WF-PPG: A Wrist-finger Dual-Channel Dataset for Studying the Impact of Contact Pressure on PPG Morphology
Top Cited Papers
Open Access
- 3 February 2025
- journal article
- research article
- Published by Springer Nature in Scientific Data
- Vol. 12 (1) , 1-11
Abstract
Photoplethysmography (PPG) is a simple optical technique widely used in wearable devices for continuous cardiac health monitoring. However, the quality of PPG signals, particularly their morphology, is influenced by the contact pressure between the skin and the sensor. This variability in signal quality complicates complex tasks that rely on high-quality signals, such as blood pressure and heart rate variability estimation, making them less reliable or even impossible. To address this issue, we present a novel dataset (termed WF-PPG) comprising PPG signals from the wrist measured under varying contact pressures, along with high-quality PPG signals from the fingertip captured simultaneously. Data collection was conducted using a custom device setup capable of precisely adjusting the contact pressure for wrist PPG signals while also recording additional metrics such as contact pressure, electrocardiogram (ECG), blood pressure, and oxygen saturation. WF-PPG is designed to facilitate the analysis of effects of contact pressure on PPG morphology and to support the development and evaluation of advanced data-driven techniques aimed at enhancing the reliability of PPG-based health monitoring.Keywords
This publication has 38 references indexed in Scilit:
- Investigating the impact of contact pressure on photoplethysmogramsBiomedical Engineering Advances, 2024
- Wearable wrist to finger photoplethysmogram translation through restoration using super operational neural networks based 1D-CycleGAN for enhancing cardiovascular monitoringExpert Systems with Applications, 2024
- EarSet: A Multi-Modal Dataset for Studying the Impact of Head and Facial Movements on In-Ear PPG SignalsScientific Data, 2023
- Photoplethysmograhic sensors, potential and limitations: Is it time for regulation? A comprehensive reviewMeasurement, 2023
- Prediction of vascular aging based on smartphone acquired PPG signalsScientific Reports, 2020
- Heart rate estimation from photoplethysmography signal for wearable health monitoring devicesBiomedical Signal Processing and Control, 2019
- Current progress of photoplethysmography and SPO2 for health monitoringBiomedical Engineering Letters, 2019
- New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoringScientific Reports, 2016
- Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sitesPhysiological Measurement, 2003
- Determination of age-related increases in large artery stiffness by digital pulse contour analysisClinical Science, 2002