Hiroshi Sakai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroshi Sakai has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Michiko Yonahara
Ophthalmology, University of the Ryukyus, 207 Uehara, Nishihara, Okinawa, 903-0215, Japan
2 shared publicationsMiyako Sakai
Ophthalmology, University of the Ryukyus, Nishihara, Japan
2 shared publicationsShoichi Sawaguchi
Department of Ophthalmology, University of the Ryukyus Faculty of Medicine, Okinawa, Japan
2 shared publicationsYoshimi Nakamura
Department of Ophthalmology, University of the Ryukyus Faculty of Medicine, Okinawa, Japan
2 shared publicationsHideo Ishikawa
Ishikawa Eye Clinic, Naha-city, Okinawa, Japan (H.I.)
1 shared publicationManabu Shinzato
Department of Ophthalmology, University of the Ryukyus Medical Department Hospital, Nishihara-cho, Okinawa, Japan (H.S., M.S., Y.N., S.S.)
1 shared publication
Latest Publications
- 1 November 2017
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 62 (1) , 48-53
The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography
Purpose To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. Methods In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Results Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Conclusions Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.
- 1 November 2017
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 62 (1) , 48-53
The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography
Purpose To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. Methods In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Results Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Conclusions Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.
- Open Access
- 17 January 2017
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 8 (1) , 26-30
Recurrent Uveal Effusion after Laser Iridotomy
A 59-year-old woman was seen by an ophthalmologist for blurred vision, ocular pain, headache, and nausea. She was diagnosed with acute primary angle closure (APAC) and successfully treated with medications. Using ultrasound biomicroscopy (UBM), engorged episcleral vein was observed and small uveal effusion was diagnosed after laser peripheral iridotomy (LPI). The uveal effusion disappeared and was again diagnosed by UBM together with anterior segment inflammation with ocular pain. Iritis caused by LPI after APAC might be a cause of uveal effusion in this specific case.
- 17 January 2017
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 8 (1) , 26-30
Open AccessRecurrent Uveal Effusion after Laser Iridotomy
A 59-year-old woman was seen by an ophthalmologist for blurred vision, ocular pain, headache, and nausea. She was diagnosed with acute primary angle closure (APAC) and successfully treated with medications. Using ultrasound biomicroscopy (UBM), engorged episcleral vein was observed and small uveal effusion was diagnosed after laser peripheral iridotomy (LPI). The uveal effusion disappeared and was again diagnosed by UBM together with anterior segment inflammation with ocular pain. Iritis caused by LPI after APAC might be a cause of uveal effusion in this specific case.
- 1 December 2005
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 21 (6) , 483-489
Comparison of Latanoprost Monotherapy and Combined Therapy of 0.5% Timolol and 1% Dorzolamide in Chronic Primary Angle-Closure Glaucoma (CACG) in Japanese Patients
To compare the efficacy, adverse effects, and patient compliance of latanoprost monotherapy with unfixed combination therapy with 0.5% timolol maleate and 1% dorzolamide in the treatment of chronic primary angle-closure glaucoma (CACG), 36 Japanese patients with CACG following laser iridotomy (LPI) were treated for 12 weeks with instillation of latanoprost alone or with unfixed combination therapy of 0.5% timolol maleate and 1% dorzolamide hydrochloride. After 12 weeks of treatment, latanoprost reduced intraocular pressure (IOP) from 22.2 ± 2.0 mmHg to 14.8 ± 1.9 mmHg (33% reduction); timolol maleate and dorzolamide hydrochloride also reduced IOP from 22.5 ± 2.2 mmHg to 17.1 ± 2.7 mmHg (24% reduction). Latanoprost monotherapy significantly lowered IOP compared with unfixed combination therapy of 0.5% timolol maleate and 1% dorzolamide hydrochloride. Furthermore, a systemic adverse effect of bradycardia was not observed in the latanoprost monotherapy group. Concerning compliance, no significant difference was observed between the two groups. Thus, latanoprost monotherapy is more effective than unfixed combination therapy with 0.5% timolol maleate and 1% dorzolamide in the treatment of CACG following relief of pupillary block in Japanese patients.
- 1 December 2005
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 21 (6) , 483-489
Comparison of Latanoprost Monotherapy and Combined Therapy of 0.5% Timolol and 1% Dorzolamide in Chronic Primary Angle-Closure Glaucoma (CACG) in Japanese Patients
To compare the efficacy, adverse effects, and patient compliance of latanoprost monotherapy with unfixed combination therapy with 0.5% timolol maleate and 1% dorzolamide in the treatment of chronic primary angle-closure glaucoma (CACG), 36 Japanese patients with CACG following laser iridotomy (LPI) were treated for 12 weeks with instillation of latanoprost alone or with unfixed combination therapy of 0.5% timolol maleate and 1% dorzolamide hydrochloride. After 12 weeks of treatment, latanoprost reduced intraocular pressure (IOP) from 22.2 ± 2.0 mmHg to 14.8 ± 1.9 mmHg (33% reduction); timolol maleate and dorzolamide hydrochloride also reduced IOP from 22.5 ± 2.2 mmHg to 17.1 ± 2.7 mmHg (24% reduction). Latanoprost monotherapy significantly lowered IOP compared with unfixed combination therapy of 0.5% timolol maleate and 1% dorzolamide hydrochloride. Furthermore, a systemic adverse effect of bradycardia was not observed in the latanoprost monotherapy group. Concerning compliance, no significant difference was observed between the two groups. Thus, latanoprost monotherapy is more effective than unfixed combination therapy with 0.5% timolol maleate and 1% dorzolamide in the treatment of CACG following relief of pupillary block in Japanese patients.
- 1 September 2003
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 136 (3) , 537-538
Prevalence of ciliochoroidal effusion after prophylactic laser iridotomy
- 1 September 2003
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 136 (3) , 537-538
Prevalence of ciliochoroidal effusion after prophylactic laser iridotomy