Left Ventricular Function Can Reliably be Assessed From Dual-Source CT Using ECG-Gated Tube Current Modulation
Authors:
- Andreas H. MahnkenAMAndreas H. Mahnken
- Philipp BrunersPBPhilipp Bruners
- Bernhard SchmidtBSBernhard Schmidt
- Christoph BornikoelCBChristoph Bornikoel
- Thomas FlohrTFThomas Flohr
- Rolf W. GüntherRGRolf W. Günther
- 1 July 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 44 (7) , 384-389
Abstract
The aim of this study was to assess the reliability of global left ventricular (LV) function analysis using dual source CT (DSCT) with and without ECG-gated tube current modulation in comparison with magnetic resonance (MR) imaging. In 7 pigs with myocardial infarction retrospectively ECG-gated DSCT (2 × 64 × 0.6 mm; 120kV; 380mAsrot.) with and without tube current modulation (gating window: 40%–75%) as well as cine MR imaging of the heart were performed on the same day. From DSCT data 6 mm double-oblique short axis images were computed. DSCT as well as MR images were analyzed using Simpson method. LV volumes, ejection fraction and, myocardial mass were calculated. Wall motion was assessed visually. Standard deviations of attenuation values measured in the LV cavity were assigned to image noise and compared using Wilcoxon test. LV volumes were compared with Lin concordance-correlation coefficient (ρc). Regional wall motion was analyzed with weighted kappa statistics. Both, DSCT with (DSCTDM) and without (DSCTnorm) dose modulation were in good agreement with MR imaging. For ejection fraction, there was an excellent concordance-correlation comparing DSCTnorm with DSCTDM (ρc = 0.9749), DSCTnorm with MR imaging (ρc = 0.9435), and DSCTDM with MR imaging (ρc = 0.9612). The corresponding kappa values comparing regional wall motion were κ = 0.988, κ = 0.901, and κ = 0.888, respectively. During end-systole there was no significant difference in the image noise between DSCTnorm and DSCTDM techniques (P = 0.8750), but the difference became significant when comparing end-diastolic DSCT images (P = 0.0156). ECG-gated tube-current modulation does not hamper the quantitative assessment of global and regional LV function using DSCT.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of Regional Versus Global Assessment of Left Ventricular Function in Patients with Left Ventricular Dysfunction, Heart Failure, or Both After Myocardial Infarction: The Valsartan in Acute Myocardial Infarction Echocardiographic StudyJournal of the American Society of Echocardiography, 2006
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005
- Left ventricular function studied with MDCTEuropean Radiology, 2005
- Effect of Acquisition Technique on Radiation Dose and Image Quality in Multidetector Row Computed Tomography Coronary Angiography With Submillimeter CollimationInvestigative Radiology, 2005
- Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarctionEuropean Radiology, 2005
- Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem GatingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Determinants of 6-month mortality in survivors of myocardial infarction after thrombolysis. Results of the GISSI-2 data base. The Ad hoc Working Group of the Gruppo Italiano per lo Studio della Sopravvivenza nell'Infarto Miocardico (GISSI)-2 Data Base.Circulation, 1993
- Transesophageal EchocardiographyJournal of the American Society of Echocardiography, 1989
- Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.Circulation, 1987
- Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations.Circulation, 1979