HHHoora Hadian

Hoora Hadian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hoora Hadian has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Nika Bahemmat

    Department of Oral and Maxillofacial Radiology, Dental Faculty, Alborz University of Medical Sciences, Karaj, Iran

    2 shared publications
  • Sima Nikneshan

    Department of Oral and Maxillofacial Radiology School of Dentistry Shahid Beheshti University of Medical Sciences Tehran Iran

    2 shared publications
  • Sima Nikneshan

    Department of Oral and Maxillofacial Radiology, Dental Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    2 shared publications
  • A.V. Oleinikov

    Department of Biological Chemistry, School of Medicine, University of California, Davis, CA 95616, USA

    1 shared publication
  • Ali Seifi

    Department of Oral and Maxillofacial Radiology, School of Dentistry, Mazandaran University of Medical Sciences, Sari, Iran

    1 shared publication
  • Azadeh Esmaeil Nejad

    Assistant Professor, Department of Periodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    1 shared publication

Latest Publications

  • Open Access

    Effect of Artifact Reduction on the Diagnosis of Vertical Root Fracture in Teeth with Posts Using CBCT

    by Sima Nikneshan, Pouria Javaheri, Hoora Hadian

    In the absence of clear clinical and radiographic signs, detection of vertical root fractures in teeth receiving root treatment is an important clinical cha ...


  • Open Access

    Relationship between bridging and dimensions of sella turcica with classification of craniofacial skeleton

    by Farhad Sobuti, Sepideh Dadgar, Ali Seifi, Seyed Jaber Musavi, Hoora Hadian

    Purpose: In orthodontics, it is essential to determine the craniofacial skeleton pattern (class I, II, III) for planning treatment. Sella turcica bridging that is seen on lateral cephalometric radiographs is considered as a normal finding. This study aimed to compare sella turcica bridging and its dimensions in patients with various craniofacial patterns.Material and methods: A total of 105 lateral cephalometric radiographs (53 men and 52 women), aged 14–26 years, were randomly and equally assigned to three groups of class I, II, and III, respectively. The length, diameter, and depth of the sella turcica as well as sella turcica bridging were determined on radiographs. The chi-squared test was used for assessing the relationship between sella turcica bridging and craniofacial skeleton classification. ANOVA was used for assessing the relationship between the dimensions of the sella turcica and craniofacial skeleton classification. The Pearson’s correlation coefficient was used for assessing the relationship between age and the dimensions of the sella turcica.Results: The sella turcica had a normal shape in 64.76% of patients, whereas 35.33% of patients had sella turcica bridging. In total, 11.42% of patients belonged to class I, 34.28% to class II, and 66.62% to class III. The diameter of the sella turcica had a significant relationship with age; the diameter of the sella turcica increased with age (p < 0.001).Conclusions: There is a significant relationship between craniofacial skeleton patterns and sella turcica bridging, i.e., the incidence of sella turcica bridging is higher in class III patients. The sella turcica had a greater diameter in older patients.


  • Open Access

    Dosimetry of Three Cone Beam Computerized Tomography Scanners at Different Fields of View in Terms of Various Head and Neck Organs

    by Sima Nikneshan, Mahmood Reza Aghamiri, Ehsan Moudi, Nika Bahemmat, Hoora Hadian

    Background: Marketing new radiography devices necessitates documenting their absorbed X-ray doses. Since the current literature lacks studies on new devices, we assessed the doses of two new devices that had not previously been assessed. Objectives: The new devices were compared to the Promax three dimensional (3D) scanner at two fields of view (FOV) in nine critical head and neck tissues and organs. Materials and Methods: Seventeen thermoluminescence dosimeters positioned in an average-sized male RANDO phantom were used to determine the dosimetry of the three cone beam computerized tomography devices (NewTom VGi, NewTom 5G, and Promax 3D) at two field of views (FOVs), one small and one large. The exposure by each device per FOV was performed five times (30 exposures). The absorbed and effective doses were calculated for the thyroid, parotid, submandibular gland, sublingual gland, calvarium, cervical vertebra, trunk of the mandible, and mandibular ramus. The doses pertaining to the different devices, the FOVs, and the tissues were compared using the Kruskal-Wallis, Mann-Whitney U, and Wilcoxon tests. Results: The average absorbed doses, respectively, for the large and small FOVs were 17.19 and 28.89 mGy in the Promax 3D, 19.25 and 35.46 mGy in the NewTom VGi, and 18.85 and 30.63 mGy in the NewTom 5G. The absorbed doses related to the FOVs were not significantly different (P value = 0.1930). However, the effective doses were significantly greater at the smaller FOVs / higher resolutions (P = 0.0039). The doses of the three devices were not significantly different (P = 0.8944). The difference among the nine organs/tissues was significant (Kruskal-Wallis P=0.0000). Conclusion: The absorbed doses pertaining to the devices and the FOVs were not significantly different, although the organs/tissues absorbed considerably different doses. Keywords: Cone Beam Computed Tomography; Dosimetry; Field of View; Resolution; Absorbed Dose; Effective Dose


