Dong Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dong Ma has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Cecilia Mascolo
Department of Computer Science and Technology, University of Cambridge, Cambridge, United Kingdom
14 shared publications - Guohao Lan
Delft University of Technology
12 shared publications - Wen Hu
University of New South Wales
11 shared publications - Yang Liu
Florida State University, Tallahassee, USA
10 shared publications - Changshuo Hu
Singapore Management University, Singapore, Singapore
9 shared publications - Jake Stuchbury-Wass
Department of Computer Science and Technology, University of Cambridge, Cambridge, United Kingdom
9 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (3) , 1-27
PPG-IDR: Leveraging User Identity for Robust Cross-user PPG Sensing via Disentangled Representations
Photoplethysmography (PPG) is widely used in non-invasive health monitoring applications such as heart rate and blood pressure estimation. Despite deep learning substantially advancing PPG sensing accuracy, models trained on a population often struggle with cross-user generalization , exhibiting significant performance degradation when applied to unseen individuals. Building on the evidence that PPG signals encode biometric traits for user authentication, we hypothesize that these identity-specific features are a primary confounding noise of poor cross-user generalization. To validate this hypothesis and address the issue, we propose PPG-IDR (Identity Disentangled Representations), a framework designed to disentangle medical physiological features from identity-specific information. PPG-IDR utilizes a dual-branch design to partition the feature space, employing adversarial and orthogonality constraints to suppress identity leakage, alongside a self-supervised objective to refine medical representations. We evaluated PPG-IDR using multiple datasets across six downstream tasks, and the results demonstrate that PPG-IDR consistently outperforms strong baselines in unseen-user scenarios. These findings highlight the importance of identity disentanglement for scalable and robust cross-user PPG sensing.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (3) , 1-27
Open AccessPPG-IDR: Leveraging User Identity for Robust Cross-user PPG Sensing via Disentangled Representations
Photoplethysmography (PPG) is widely used in non-invasive health monitoring applications such as heart rate and blood pressure estimation. Despite deep learning substantially advancing PPG sensing accuracy, models trained on a population often struggle with cross-user generalization , exhibiting significant performance degradation when applied to unseen individuals. Building on the evidence that PPG signals encode biometric traits for user authentication, we hypothesize that these identity-specific features are a primary confounding noise of poor cross-user generalization. To validate this hypothesis and address the issue, we propose PPG-IDR (Identity Disentangled Representations), a framework designed to disentangle medical physiological features from identity-specific information. PPG-IDR utilizes a dual-branch design to partition the feature space, employing adversarial and orthogonality constraints to suppress identity leakage, alongside a self-supervised objective to refine medical representations. We evaluated PPG-IDR using multiple datasets across six downstream tasks, and the results demonstrate that PPG-IDR consistently outperforms strong baselines in unseen-user scenarios. These findings highlight the importance of identity disentanglement for scalable and robust cross-user PPG sensing.
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (3) , 1-27
Hearing Your Calories: Short-Session Calibrated Energy Expenditure Monitoring via Earable Respiratory Sensing
Accurate monitoring of energy expenditure (EE) during exercise is crucial for health management, fitness optimization, and clinical assessment. Although many commercial wearables offer EE levels as a standard feature, they typically rely on simple regressions of heart rate, motion trajectory, or activity intensity. Consequently, such models inherently struggle with cross-activity generalization and demand massive labeled data, leading to significant accuracy degradation in practical deployment. To address this, we propose EarEE, a novel earable system that estimates EE by decoding exercise-associated respiratory sounds into oxygen consumption and carbon dioxide production, which are gold-standard metabolic indicators of EE. EarEE advances existing technologies through three key innovations: i) Dynamics-Aware Deep Modeling , which captures the nonlinear temporal and contextual relationship between respiratory acoustics and gas exchange; ii) Generative Data Synthesis , which expands data from a short calibration session into diverse and realistic respiratory profiles, enabling robust model training with limited labeled data; and iii) Heart Sounds Suppression , which mitigates heart sound artifacts for reliable estimation during intensive activities. Extensive evaluations with 42 participants across 7 exercises demonstrate that EarEE achieves an average relative error of 10.95%, significantly outperforming wearable solutions and approaching the 10% clinical accuracy benchmark, highlighting its potential for practical daily EE monitoring.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (3) , 1-27
Open AccessHearing Your Calories: Short-Session Calibrated Energy Expenditure Monitoring via Earable Respiratory Sensing
Accurate monitoring of energy expenditure (EE) during exercise is crucial for health management, fitness optimization, and clinical assessment. Although many commercial wearables offer EE levels as a standard feature, they typically rely on simple regressions of heart rate, motion trajectory, or activity intensity. Consequently, such models inherently struggle with cross-activity generalization and demand massive labeled data, leading to significant accuracy degradation in practical deployment. To address this, we propose EarEE, a novel earable system that estimates EE by decoding exercise-associated respiratory sounds into oxygen consumption and carbon dioxide production, which are gold-standard metabolic indicators of EE. EarEE advances existing technologies through three key innovations: i) Dynamics-Aware Deep Modeling , which captures the nonlinear temporal and contextual relationship between respiratory acoustics and gas exchange; ii) Generative Data Synthesis , which expands data from a short calibration session into diverse and realistic respiratory profiles, enabling robust model training with limited labeled data; and iii) Heart Sounds Suppression , which mitigates heart sound artifacts for reliable estimation during intensive activities. Extensive evaluations with 42 participants across 7 exercises demonstrate that EarEE achieves an average relative error of 10.95%, significantly outperforming wearable solutions and approaching the 10% clinical accuracy benchmark, highlighting its potential for practical daily EE monitoring.
