Electro‐oxidation and simultaneous determination of amlodipine and atorvastatin in commercial tablets using carbon nanotube modified electrode
Open Access
- 1 August 2013
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in Micro & Nano Letters
- Vol. 8 (8) , 413-417
Abstract
Amlodipine besylate and atorvastatin calcium have been determined by the simultaneous voltammetric method at a multi‐walled carbon nanotubes:graphite (MWCNTs:G) paste electrode. In comparison with a glassy carbon electrode, the prepared electrode showed an increase in the peak current because of the high electroactive surface area and excellent electronic conductivity of MWCNTs. The dependence of currents and potentials on pH were investigated for these components at the surface of the MWCNTs:G paste electrode. Differential pulse voltammetry was applied as a sensitive technique for simultaneous determination of the drugs in commercial tablets. By anodic differential pulse voltammetry, the calibration plot was linear in the range of 2.5–100 µg/ml with standard deviation between 2.7–7.1 and 1.8–8.3% for amlodipine and atorvastatin, respectively. The detection limit was 1 µg/ml at the prepared electrode in the buffered solution pH 6.Keywords
This publication has 24 references indexed in Scilit:
- Direct electrochemistry and electrocatalysis of immobilised cytochrome c on electrodeposited nanoparticles for the reduction of oxygenMicro & Nano Letters, 2012
- Relation between conductance, photoluminescence bands and structure of ITO nanoparticles prepared by various chemical methodsMicro & Nano Letters, 2011
- Synthesis of Er2O3 Nanoparticles and Er2O3 Nanoparticle/Polyaniline Deposition on the Surface of Stainless Steel by Potentiostatic DepositionChemical Engineering & Technology, 2010
- Voltammetric determination of amlodipine besylate in human urine and pharmaceuticalsBioelectrochemistry, 2010
- Electroanalytical Studies and Simultaneous Determination of Amlodipine Besylate and Atorvastatine Calcium in Binary Mixtures Using First Derivative of the Ratio‐Voltammetric MethodsElectroanalysis, 2009
- Use of adsorptive square-wave anodic stripping voltammetry at carbon paste electrode for the determination of amlodipine besylate in pharmaceutical preparationsJournal of Analytical Chemistry, 2009
- Development of a stability‐indicating CE assay for the determination of amlodipine enantiomers in commercial tabletsElectrophoresis, 2008
- Determination of atorvastatin in human serum by reversed-phase high-performance liquid chromatography with UV detectionJournal of Chromatography B, 2005
- Determination of amlodipine besylate by adsorptive square-wave anodic stripping voltammetry on glassy carbon electrode in tablets and biological fluidsTalanta, 2004
- An HPLC method for the determination of atorvastatin and its impurities in bulk drug and tabletsJournal of Pharmaceutical and Biomedical Analysis, 2003