Association of Pulsatility with Gastrointestinal Bleeding in a Cohort of HeartMate II Recipients
Authors:
- 1 July 2018
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 64 (4) , 472-479
Abstract
Gastrointestinal bleeding (GIB) is common in patients with continuous-flow left ventricular assist devices (CF-LVADs) possibly because of changes in blood flow. We aimed to test the hypothesis that a low pulsatility index (PI) is associated with an increased hazard of overt GIB in patients with CF-LVADs. We conducted a retrospective cohort study of patients who had a HeartMate II (HMII) CF-LVAD implanted at our center. The study end-point was the first overt GIB causing or occurring during a hospitalization between 6 days and 6 months after HMII implantation. HMII PI was recorded at 48 hours and at 1, 3, and 6 month intervals after implantation. We analyzed the associations of PI and clinical variables with the hazard of overt GIB. Ninety-five patients met eligibility criteria. PI ranged from 2.5 to 5.9 (low PI < 4.15 and high PI ≥ 4.15 on the basis of receiver operating characteristic curve analysis). Seventeen (18%) patients experienced overt GIB. In a multivariable model, only lower baseline hemoglobin was a significant predictor of an increased hazard of overt GIB. After adjusting for the baseline hemoglobin, low PI was independently associated with an increased hazard of overt GIB in our cohort of HMII recipients.Keywords
This publication has 32 references indexed in Scilit:
- Gastrointestinal Bleeding in Patients with Ventricular Assist Devices Is Highest Immediately After ImplantationASAIO Journal, 2013
- Pulsatility and the Risk of Nonsurgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate IICirculation: Heart Failure, 2013
- VON WILLEBRAND FACTOR, ANGIODYSPLASIA AND ANGIOGENESISMediterranean Journal of Hematology and Infectious Diseases, 2013
- Results of HeartMate II left ventricular assist device implantation on renal function in patients requiring post-implant renal replacement therapyThe Journal of Heart and Lung Transplantation, 2011
- Unforeseen Consequences of Therapy With Continuous-Flow PumpsCirculation: Heart Failure, 2010
- Management Options to Treat Gastrointestinal Bleeding in Patients Supported on Rotary Left Ventricular Assist Devices: A Single‐Center ExperienceArtificial Organs, 2010
- Increased Incidence of Gastrointestinal Bleeding Following Implantation of the HeartMate II LVADJournal of Cardiac Surgery, 2010
- Gastrointestinal Bleeding in Older AdultsClinics in Geriatric Medicine, 2007
- Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist deviceThe Journal of Heart and Lung Transplantation, 2005
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureThe New England journal of medicine, 2001