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (3) , 1-25
ImpactEar: Cross Activity Ground Reaction Force Estimation using Earable IMUs
Ground Reaction Forces (GRFs) are the forces exerted between the foot and the ground during movement. They are key biomechanical indicators for gait monitoring, injury recovery tracking, and sporting performance. Traditional force plates provide gold-standard accuracy but are expensive and confined to laboratories, while leg- or foot-mounted devices require specialised hardware and sacrifice user comfort. Recent work utilising commodity devices such as smartwatches and earphones offer greater accessibility, yet wrist sensors suffer from arm-swing artifacts and existing earable studies remain activity-specific, limited to either walking or running (and never both) as GRF patterns differ drastically across locomotion types. In this paper, we propose ImpactEar, the first system to estimate complete GRF curves across multiple activities using only a pair of earable inertial measurement units (IMUs). Our core insight is to treat the head as a proxy for the body's center of mass and leverage bilateral earable IMUs to capture both translational and rotational dynamics. Combined with temporal context modeling, this enables a cross-activity mapping from head motion to GRF curves with a single model. ImpactEar employs a lightweight encoder-decoder network that reconstructs left-right GRF profiles across walking, running, and jumping in real time. The evaluation on 30 participants shows that ImpactEar achieves 8.6% normalized root mean square error (NRMSE) and 9.5 ms latency on a mobile phone streaming earable IMU data, outperforming state-of-the-art single-activity baselines and remaining robust under practical conditions, such as reduced sampling rates, single earbuds, different ground surfaces, music playback and head and facial motions. We further demonstrate the power of a cross activity model over a range of different downstream applications including gait asymmetry analysis, jump power assessment, and ballet motion evaluation. Finally, we release ImpactEarDS, the first public earable-GRF dataset with synchronised IMU and force-plate ground truth, paving the way for ubiquitous human kinetics and biomechanics research.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (3) , 1-25
Open AccessImpactEar: Cross Activity Ground Reaction Force Estimation using Earable IMUs
Ground Reaction Forces (GRFs) are the forces exerted between the foot and the ground during movement. They are key biomechanical indicators for gait monitoring, injury recovery tracking, and sporting performance. Traditional force plates provide gold-standard accuracy but are expensive and confined to laboratories, while leg- or foot-mounted devices require specialised hardware and sacrifice user comfort. Recent work utilising commodity devices such as smartwatches and earphones offer greater accessibility, yet wrist sensors suffer from arm-swing artifacts and existing earable studies remain activity-specific, limited to either walking or running (and never both) as GRF patterns differ drastically across locomotion types. In this paper, we propose ImpactEar, the first system to estimate complete GRF curves across multiple activities using only a pair of earable inertial measurement units (IMUs). Our core insight is to treat the head as a proxy for the body's center of mass and leverage bilateral earable IMUs to capture both translational and rotational dynamics. Combined with temporal context modeling, this enables a cross-activity mapping from head motion to GRF curves with a single model. ImpactEar employs a lightweight encoder-decoder network that reconstructs left-right GRF profiles across walking, running, and jumping in real time. The evaluation on 30 participants shows that ImpactEar achieves 8.6% normalized root mean square error (NRMSE) and 9.5 ms latency on a mobile phone streaming earable IMU data, outperforming state-of-the-art single-activity baselines and remaining robust under practical conditions, such as reduced sampling rates, single earbuds, different ground surfaces, music playback and head and facial motions. We further demonstrate the power of a cross activity model over a range of different downstream applications including gait asymmetry analysis, jump power assessment, and ballet motion evaluation. Finally, we release ImpactEarDS, the first public earable-GRF dataset with synchronised IMU and force-plate ground truth, paving the way for ubiquitous human kinetics and biomechanics research.
