factors influencing its diagnostic performance. Furthermore, we reviewed previously published case reports and series on this anomaly. Methods: We included 17 patients diagnosed with a preduodenal portal vein, confirmed by contrast‐enhanced computed tomography and/or surgical findings. Patients were categorized into the following two groups: those in whom the anomaly was detected and those in whom it was not detected via initial ultrasonography. The presence or absence of intestinal malrotation, polysplenia/asplenia, and symptoms were compared using Fisher's exact tests. Results: Of the 17 pediatric patients with a preduodenal portal vein, 10 were correctly diagnosed on initial ultrasonography, yielding a sensitivity of 58.8%. A significant difference was observed only in the presence of symptoms (detection group vs. nondetection group: 7/3 vs. 1/6, p = 0.049). No significant difference was found in the presence or absence of intestinal malrotation (6/4 vs. 5/2, p > 0.999) or splenic anomalies (polysplenia/asplenia: 4/5 vs. 5/2, p = 0.358; one patient had no splenic anomaly). Conclusion: The diagnostic performance of ultrasonography for the duodenal portal vein was more than 50%; however, this anomaly was more likely to be overlooked in asymptomatic patients than in symptomatic patients.
- 10 January 2026
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (5) , 1133-1141
Diagnostic Performance of Ultrasound for Preduodenal Portal Vein Detection in Pediatric Patients: Our Institution's Experience and Review of Previous 130 Case Reports
Purposes: To evaluate the diagnostic performance of ultrasonography in identifying the preduodenal portal vein and examine the factors influencing its diagnostic performance. Furthermore, we reviewed previously published case reports and series on this anomaly. Methods: We included 17 patients diagnosed with a preduodenal portal vein, confirmed by contrast‐enhanced computed tomography and/or surgical findings. Patients were categorized into the following two groups: those in whom the anomaly was detected and those in whom it was not detected via initial ultrasonography. The presence or absence of intestinal malrotation, polysplenia/asplenia, and symptoms were compared using Fisher's exact tests. Results: Of the 17 pediatric patients with a preduodenal portal vein, 10 were correctly diagnosed on initial ultrasonography, yielding a sensitivity of 58.8%. A significant difference was observed only in the presence of symptoms (detection group vs. nondetection group: 7/3 vs. 1/6, p = 0.049). No significant difference was found in the presence or absence of intestinal malrotation (6/4 vs. 5/2, p > 0.999) or splenic anomalies (polysplenia/asplenia: 4/5 vs. 5/2, p = 0.358; one patient had no splenic anomaly). Conclusion: The diagnostic performance of ultrasonography for the duodenal portal vein was more than 50%; however, this anomaly was more likely to be overlooked in asymptomatic patients than in symptomatic patients.
- Open Access
- 1 January 2026
- Published by Elsevier in Journal of Pediatric Surgery Open
- Vol. 13
Incidence of intestinal volvulus in pediatric patients with intestinal malrotation: A single institution's experience
- 1 January 2026
- Published by Elsevier in Journal of Pediatric Surgery Open
- Vol. 13
Open AccessIncidence of intestinal volvulus in pediatric patients with intestinal malrotation: A single institution's experience
- Open Access
- 10 November 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (1) , 99
Reply to the letter to the editor from Memuna Jehan zeb and colleagues
- 10 November 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (1) , 99
Open AccessReply to the letter to the editor from Memuna Jehan zeb and colleagues
- 22 September 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (2) , 136-145
Association between technetium-99 m albumin scintigraphy-based severity of protein-losing enteropathy and patient characteristics and laboratory data
Objective This study aimed to demonstrate the differences in Technetium-99 m albumin scintigraphy findings for patients with protein-losing enteropathy (PLE) associated with their characteristics and laboratory data. Methods Eighteen patients with PLE were grouped into two based on two mechanisms: direct mucosal damage and failed lymph drainage. Scintigraphy images were divided based on the timing of acquisition: images obtained at 1, 2, 4, 6, and 24 h after starting the examination. The intensity of tracer uptake was graded as follows: 3 (marked uptake equal to or greater than the liver level), 2 (moderate uptake less than liver and greater than kidney levels), 1 (mild uptake less than kidney level), and 0 (negative). The grades at each timepoint for the two groups were compared using the Mann–Whitney U test. The associations between the grades and fecal alpha-1-antitrypsin and serum total protein concentrations were evaluated using Pearson correlation coefficients. Results Of 18 patients, 7 had PLE due to failed lymph drainage. The direct mucosal damage and failed lymph drainage groups had significantly different fecal alpha-1-antitrypsin concentrations [43.5 ± 29.6 (range 11–115) vs. 208.7 ± 66.0 (range 124–311), respectively; P < 0.001] and scintigraphy-based severity at 24 h [1.2 ± 0.8 (range 1–3) vs. 2.8 ± 0.4 (range 2–3), respectively; P = 0.007]. The fecal alpha-1-antitrypsin concentration was positively correlated with the scintigraphy-based severity at 6 h (r = 0.499, P = 0.049) and 24 h (r = 0.747, P = 0.002). However, the serum protein concentration was negatively correlated with the scintigraphy-based severity at 6 h (r = − 0.587, P = 0.017). Conclusions The scintigraphy-based severity at 6 and 24 h and the fecal alpha-1-antitrypsin concentrations were higher for patients with PLE due to failed lymph drainage mechanisms than for those with PLE due to direct mucosal damage. Scintigraphy can help localize the leakage point and determine disease severity to guide PLE management.