  • Reliability and Reproducibility of Linear Measurements of Alveolar Ridges Using Cone-beam CT Made by Radiologists and Periodontists

    by Yaser Safi, Mahdi Kadkhodazadeh, Azadeh Esmaeil Nejad, Zahra Vasegh, Reza Amid, Hamid Reza Khalighi, Hoora Hadian, Nika Bahemmat

    Background and aims. The aim of this study was to evaluate the intra- and inter-examiner reliability and reproducibility of linear measurements on cone-beam computed tomography (CBCT) images made by calibrated radiologists and periodontists. Materials and methods. The alveolar ridge dimensions were measured on selected CBCT images by two calibrated radiologists and two periodontists. Intra- and inter-examiner reliability was evaluated by intra-rater and intra-class correlation coefficients (ICCs). Results. Intra- and inter-examiners ICCs obtained with the different methods showed almost perfect matches. The results demonstrated high examiner reproducibility for linear parameters of alveolar ridges on CBCT images in presurgical implant site assessments. Conclusion. The alveolar ridge dimensions provided by the radiologists might be useful for the periodontists. The measurements with small differences were related to the experience and skills of the examiner, inclination measurement, selection of the exact level of the alveolar crest and the ability to detect the exact anatomic borders on CBCT images.


  • Open Access

    Unusual Aggressive Radiographic Appearance of Simple Bone Cyst (A Case Report and Review of Literature)

    by Sima Nikneshan, Hoora Hadian

    Aim: This study reports a rare case of simple bone cyst (SBC) with a radiographic behavior similar to malignancies and a mixed internal structure in a 43 year-old woman who presented to a dental office with clinical symptoms. Presentation of Case: A 43 year-old woman presented to a dental office with chief complaint of pain at left mandibular molars for almost 2 months. She was wearing a cervical collar for some spine problems. The panoramic x-ray showed a radiolucent lesion with well defined non-corticated borders in periapical region of the mandibular left first molar (tooth 36). The tooth was vital. Cone Beam Computed Tomography (CBCT) images showed a lytic lesion with well defined non-corticated borders that destructs the lingual cortical wall without any sign of expansion to soft tissues. The upper border of the mandibular canal was unclear and seemed destructed by the lesion. The internal structure of the lesion seemed mixed. Three months later, the patient reported numbness of her lower lip. CBCT showed an enlargement of the lesion and the presence of buccal cortical perforation was seen. On biopsy the lesion was diagnosed as a Simple Bone Cyst (SBC). Discussion: SBC is often a benign lesion which appears as a radiolucent lesion with scalloped corticated borders. Adversely, current case showS a mixed lesion with buccal and lingual cortical perforation and rapid growth .the concomitant pain, the lower lip numbness and the radiographic appearance suggest the probability of an aggressive local condition or a malignancy Conclusion: SBC may have various radiographic presentations, unusual SBCs (or Traumatic bone cysts TBCs) may show aggressive radiographic characters. In these cases, biopsy and pathological features are necessary for diagnosis.


  • Open Access

    Relationship Between Carotid Artery Calcification and Dental Panoramic Images,Hypertension and Myocardial Infarction

    by Mahkameh Moshfeghi, Jamileh Beigom Taheri, Nika Bahemmat, Mohammad Ebrahim Evazzadeh, Hoora Hadian