- Open Access
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (2) , 1-41
A Survey of Earable Technology: Trends, Tools, and the Road Ahead
Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We attempt to answer three core questions: (1) how has earable research evolved in recent years, (2) what enabling resources are now available, and (3) what opportunities remain for future exploration. For question (1), we analyze over one hundred recent studies to characterize this shifting research landscape, by identifying emerging sensing principles / applications, and efforts to improve accuracy and reliability over prior works. For question (2), we summarize new public datasets and hardware platforms that can be leveraged to facilitate future earable research. Finally, for question (3), we discuss open challenges and propose future directions for the next phase of earable research.
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (2) , 1-41
Open AccessA Survey of Earable Technology: Trends, Tools, and the Road Ahead
Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We attempt to answer three core questions: (1) how has earable research evolved in recent years, (2) what enabling resources are now available, and (3) what opportunities remain for future exploration. For question (1), we analyze over one hundred recent studies to characterize this shifting research landscape, by identifying emerging sensing principles / applications, and efforts to improve accuracy and reliability over prior works. For question (2), we summarize new public datasets and hardware platforms that can be leveraged to facilitate future earable research. Finally, for question (3), we discuss open challenges and propose future directions for the next phase of earable research.
- Open Access
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (2) , 1-28
PPG-Sport: A Dataset for Reliable Heart Rate Monitoring from Wrist PPG Under Dynamic Sports Conditions
Photoplethysmography (PPG) has become a cornerstone of physiological sensing in wearable devices, enabling non-invasive monitoring of heart rate and related biomarkers. However, its reliability deteriorates sharply under dynamic, high-intensity, or non-periodic motions such as those in sports, where existing datasets fail to capture realistic wrist dynamics. To address this gap, we introduce PPG-Sport, the first large-scale dataset designed for heart rate monitoring from wrist-worn PPG under real sports conditions. The PPG-Sport dataset includes synchronized PPG, inertial measurement unit (IMU), and electrocardiography (ECG) recordings from both wrists of 30 participants across six representative activities: stationary, walking, running, badminton, table tennis, and basketball, amounting to 48 hours of multimodal data. PPG-Sport uniquely captures three critical properties absent in prior datasets: (1) non-periodicity, reflecting irregular and broadband motion patterns; (2) high intensity, with frequent, large-magnitude accelerations; and (3) bilateral asymmetry, caused by distinct functional roles of the dominant and non-dominant hands during sports. We further establish a deep-learning-based benchmark that combines both temporal and spectral representations of PPG and IMU signals to evaluate heart rate estimation performance. Experimental results show that models trained only on conventional periodic activities fail drastically in sports scenarios. Although incorporating sports data mitigates the degradation, significant errors remain. These findings highlight PPG-Sport as an essential and challenging benchmark for developing motion-robust physiological sensing algorithms during sports activities. Dataset and benchmark code are available at: https://github.com/LaserHu/PPG-Sport.
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10  (2) , 1-28
Open AccessPPG-Sport: A Dataset for Reliable Heart Rate Monitoring from Wrist PPG Under Dynamic Sports Conditions
Photoplethysmography (PPG) has become a cornerstone of physiological sensing in wearable devices, enabling non-invasive monitoring of heart rate and related biomarkers. However, its reliability deteriorates sharply under dynamic, high-intensity, or non-periodic motions such as those in sports, where existing datasets fail to capture realistic wrist dynamics. To address this gap, we introduce PPG-Sport, the first large-scale dataset designed for heart rate monitoring from wrist-worn PPG under real sports conditions. The PPG-Sport dataset includes synchronized PPG, inertial measurement unit (IMU), and electrocardiography (ECG) recordings from both wrists of 30 participants across six representative activities: stationary, walking, running, badminton, table tennis, and basketball, amounting to 48 hours of multimodal data. PPG-Sport uniquely captures three critical properties absent in prior datasets: (1) non-periodicity, reflecting irregular and broadband motion patterns; (2) high intensity, with frequent, large-magnitude accelerations; and (3) bilateral asymmetry, caused by distinct functional roles of the dominant and non-dominant hands during sports. We further establish a deep-learning-based benchmark that combines both temporal and spectral representations of PPG and IMU signals to evaluate heart rate estimation performance. Experimental results show that models trained only on conventional periodic activities fail drastically in sports scenarios. Although incorporating sports data mitigates the degradation, significant errors remain. These findings highlight PPG-Sport as an essential and challenging benchmark for developing motion-robust physiological sensing algorithms during sports activities. Dataset and benchmark code are available at: https://github.com/LaserHu/PPG-Sport.
