Yash Chitalia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yash Chitalia has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jaydev P. Desai
Georgia Institute of Technology
1 shared publication - Joshua J. Chern
Pediatric Neurosurgery Associates, Children's Healthcare of Atlanta
1 shared publication - Kent K. Yamamoto
Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
1 shared publication - Seokhwan Jeong
Department of Mechanical Engineering, Sogang University, Seoul, South Korea
1 shared publication
Latest Publications
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 37 (2) , 520-531
Modeling and Control of a 2-DoF Meso-Scale Continuum Robotic Tool for Pediatric Neurosurgery
This article introduces the analysis and control of a meso-scale two degree-of-freedom robotic endoscopic tool body for minimally invasive surgeries. The design of the robotic tool uses two types of a tendon-driven joint known as a bending flexure joint that allows us to control each degree-of-freedom by minimizing interjoint coupling by design. Pure kinematic modeling and control for these robots may not provide precise control performance due to kinematic uncertainties arising from tendon elongation, tendon slacking, gear backlash, etc. We propose a static model for each of the joints of the robotic tool that avoids several of these problems. Depending on the direction of tendon tension application, the proximal joint displays considerable hysteresis due to the superelastic material characteristics and this is included in our static model. The statics of a highly compliant distal joint is also modeled and validated using finite element analysis and experimental data. Using these models, we develop a control system that comprises of a disturbance observer and the proposed static model to provide precise force control and compensate for joint hysteresis.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 37 (2) , 520-531
Modeling and Control of a 2-DoF Meso-Scale Continuum Robotic Tool for Pediatric Neurosurgery
This article introduces the analysis and control of a meso-scale two degree-of-freedom robotic endoscopic tool body for minimally invasive surgeries. The design of the robotic tool uses two types of a tendon-driven joint known as a bending flexure joint that allows us to control each degree-of-freedom by minimizing interjoint coupling by design. Pure kinematic modeling and control for these robots may not provide precise control performance due to kinematic uncertainties arising from tendon elongation, tendon slacking, gear backlash, etc. We propose a static model for each of the joints of the robotic tool that avoids several of these problems. Depending on the direction of tendon tension application, the proximal joint displays considerable hysteresis due to the superelastic material characteristics and this is included in our static model. The statics of a highly compliant distal joint is also modeled and validated using finite element analysis and experimental data. Using these models, we develop a control system that comprises of a disturbance observer and the proposed static model to provide precise force control and compensate for joint hysteresis.