PGPeter van Gelderen

Peter van Gelderen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter van Gelderen has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Jeff H. Duyn

    Advanced MRI Section NINDS, NIH Bethesda Maryland USA

    9 shared publications
  • Jacco Adrianus de Zwart

    National Institutes of Health, National Institute of Neurological Disorders and Stroke, Advanced Magnetic Resonance Imaging Section, Bethesda, USA

    7 shared publications
  • J.H. Duyn

    Advanced Magnetic Resonance Imaging Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, USA

    3 shared publications
  • Jacco A. de Zwart

    Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA

    3 shared publications
  • Yicun Wang

    Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States

    3 shared publications
  • J.A. de Zwart

    Advanced MRI, Laboratory of Functional and Molecular Imaging (LFMI), National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA

    2 shared publications

Latest Publications

  • Open Access

    Mesoscale Whole‐Brain T 2 *‐Weighted and Associated Quantitative MRI in Humans at 10.5 T

    by Jiaen Liu, Peter van Gelderen, Jacco A. de Zwart, Jeff H. Duyn, Yujia Huang, Shuxian Qu, Andrea Grant, Edward J. Auerbach, Matt Waks, Russell L. Lagore, et al.

    Purpose: To demonstrate mesoscale whole‐brain T 2 *‐weighted ( T 2 *w) MRI at 10.5 T, quantify R 2 * relaxation rate and magnetic susceptibility ( χ ), and evaluate T 2 *w contrast at such high field strength. Methods: Multi‐echo GRE (ME‐GRE) data were collected in healthy adults at 0.5 mm isotropic resolution at 10.5 T. Whole‐brain images were reconstructed with navigator‐guided joint motion and field correction and were used for quantitative R 2 * and χ mapping. Regional R 2 * and χ values and R 2 * contrast were analyzed in volumetric regions of interest (ROIs) and intra‐cortical surface‐based ROIs. For comparison, ME‐GRE data from the same subjects were acquired using a similar protocol at 7 T. Results: High‐quality whole‐brain T 2 *w images were obtained, enabling R 2 * and χ mapping with delineation of fine‐scale brain structures. Regional R 2 * analysis revealed a linear relationship between 10.5 T and 7 T R 2 * values with a slope of 1.52, in agreement with previously reported linear field dependency of R 2 *. Estimated χ values were field‐independent in most brain regions under consideration except for the basal ganglia where χ was observed to be lower at 10.5 T than at 7 T. The normalized R 2 * contrast that is, the R 2 * difference normalized by the mean R 2 *, increased by about 3% between brain regions and 12% between cortical depths from 7 to 10.5 T. Conclusion: It is feasible to achieve high‐quality mesoscale whole‐brain T 2 *w MRI at 10.5 T and associated quantitative R 2 * and χ mapping. Our results may aid future optimization of anatomic T 2 *w brain MRI at ultrahigh field beyond 7 T.

  • 500 MHz Inductive Birdcage RF Coil for Brain MRI: Design, Implementation and Validation

    by Joe Murphy-Boesch, Jacco A de Zwart, Peter van Gelderen, Stephen J Dodd, Frank Mauconduit, Alexandre Vignaud, Nicolas Boulant, Alan P Koretsky, Jeff H Duyn, Natalia Gudino

    Objective: We present a 500 MHz inductive birdcage RF resonator for imaging the human brain in an 11.7 T MRI scanner. Methods: A homogenous circularly polarized transmit field ($\text{B}_{1}^{+}$) was generated by transmitting power to the resonator through four couplers driven in differential mode and with an incremental 90-degree phase delay. A detailed mechanical and electrical model of the hardware, loaded with different phantoms, was generated and its performance simulated using a finite-difference time-domain method. Results: The head-size inductively coupled birdcage presented a fundamental mode at 500 MHz. MR thermometry maps were in good agreement with heating profiles estimated from simulated SAR maps Conclusion: The model of the hardware was validated through both bench and MRI measurements. Significance: This validation is important for future analysis of radiofrequency safety and performance at ultra-high field MRI through the prediction of SAR and $\text{B}_{1}^{+}$ profiles across different human brain models at various positions inside the coil.

  • Open Access

    Dependence of brain‐tissue R2 on MRI field strength

    by Peter van Gelderen, Yicun Wang, Jacco A. de Zwart, Jeff H. Duyn

    Purpose: To quantify T2 relaxation in the brain at 3 T and 7 T to study its field dependence and correlation with iron content, and to investigate whether iron can be separated from other sources of T2 relaxation based on this field dependence.Methods: Nine subjects were scanned at both field strengths with the same acquisition technique, which used multiple gradient‐echo sampling of a spin echo. This allowed for separation of T2 relaxation from static dephasing by B0 field inhomogeneities and the effects of radiofrequency refocusing imperfections. The average relaxation rates (R2 = 1/T2) in multiple regions of interest in the brain were fitted with a model linear in B0 and correlated with literature iron values.Results: The relationship between the R2 values at the two field strengths appeared to be linear over all regions of interest. The R2 values (in s−1) in the regions of interest for which both an iron and a lipid mass fraction have been documented in the literature were fitted as , where and indicate the putative mass fractions of iron and lipid.Conclusion: The R2 relaxation rate is well described by a constant plus a term linear in B0, with both iron and lipid content contributing to the slope. This indicates that the contributions of lipid and iron to R2 cannot be separated based solely on the field dependence of R2 in the field range of 3–7 T.