- Open Access
- 10 May 2026
- Published by Association for Computing Machinery (ACM)
- p. 1343-1356
From Cheap to Chic: Enhancing Music Playback Quality of Budget Earphones via Hardware-Aware Learning
- 10 May 2026
- Published by Association for Computing Machinery (ACM)
- p. 1343-1356
Open AccessFrom Cheap to Chic: Enhancing Music Playback Quality of Budget Earphones via Hardware-Aware Learning
- Open Access
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-22
BAIT: Visual-illusion-inspired Privacy Preservation for Mobile Data Visualization
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-22
Open AccessBAIT: Visual-illusion-inspired Privacy Preservation for Mobile Data Visualization
- Open Access
- 25 February 2026
- Published by Association for Computing Machinery (ACM)
- p. 103-108
EarCalo: Earable-Based Energy Expenditure Estimation While Running
Accurately estimating energy expenditure (EE) is crucial for understanding exercise efficiency, managing fitness goals, and monitoring health conditions. Existing wearable systems either rely primarily on heart rate and motion sensors, resulting in unsatisfactory accuracy, or require bulky setups such as thermal cameras to improve performance by integrating more physiological information, which limits real-world applicability. We present EarCalo, an earable-based system that leverages in-ear audio sensing to estimate EE during running. The system extracts airflow-induced acoustic variations within the ear canal and employs a deep neural network to translate these subtle in-ear sound dynamics into EE estimates. The key insight is that in-ear acoustic signals can capture multiple physiological factors such as breathing and cardiovascular activity, while also reflecting motion-related cues like running intensity. These rich acoustic cues are closely related to EE and provide a unified sensing modality for estimation. We evaluated EarCalo on 21 participants running at varying speeds using a mixed-user setting. EarCalo achieved a mean absolute error (MAE) of 0.67 kcal/min, a mean absolute percentage error (MAPE) of 11.98%, and a Pearson correlation of 0.945, which achieves accuracy close to established physiological standards. This work represents an early step toward practical and personalized earable-based EE estimation in everyday settings.
- 25 February 2026
- Published by Association for Computing Machinery (ACM)
- p. 103-108
Open AccessEarCalo: Earable-Based Energy Expenditure Estimation While Running
Accurately estimating energy expenditure (EE) is crucial for understanding exercise efficiency, managing fitness goals, and monitoring health conditions. Existing wearable systems either rely primarily on heart rate and motion sensors, resulting in unsatisfactory accuracy, or require bulky setups such as thermal cameras to improve performance by integrating more physiological information, which limits real-world applicability. We present EarCalo, an earable-based system that leverages in-ear audio sensing to estimate EE during running. The system extracts airflow-induced acoustic variations within the ear canal and employs a deep neural network to translate these subtle in-ear sound dynamics into EE estimates. The key insight is that in-ear acoustic signals can capture multiple physiological factors such as breathing and cardiovascular activity, while also reflecting motion-related cues like running intensity. These rich acoustic cues are closely related to EE and provide a unified sensing modality for estimation. We evaluated EarCalo on 21 participants running at varying speeds using a mixed-user setting. EarCalo achieved a mean absolute error (MAE) of 0.67 kcal/min, a mean absolute percentage error (MAPE) of 11.98%, and a Pearson correlation of 0.945, which achieves accuracy close to established physiological standards. This work represents an early step toward practical and personalized earable-based EE estimation in everyday settings.
