The Effect of Emboss Enhancement on Reliability of Landmark Identification in Digital Lateral Cephalometric Images
Open Access
- 22 April 2014
- journal article
- research article
- Published by Brieflands in Iranian Journal of Radiology
- Vol. 12 (2) , e19302
Abstract
Background: Evaluation of the craniofacial bones is the oldest method to measure the facial proportion ratio in orthodontics. Objectives: The purpose of this study was to evaluate the effect of emboss enhancement on the reliability of landmark identification in digital lateral cephalometric images. Materials and Methods: Ten digital lateral cephalograms were selected from the archive of an oral and maxillofacial radiology center. Using DIGORA software, these images were saved in two formats; common images and 3D emboss images. On these images, 32 skeletal, dental, and soft tissue landmarks were marked at least twice with a 2-week interval by four observers (two radiologists and two orthodontists). In order to determine the position of the marked landmarks (in x and y coordinates), a software was designed. The statistical analysis was performed in SPSS software and the reliability of each observer was obtained by means of intraclass correlation coefficient (ICC). Results: In three skeletal landmarks [Orbit (Or), condyl top (Cond), and pogonion (Pog)], the enhancement caused significant reduction in the reliability, and in four skeletal [Anterior Nasal Spine (ANS), B, A, and Basion (Ba)], two dental (U1 root, L1 incisal), and one soft tissue landmark (Menton soft tissue), the enhancement increased the reliability of landmark detection between the two phases of the study. Totally, ICC of embossed images in both x and y coordinates were greater than the typical images, but the difference was not statistically significant. However, the effect of enhancement on the improvement of the reliability of landmark identification was higher in the x-axis than the y-axis. Conclusions: Using embossed images is only effective in increasing the reliability of detection in a few numbers of cephalometric landmarks. Keywords: Cephalometry; Emboss Enhancement; ReliabilityKeywords
This publication has 13 references indexed in Scilit:
- Accuracy of cephalometric landmarks on monitor-displayed radiographs with and without image emboss enhancementEuropean Journal of Orthodontics, 2009
- Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomographyin vivoDentomaxillofacial Radiology, 2009
- Embossed radiography utilizing energy subtractionRadiological Physics and Technology, 2009
- Cephalometric landmark clarity in photostimulable phosphor images using pseudo-color and emboss enhancementsInternational Journal of Computer Assisted Radiology and Surgery, 2006
- Effect of Pixel Histogram Distribution on Perceived Anatomical Landmark Clarity of Photostimulable Phosphor CephalogramsInternational Journal of Computer Assisted Radiology and Surgery, 2006
- Reliability of landmark identification in cephalometric radiography acquired by a storage phosphor imaging systemDentomaxillofacial Radiology, 2004
- Dose reduction by direct-digital cephalometric radiography.2001
- Diagnostic yield of conventional and digital cephalometric images: a human cadaver studyDentomaxillofacial Radiology, 2001
- Reliability of landmark recording on film and digital lateral cephalogramsEuropean Journal of Orthodontics, 1993
- Digital Image Processing of Cephalometric Radiographs: A Preliminary ReportBritish Journal of Orthodontics, 1985