The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography
Authors:
- 1 November 2017
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 62 (1) , 48-53
Abstract
Purpose To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. Methods In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Results Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Conclusions Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.Keywords
This publication has 24 references indexed in Scilit:
- Association between light-to-dark changes in angle width and iris parameters in light, dark and changes from light-to-dark conditionsBritish Journal of Ophthalmology, 2016
- Dynamic Iris Changes as a Risk Factor in Primary Angle Closure DiseaseInvestigative Ophthalmology & Visual Science, 2016
- Primary Open-Angle Glaucoma in a Population Associated with High Prevalence of Primary Angle-Closure GlaucomaOphthalmology, 2014
- Prevalence and Causes of Low Vision and Blindness in a Rural Southwest Island of JapanOphthalmology, 2010
- Ultrasound Biomicroscopic Configurations of the Anterior Ocular Segment in a Population-Based StudyOphthalmology, 2010
- Plateau Iris Configuration and Dark–light Changes in Anterior Segment Optical Coherence TomographyOphthalmic Surgery, Lasers and Imaging Retina, 2010
- The number of people with glaucoma worldwide in 2010 and 2020British Journal of Ophthalmology, 2006
- Glaucoma in China: how big is the problem?British Journal of Ophthalmology, 2001
- An Ultrasound Biomicroscopic Dark-Room Provocative TestOphthalmic Surgery, Lasers and Imaging Retina, 1995
- Human Vision and the SpectrumScience, 1945