- Open Access
- 1 January 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42  (5) , 1-10
Ear-Worn Inertial Sensors Can Predict Gait Metrics and Reconstruct Vertical Ground Reaction Force Curves During Running
Ear-worn wearables (aka: earbuds, hearables, or earables) are commonly used by runners for entertainment, and many modern devices also include inertial sensors for user interaction. We propose harnessing the technology embedded in earbuds to capture fundamental aspects of running mechanics and make them available to the wider community of users, outside a lab setting. While other wearables such as insoles or ankle-/sacrum-mounted inertial measurement units have already been presented, ear-worn devices may have a better potential for adoption and therefore offer an optimal compromise between validity of running gait analysis and usability. Thirty healthy participants (18 males, 12 females) ran on an instrumented treadmill (54,000 gait cycles) and floor-mounted force plates (2800 gait cycles) at a variety of speeds. Building on the information brought about by the vibrations transmitted to, and motion of, the head, we devised a gait event detection algorithm and a regression model to predict vertical ground reaction force waveforms. The validation of outcomes against quantities from force plates shows an average mean absolute percentage error of 4.8% on temporal metrics and 9.0% on scalar ground reaction force derived metrics. Additionally, the model tracks the full vertical ground reaction force curve well, achieving an normalized root mean square error of 11.1% on unseen participants. Overall, we show comparable accuracy from an ear-worn consumer device in temporal and kinetic gait parameter estimation to specialist devices, paving the way for accessible running gait monitoring.
- 1 January 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42  (5) , 1-10
Open AccessEar-Worn Inertial Sensors Can Predict Gait Metrics and Reconstruct Vertical Ground Reaction Force Curves During Running
Ear-worn wearables (aka: earbuds, hearables, or earables) are commonly used by runners for entertainment, and many modern devices also include inertial sensors for user interaction. We propose harnessing the technology embedded in earbuds to capture fundamental aspects of running mechanics and make them available to the wider community of users, outside a lab setting. While other wearables such as insoles or ankle-/sacrum-mounted inertial measurement units have already been presented, ear-worn devices may have a better potential for adoption and therefore offer an optimal compromise between validity of running gait analysis and usability. Thirty healthy participants (18 males, 12 females) ran on an instrumented treadmill (54,000 gait cycles) and floor-mounted force plates (2800 gait cycles) at a variety of speeds. Building on the information brought about by the vibrations transmitted to, and motion of, the head, we devised a gait event detection algorithm and a regression model to predict vertical ground reaction force waveforms. The validation of outcomes against quantities from force plates shows an average mean absolute percentage error of 4.8% on temporal metrics and 9.0% on scalar ground reaction force derived metrics. Additionally, the model tracks the full vertical ground reaction force curve well, achieving an normalized root mean square error of 11.1% on unseen participants. Overall, we show comparable accuracy from an ear-worn consumer device in temporal and kinetic gait parameter estimation to specialist devices, paving the way for accessible running gait monitoring.
- Open Access
- 17 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15  (1)
Reliable wrist PPG monitoring by mitigating poor skin sensor contact
Photoplethysmography (PPG) is a widely used non-invasive technique for monitoring cardiovascular health and various physiological parameters on consumer and medical devices. While motion artifacts are well-known challenges in dynamic settings, suboptimal skin-sensor contact in sedentary conditions - an important issue often overlooked in existing literature - can distort PPG signal morphology, leading to the loss or shift of essential waveform features and therefore degrading sensing performance. In this work, we propose a deep learning-based framework that transforms C ontact P ressure-distorted PPG signals into ones with the ideal morphology, known as CP-PPG. CP-PPG incorporates a well-crafted data processing pipeline and an adversarially trained deep generative model, together with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild performance. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues for accurate and reliable PPG-based physiological monitoring. Our implementation is publicly available at: https://github.com/manhph2211/CP-PPG .
- 17 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15  (1)
Open AccessReliable wrist PPG monitoring by mitigating poor skin sensor contact
Photoplethysmography (PPG) is a widely used non-invasive technique for monitoring cardiovascular health and various physiological parameters on consumer and medical devices. While motion artifacts are well-known challenges in dynamic settings, suboptimal skin-sensor contact in sedentary conditions - an important issue often overlooked in existing literature - can distort PPG signal morphology, leading to the loss or shift of essential waveform features and therefore degrading sensing performance. In this work, we propose a deep learning-based framework that transforms C ontact P ressure-distorted PPG signals into ones with the ideal morphology, known as CP-PPG. CP-PPG incorporates a well-crafted data processing pipeline and an adversarially trained deep generative model, together with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild performance. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues for accurate and reliable PPG-based physiological monitoring. Our implementation is publicly available at: https://github.com/manhph2211/CP-PPG .