    Background: Carotid artery calcification may be related to cerebrovascular accident, which may result in death or physical and mental disabilities in survivors. Objectives: Our purpose is to study the association of carotid artery calcification (CAC) on dental panoramic radiographs and two risk factors of cerebrovascular accident (CVA) including hypertension and myocardial infarction (MI). Patients and Methods: Panoramic images of 200 patients that were all women above 50 years of age (a population suffering from vascular diseases) were investigated. All panoramic images were provided under similar conditions in terms of the type of panoramic radiograph equipment, type of applied films and the automatic film processor. Then, the patients answered questions about MI history and taking antihypertensive drugs. We also measured the blood pressure of patients in two separate surveys. Data analysis was performed by SPSS statistical program. We used Exact Fisher test and Chi-Square test at a significant level of less than 0.05 to study the effect of these variables on the occurrence of carotid artery calcification. Results: Among 200 studied samples, 22 of the patients (11%) had carotid artery calcification on the dental panoramic radiograph. In total, 52 patients (26%) had hypertension and four people (2%) had a history of MI. Eleven individuals among patients suffering from hypertension (21.2%) and three individuals among patients with a history of MI (75%) demonstrated CAC on dental panoramic images . Conclusions: The relationship between CAC found on dental panoramic radiographs and two CVA risk factors--hypertension and MI-- was significant. Therefore, it seems that detection of CAC on panoramic images of dental patients must be considered by dentists. Keywords: Carotid Artery; Stroke; Panoramic Radiography


  • Open Access

    The Effect of Emboss Enhancement on Reliability of Landmark Identification in Digital Lateral Cephalometric Images

    by Sima Nikneshan, Sudeh Mohseni, Mahtab Nouri, Hoora Hadian, Mohammad Javad Kharazifard

    Background: Evaluation of the craniofacial bones is the oldest method to measure the facial proportion ratio in orthodontics. Objectives: The purpose of this study was to evaluate the effect of emboss enhancement on the reliability of landmark identification in digital lateral cephalometric images. Materials and Methods: Ten digital lateral cephalograms were selected from the archive of an oral and maxillofacial radiology center. Using DIGORA software, these images were saved in two formats; common images and 3D emboss images. On these images, 32 skeletal, dental, and soft tissue landmarks were marked at least twice with a 2-week interval by four observers (two radiologists and two orthodontists). In order to determine the position of the marked landmarks (in x and y coordinates), a software was designed. The statistical analysis was performed in SPSS software and the reliability of each observer was obtained by means of intraclass correlation coefficient (ICC). Results: In three skeletal landmarks [Orbit (Or), condyl top (Cond), and pogonion (Pog)], the enhancement caused significant reduction in the reliability, and in four skeletal [Anterior Nasal Spine (ANS), B, A, and Basion (Ba)], two dental (U1 root, L1 incisal), and one soft tissue landmark (Menton soft tissue), the enhancement increased the reliability of landmark detection between the two phases of the study. Totally, ICC of embossed images in both x and y coordinates were greater than the typical images, but the difference was not statistically significant. However, the effect of enhancement on the improvement of the reliability of landmark identification was higher in the x-axis than the y-axis. Conclusions: Using embossed images is only effective in increasing the reliability of detection in a few numbers of cephalometric landmarks. Keywords: Cephalometry; Emboss Enhancement; Reliability


    • 1 January 2011
      • Vol. 2  (4) , 314-20

    Validity and reliability of the Persian version of the oral health impact profile (OHIP)-14.

    by Mina Motallebnejad, Hoora Hadian, Shervin Mehdizadeh, Mahmoud Hajiahmadi

    The need for assessment of oral health related quality of life has been increased over the last decades. The aim of this study was to develop a Persian version of the Oral Health Impact Profile (OHIP)-14 and to evaluate its reliability and validity for its use in Persian-speaking communities. The original version of the OHIP-14 was translated into the Persian language using the back-translation technique. To establish the reliability of the translated instrument, internal consistency and test-retest reliability trials were performed on 20 subjects (at 4-week intervals); Cronbach's alpha was used. One hundred sixty adults over 50 years of age who attended Health Care Centers in Sari and Babol were recruited to fill out the questionnaires and received a clinical examination by a single dentist. The socio-demographic and oral health information was also collected. The test-retest reliability was excellent (Cronbach's alpha = 0.095). In the main study, Cronbach's reliability coefficient for all 14 questions in each dimension was more than 70%. The individuals in need of dental treatment showed significantly higher OHIP scores than the individuals not requiring treatment. The individuals with hopeless teeth, negative self-perceived oral had significantly higher OHIP scores. The Persian version of the OHIP-14 is a comprehensive and accurate instrument with acceptable reliability and validity for measuring oral health-related quality of life.