Dependence of brain‐tissue R2 on MRI field strength
Open Access
- 17 December 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 2140-2152
Abstract
Purpose: To quantify T2 relaxation in the brain at 3 T and 7 T to study its field dependence and correlation with iron content, and to investigate whether iron can be separated from other sources of T2 relaxation based on this field dependence.Methods: Nine subjects were scanned at both field strengths with the same acquisition technique, which used multiple gradient‐echo sampling of a spin echo. This allowed for separation of T2 relaxation from static dephasing by B0 field inhomogeneities and the effects of radiofrequency refocusing imperfections. The average relaxation rates (R2 = 1/T2) in multiple regions of interest in the brain were fitted with a model linear in B0 and correlated with literature iron values.Results: The relationship between the R2 values at the two field strengths appeared to be linear over all regions of interest. The R2 values (in s−1) in the regions of interest for which both an iron and a lipid mass fraction have been documented in the literature were fitted as , where and indicate the putative mass fractions of iron and lipid.Conclusion: The R2 relaxation rate is well described by a constant plus a term linear in B0, with both iron and lipid content contributing to the slope. This indicates that the contributions of lipid and iron to R2 cannot be separated based solely on the field dependence of R2 in the field range of 3–7 T.Keywords
Funding Information
- National Institute of Neurological Disorders and Stroke
This publication has 80 references indexed in Scilit:
- The Alzheimer's disease neuroimaging initiative (ADNI): MRI methodsJournal of Magnetic Resonance Imaging, 2008
- Anomalous nuclear magnetic relaxation of aqueous solutions of ferritin: An unprecedented first‐order mechanismMagnetic Resonance in Medicine, 2002
- In vivo 1H2O T measurement in the human occipital lobe at 4T and 7T by Carr‐Purcell MRI: Detection of microscopic susceptibility contrastMagnetic Resonance in Medicine, 2002
- On T2‐shortening by strongly magnetized spheres: A partial refocusing modelMagnetic Resonance in Medicine, 2002
- Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: Relation to estimated iron and water contentsMagnetic Resonance in Medicine, 2001
- Relaxation induced by ferritin and ferritin-like magnetic particles: The role of proton exchangeMagnetic Resonance in Medicine, 2000
- Increased iron in the dentate nucleus of patients with Friedreich's ataxiaAnnals of Neurology, 1999
- Comparison of t2 relaxation in blood, brain, and ferritinJournal of Magnetic Resonance Imaging, 1995
- Frequency dependence of MR relaxation times II. Iron oxidesJournal of Magnetic Resonance Imaging, 1993
- Metabolic anatomy of brain: A comparison of regional capillary density, glucose metabolism, and enzyme activitiesJournal of Comparative Neurology, 1989