  • Accelerated multislice MRI with patterned excitation

    by Jacco A. de Zwart, Peter van Gelderen, Yicun Wang, Jeff H. Duyn

    Purpose: Accelerate multislice 2D MRI by using RF pulses that simultaneously act on different slices to combine contrast preparation and image acquisition.Theory and Methods: MRI applications often require the use of multiple RF pulses to generate desired contrast and prepare the signal for readout. Examples are the use of inversion prepulses to generate T1 contrast, or the use of spin‐echo preparations to generate T2 or diffusion contrast. In multislice MRI, this separation of contrast preparation and readout can render scans time‐inefficient and lengthy. We introduce a class of pulse sequences that overcomes this inefficiency by combining contrast preparation and signal readout. This is accomplished by using RF pulses that manipulate the magnetization of multiple slices simultaneously and a gradient crusher scheme that selects a target slice for readout.Results: Feasibility of the method was demonstrated for spin echo–based measurement of water diffusion and tissue pulsation in human brain at 3 T. Increases in time‐efficiency and reductions in scan time were highly dependent on specific implementation and reached as high as 25% and 53%, respectively.Conclusion: A novel approach to multislice MRI is demonstrated that reduces scan time for specific applications.


  • Open Access

    Multiple sclerosis cortical lesion detection with deep learning at ultra-high-field MRI

    by Francesco La Rosa, Erin S. Beck, Josefina Maranzano, Ramona-Alexandra Todea, Peter van Gelderen, Jacco A. de Zwart, Nicholas J. Luciano, Jeff H. Duyn, Jean-Philippe Thiran, Cristina Granziera, et al.

    Manually segmenting multiple sclerosis (MS) cortical lesions (CL) is extremely time-consuming, and past studies have shown only moderate inter-rater reliability. To accelerate this task, we developed a deep learning-based framework (CLAIMS: Cortical Lesion Artificial Intelligence-based assessment in Multiple Sclerosis) for the automated detection and classification of MS CL with 7T MRI. Two 7T datasets, acquired at different sites, were considered. The first consisted of 60 scans that include 0.5mm isotropic MP2RAGE acquired 4 times (MP2RAGEx4), 0.7mm MP2RAGE, 0.5mm T2*-weighted GRE, and 0.5mm T2*-weighted EPI. The second dataset consisted of 20 scans including only 0.75×0.75×0.9 mm MP2RAGE. CLAIMS was first evaluated using 6-fold cross-validation with single and multi-contrast 0.5mm MRI input. Second, performance of the model was tested on 0.7mm MP2RAGE images after training with either 0.5mm MP2RAGEx4, 0.7mm MP2RAGE, or alternating the two. Third, its generalizability was evaluated on the second external dataset and compared with a state-of-the-art technique based on partial volume estimation and topological constraints (MSLAST). CLAIMS trained only with MP2RAGEx4 achieved comparable results to the multi-contrast model, reaching a CL true positive rate of 74% with a false positive rate of 30%. Detection rate was excellent for leukocortical and subpial lesions (83%, and 70%, respectively), whereas it reached 53% for intracortical lesions. The correlation between disability measures and CL count was similar for manual and CLAIMS lesion counts. Applying a domain-scanner adaptation approach and testing CLAIMS on the second dataset, the performance was superior to MSLAST when considering a minimum lesion volume of 6μL (lesion-wise detection rate of 71% vs 48%). The proposed framework outperforms previous state-of-the-art methods for automated CL detection across scanners and protocols. In the future, CLAIMS may be useful to support clinical decisions at 7T MRI, especially in the field of diagnosis and differential diagnosis of multiple sclerosis patients.

  • Open Access

    Sensitivity limitations of high-resolution perfusion-based human fMRI at 7 Tesla

    by Jacco A. de Zwart, Peter van Gelderen, Jeff H. Duyn


  • FMRI based on transition‐band balanced SSFP in comparison with EPI on a high‐performance 0.55 T scanner

    by Yicun Wang, Peter van Gelderen, Jacco A. de Zwart, Adrienne E. Campbell‐Washburn, Jeff H. Duyn