- 22 September 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (2) , 136-145
Association between technetium-99 m albumin scintigraphy-based severity of protein-losing enteropathy and patient characteristics and laboratory data
Objective This study aimed to demonstrate the differences in Technetium-99 m albumin scintigraphy findings for patients with protein-losing enteropathy (PLE) associated with their characteristics and laboratory data. Methods Eighteen patients with PLE were grouped into two based on two mechanisms: direct mucosal damage and failed lymph drainage. Scintigraphy images were divided based on the timing of acquisition: images obtained at 1, 2, 4, 6, and 24 h after starting the examination. The intensity of tracer uptake was graded as follows: 3 (marked uptake equal to or greater than the liver level), 2 (moderate uptake less than liver and greater than kidney levels), 1 (mild uptake less than kidney level), and 0 (negative). The grades at each timepoint for the two groups were compared using the Mann–Whitney U test. The associations between the grades and fecal alpha-1-antitrypsin and serum total protein concentrations were evaluated using Pearson correlation coefficients. Results Of 18 patients, 7 had PLE due to failed lymph drainage. The direct mucosal damage and failed lymph drainage groups had significantly different fecal alpha-1-antitrypsin concentrations [43.5 ± 29.6 (range 11–115) vs. 208.7 ± 66.0 (range 124–311), respectively; P < 0.001] and scintigraphy-based severity at 24 h [1.2 ± 0.8 (range 1–3) vs. 2.8 ± 0.4 (range 2–3), respectively; P = 0.007]. The fecal alpha-1-antitrypsin concentration was positively correlated with the scintigraphy-based severity at 6 h (r = 0.499, P = 0.049) and 24 h (r = 0.747, P = 0.002). However, the serum protein concentration was negatively correlated with the scintigraphy-based severity at 6 h (r = − 0.587, P = 0.017). Conclusions The scintigraphy-based severity at 6 and 24 h and the fecal alpha-1-antitrypsin concentrations were higher for patients with PLE due to failed lymph drainage mechanisms than for those with PLE due to direct mucosal damage. Scintigraphy can help localize the leakage point and determine disease severity to guide PLE management.
- 28 August 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (1) , 136-147
Initial Ultrasound for Meckel's Diverticulum and Duplication Cyst in Pediatric Patients: Diagnostic Performance, Limitations, and Pitfalls
Purpose: To evaluate the diagnostic performance of ultrasound in detecting Meckel's diverticulum ( MD ) and duplication cysts ( DC ) and to identify factors influencing diagnostic accuracy. Methods: Among 66 patients with MD or DCs , we assessed the effect of symptom presence, atypical complications (hemoperitoneum, perforation, or acute pancreatitis), and lesion shape (tubular or cystic) on initial sonographic diagnostic accuracy using Fisher's exact test. Results: Initial ultrasound correctly diagnosed 49.9% (27/66) of cases. Correct diagnosis rates differed significantly between MD and DC (11/17 vs. 33/5, p < 0.001) and between tubular and cystic lesions (13/15 vs. 36/2, p < 0.001). No significant differences were observed for symptomatic versus asymptomatic cases (22/6 vs. 34/4, p = 0.302) or for cases with versus without atypical complications (1/27 vs. 5/33, p = 0.230). However, all DC cases with atypical complications were misdiagnosed on ultrasound. Conclusion: Ultrasound demonstrated reliable diagnostic performance for DCs ; however, MDs were more challenging to identify. Consequently, when MDs are suspected on clinical grounds, additional imaging, such as Tc‐99m scintigraphy, should be considered. In patients with DCs , atypical complications, such as hemoperitoneum or acute pancreatitis, may obscure sonographic diagnosis. Sonographers should therefore include DCs in the differential diagnosis when these complications arise without an apparent etiology.
- 28 August 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (1) , 136-147
Initial Ultrasound for Meckel's Diverticulum and Duplication Cyst in Pediatric Patients: Diagnostic Performance, Limitations, and Pitfalls
Purpose: To evaluate the diagnostic performance of ultrasound in detecting Meckel's diverticulum ( MD ) and duplication cysts ( DC ) and to identify factors influencing diagnostic accuracy. Methods: Among 66 patients with MD or DCs , we assessed the effect of symptom presence, atypical complications (hemoperitoneum, perforation, or acute pancreatitis), and lesion shape (tubular or cystic) on initial sonographic diagnostic accuracy using Fisher's exact test. Results: Initial ultrasound correctly diagnosed 49.9% (27/66) of cases. Correct diagnosis rates differed significantly between MD and DC (11/17 vs. 33/5, p < 0.001) and between tubular and cystic lesions (13/15 vs. 36/2, p < 0.001). No significant differences were observed for symptomatic versus asymptomatic cases (22/6 vs. 34/4, p = 0.302) or for cases with versus without atypical complications (1/27 vs. 5/33, p = 0.230). However, all DC cases with atypical complications were misdiagnosed on ultrasound. Conclusion: Ultrasound demonstrated reliable diagnostic performance for DCs ; however, MDs were more challenging to identify. Consequently, when MDs are suspected on clinical grounds, additional imaging, such as Tc‐99m scintigraphy, should be considered. In patients with DCs , atypical complications, such as hemoperitoneum or acute pancreatitis, may obscure sonographic diagnosis. Sonographers should therefore include DCs in the differential diagnosis when these complications arise without an apparent etiology.