Intake fraction distributions for indoor VOC sources in five European cities
- 1 October 2007
- journal article
- Published by Hindawi Limited in Indoor Air
- Vol. 17 (5) , 372-383
Abstract
Distributions of intake fractions for indoor air emissions were estimated for five cities in the EXPOLIS study (Athens, Basel, Helsinki, Oxford, and Prague). Intake fractions are an expression of the mass of a pollutant that reaches a target compared with the mass emitted by a source. They facilitate direct comparisons of the relative impact of different sources on individual or population exposure and dose. The computation of the distributions was obtained through Monte Carlo simulations, based on distributions of residence volume, air exchange rates and time-activity data, calculated from the EXPOLIS database, as well as on distributions from the literature. Some approximations were made that are valid for persistent pollutants and continuous sources, such as emissions from building materials, pesticides, molds, as well as for certain non-continuous sources such as cooking or cleaning products. For these categories of sources, intake fractions are approximately independent of the actual indoor concentrations and irrespective of the source. Intake fractions in the five populations examined followed approximately lognormal distributions. The mean individual intake fractions exhibited some variability across cities, ranging from 1.5x10(-3) in Athens to 4.5x10(-3) in Helsinki. Intake fractions for all the people in a household followed similar distributions, with mean values ranging from 4.6x10(-3) in Athens to 11.8x10(-3) in Helsinki. This modest variability mostly reflects the differences in climates and consequent air-tightness of the buildings. The 95th percentile of the distributions were two to three times the mean values, indicating substantial homogeneity within each population as well. These results compare well with previous estimates for environmental tobacco smoke and cooking, and are two to three orders of magnitude larger than estimates for outdoor sources.Emissions from indoor sources were estimated to be approximately 1000 times more likely to reach a human target than emissions from outdoor sources. Strategies to reduce exposure to indoor sources can only realistically focus on reducing the strength of the emissions.Keywords
This publication has 9 references indexed in Scilit:
- Modeling residential exposure to secondhand tobacco smokeAtmospheric Environment, 2006
- Infiltration of ambient PM2.5 and levels of indoor generated non-ETS PM2.5 in residences of four European citiesAtmospheric Environment, 2004
- Seasonal cycle of indoor-VOCs: comparison of apartments and citiesAtmospheric Environment, 2004
- Transient analysis of volatile organic compound concentrations for estimating emission ratesAtmospheric Environment, 2003
- Intake fraction of primary pollutants: motor vehicle emissions in the South Coast Air BasinAtmospheric Environment, 2003
- Intake Fraction for Multimedia Pollutants: A Tool for Life Cycle Analysis and Comparative Risk AssessmentRisk Analysis, 2002
- Peer Reviewed: Defining Intake FractionEnvironmental Science & Technology, 2002
- Fuel Combustion, Air Pollution Exposure, and Health: The Situation in Developing CountriesAnnual Review of Energy and the Environment, 1993
- Indoor Climate and the Performance of Ventilation in Finnish ResidencesIndoor Air, 1992