Modeling and Control of a 2-DoF Meso-Scale Continuum Robotic Tool for Pediatric Neurosurgery
- 4 November 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 37 (2) , 520-531
Abstract
This article introduces the analysis and control of a meso-scale two degree-of-freedom robotic endoscopic tool body for minimally invasive surgeries. The design of the robotic tool uses two types of a tendon-driven joint known as a bending flexure joint that allows us to control each degree-of-freedom by minimizing interjoint coupling by design. Pure kinematic modeling and control for these robots may not provide precise control performance due to kinematic uncertainties arising from tendon elongation, tendon slacking, gear backlash, etc. We propose a static model for each of the joints of the robotic tool that avoids several of these problems. Depending on the direction of tendon tension application, the proximal joint displays considerable hysteresis due to the superelastic material characteristics and this is included in our static model. The statics of a highly compliant distal joint is also modeled and validated using finite element analysis and experimental data. Using these models, we develop a control system that comprises of a disturbance observer and the proposed static model to provide precise force control and compensate for joint hysteresis.Keywords
Funding Information
- Children's Healthcare of Atlanta
This publication has 40 references indexed in Scilit:
- General Principles and Intraventricular Neuroendoscopy: Endoscopic TechniquesWorld Neurosurgery, 2013
- Indication for Endoscopic Third VentriculostomyWorld Neurosurgery, 2013
- Solid, shape recovered “bulk” Nitinol: Part I—Tension–compression asymmetryMaterials Science and Engineering: A, 2011
- Development of minimally invasive medical tools using laser processing on cylindrical substratesElectrical Engineering in Japan, 2011
- Emerging technology in intracranial neuroendoscopy: application of the NICO MyriadNeurosurgical Focus, 2011
- Endoscopic Third Ventriculostomy in the Treatment of Childhood HydrocephalusThe Journal of Pediatrics, 2009
- A NEW MULTIPURPOSE VENTRICULOSCOPENeurosurgery, 2008
- Experimental study on the anisotropic behavior of textured NiTi pseudoelastic shape memory alloysMaterials Science and Engineering: A, 2003
- An experimental study of the superelastic effect in a shape-memory Nitinol alloy under biaxial loadingMechanics of Materials, 2003
- Geometric and material parameters of a nickel-titanium and a beta titanium orthodontic arch wire alloyDental Materials, 1987