Interference between Active Implanted Medical Devices and Electromagnetic Field Emitting Devices is Rare but Real: Results of an Incidence Study in a Population of Physicians in France
Authors:
- 13 September 2013
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 37 (3) , 290-296
Abstract
Background and Objective: Assessing the behavior of active implanted medical devices (AIMDs) in response to electromagnetic field (EMF) transmitters is a current issue of great importance. Given the numerous telecommunication systems and our lack of knowledge as to the impact of electromagnetic effects, this study investigated the reality of possible AIMD disturbance by EMFs by interviewing health professionals.Method: A self‐administered postal questionnaire was sent to almost 5,000 physicians in five specialties: cardiology; endocrinology; ears, nose, and throat; urology; and neurology. It collected data on the existence and annual number of incidents observed and the conditions under which they occurred, the EMF sources involved, and the means of managing the malfunctions.Results: A total of 1,188 physicians agreed to participate. Sixteen percent of participants reported cases of implant failure, three‐quarters of whom, mainly in cardiology, reported rates of at least one incident per year—amounting to more than 100 incidents per year in all. Severity appeared to be moderate (discomfort or transient symptoms), but frequently required resetting or, more rarely, replacing the device. Some serious incidents were, however, reported. The sources implicated were basically of two types: electronic security systems (antitheft and airport gates) and medical electromagnetic radiation devices. These incidents were poorly reported within the public health system, preventing follow‐up and effective performance of alert and surveillance functions.Conclusion: Although minor, the risk of interference between EMF sources and AIMDs is real and calls for vigilance. It particularly concerns antitheft and airport security gates, though other sources may also cause incidents.Keywords
This publication has 22 references indexed in Scilit:
- Intermittent, erratic behaviour of an implantable cardioverter defibrillator secondary to a hidden magnetic source of interferenceEP Europace, 2011
- Practice Advisory for the Perioperative Management of Patients with Cardiac Implantable Electronic Devices: Pacemakers and Implantable Cardioverter-DefibrillatorsAnesthesiology, 2011
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- Do Media Players Cause Interference with Pacemakers?Clinical Cardiology, 2009
- A Prospective Pediatric Clinical Trial of Digital Music Players: Do They Interfere with Pacemakers?Journal of Cardiovascular Electrophysiology, 2008
- Cochlear Implant Magnet Displacement During Magnetic Resonance ImagingOtology & Neurotology, 2008
- Low frequency magnetic emissions and resulting induced voltages in a pacemaker by iPod portable music playersBioMedical Engineering OnLine, 2008
- Effects of Mobile Telephones on the Function of Implantable Cardioverter DefibrillatorsAnnals of Noninvasive Electrocardiology, 2005
- Practice Advisory for the Perioperative Management of Patients with Cardiac Rhythm Management Devices: Pacemakers and Implantable Cardioverter–DefibrillatorsAnesthesiology, 2005
- Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators?JACC, 2003