Minimally Invasive Measurement of Cardiac Output during Surgery and Critical Care
Top Cited Papers
Open Access
- 1 November 2010
- journal article
- review article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 113 (5) , 1220-1235
Abstract
THERE is increasing interest in better hemodynamic management, incorporating cardiac output measurement, to achieve improvements in patient outcomes during major surgery.1–3 A number of methods and technologies are now available for minimally invasive or noninvasive cardiac output monitoring in the perioperative period. These include pulse contour and esophageal Doppler devices, the partial carbon dioxide rebreathing (Pco2RB) method, and transthoracic electrical bioimpedance (TEB).3 However, these methods have not achieved widespread use in routine practice.4 The reasons for this include cost, of both the devices and their disposable components, invasiveness, and concerns about their accuracy, precision, and reproducibility.Keywords
This publication has 80 references indexed in Scilit:
- Improved Accuracy Of Cardiac Output Estimation By The Partial CO2 Rebreathing MethodJournal of Clinical Monitoring and Computing, 2009
- Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick methodJournal of Clinical Monitoring and Computing, 2008
- Cardiac output determination by thermodilution and arterial pulse waveform analysis in patients undergoing aortic valve replacementCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2008
- Non-invasive Cardiac Output by Transthoracic Electrical Bioimpedence in Post-cardiac Surgery Patients: Comparison with Thermodilution MethodJournal of Clinical Monitoring and Computing, 2008
- Lack of agreement between thermodilution and electrical velocimetry cardiac output measurementsIntensive Care Medicine, 2007
- A pilot assessment of the FloTracTM cardiac output monitoring systemIntensive Care Medicine, 2006
- RETRACTED ARTICLE: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilutionIntensive Care Medicine, 2006
- Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysisJournal of Clinical Anesthesia, 2005
- A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilationIntensive Care Medicine, 2003
- Evaluation of a noninvasive method for cardiac output measurement in critical care patientsIntensive Care Medicine, 2002