    Purpose: Low‐field (<1 tesla) MRI scanners allow more widespread diagnostic use for a range of cardiac, musculoskeletal, and neurological applications. However, the feasibility of performing robust fMRI at low field has yet to be fully demonstrated. To address this gap, we investigated task‐based fMRI using a highly sensitive transition‐band balanced steady‐state free precession approach and standard EPI on a 0.55 tesla scanner equipped with modern high‐performance gradient coils and a receive array.Methods: TR and flip‐angle of transition‐band steady‐state free precession were optimized for 0.55 tesla by simulations. Static shimming was employed to compensate for concomitant field effects. Visual task‐based fMRI data were acquired from 8 healthy volunteers. For comparison, standard EPI data were also acquired with TE = . Retrospective image‐based correction for physiological effects (RETROICOR) was used to quantify physiological noise effects.Results: Activation was robustly detected using both methods in a 4‐min scan time. Transition‐band steady‐state free precession was found to be sensitive to interference from subtle spatial and temporal (field drift, respiration) variations in the magnetic field, counteracting potential advantages of the reduced magnetic susceptibility effects compared to its utilization at high field. These adverse effects could be partially remedied with static shimming and postprocessing approaches. Standard EPI proved more robust against the sources of interference.Conclusion: BOLD contrast is sufficiently large at 0.55 tesla for robust detection of brain activation and may be employed to broaden the spectrum of applications of low‐field MRI. Standard EPI outperforms transition‐band steady‐state free precession in terms of signal stability.


  • Background suppressed magnetization transfer MRI

    by Peter van Gelderen, Jeff H. Duyn

    Purpose: Up to 30% of the hydrogen atoms in brain tissue are part of molecules (“semisolids”) other than water. In MRI, their magnetization is typically not observed directly, but can influence the water magnetization through magnetization transfer (MT). Comparison of MRI scans differentially sensitized to MT allows estimation of the semisolid fraction and potential changes with disease. Here, we present an approach designed to improve this estimate by measuring the size of the MT effect in a single scan.Methods: A stimulated echo sequence was used to generate a spatial pattern in the longitudinal water magnetization, which was then given time to exchange with semisolids. After saturating the remaining water magnetization, reverse exchange was allowed to partly re‐establish the original water magnetization pattern. The third excitation pulse then formed a stimulated echo out of this pattern.Results: MT data were obtained on 10 human subjects at 7 T with varying exchange times. The images showed the expected time dependence of signal associated with the forward and reverse exchange processes. Excellent suppression of non‐exchanging background signal was achieved. As expected, this suppression came at the price of a substantial reduction in exchange‐related signal (by ~75% compared to the signal in saturation recovery MT), in part because of the reliance on a 2‐step exchange process.Conclusion: The results demonstrate an MT signal can be observed in a single acquisition without subtraction. This may be advantageous for MT measurements when signal instabilities related to motion and physiological variations exceed thermal noise sources.


  • White matter intercompartmental water exchange rates determined from detailed modeling of the myelin sheath

    by Peter van Gelderen, Jeff H Duyn

    Purpose: Magnetization exchange (ME) between hydrogen protons of water and large molecules (semisolids [SS]) in lipid bilayers is an important factor in MRI signal generation and can be exploited to study white matter pathology. Current models used to quantify ME in white matter generally consider water to reside in 1 or 2 distinct compartments, ignoring the complexities of the myelin sheath’s multicompartment structure of alternating myelin SS and myelin water (MW) layers. Here, we investigated the effect of this by fitting ME data obtained from human brain at 7 T with a multilayer model of myelin.Methods: A multi‐echo acquisition for a T2*‐based separation of MW from other water signals was combined with various preparation pulses to change the (relative) state of the SS and water pools and analyzed by fitting with a multilayer exchange model.Results: The estimated lifetime within a single MW layer was 260 µs, corresponding to a lipid bilayer permeability of 6.7 µm/s. The magnetization lifetime of the aggregate of all MW was estimated at 13 ms, shorter than previously reported values in the range of 40 to 140 ms.Conclusion: Contrary to expectations and previous reports, ME between protons in myelin SS and water is not limited by the myelin sheath but rather by the exchange between SS and water protons. The analysis of ME contrast should account for the relatively short MW lifetime and affects the interpretation of tissue compartmentalization from MRI contrasts such as T1‐ and diffusion‐weighting.


  • Open Access

    A torque balance measurement of anisotropy of the magnetic susceptibility in white matter

    by Peter van Gelderen, Hendrik Mandelkow, Jacco A. de Zwart, Jeff H. Duyn

    Purpose Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment‐specific information. This study provides an independent confirmation and quantification of this anisotropy. Methods Anisotropic magnetic susceptibility results in a torque exerted on WM when placed in a uniform magnetic field, tending to align the WM fibers with the field. To quantify the effect, excised spinal cord samples were placed in a torque balance inside the magnet of a 7 T MRI system and the magnetic torque was measured as function of orientation. Results All tissue samples (n = 5) showed orienting effects, confirming the presence of anisotropic susceptibility. Analysis of the magnetic torque resulted in reproducible values for the WM volume anisotropy that ranged from 13.6 to 19.2 ppb. Conclusion The independently determined anisotropy values confirm estimates inferred from MRI experiments and validate the use of anisotropy to extract novel information about brain fiber structure and myelination. Magn Reson Med 74:1388–1396, 2015.