A Simple Positron Emission Tomography-Based Calibration for Perfusion-Weighted Magnetic Resonance Maps to Optimize Penumbral Flow Detection in Acute Stroke
- 1 September 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 41 (9) , 1939-1945
Abstract
Background and Purpose— Perfusion-weighted (PW) MRI is increasingly used to identify the tissue at risk. The adequate PW-MRI map and threshold remain controversial due to a considerable individual variation of values. By comparative positron emission tomography, we evaluated a simple MR-based and positron emission tomography-validated calibration of PW maps. Methods— PW-MRI and quantitative positron emission tomography (15O-water) of patients with acute stroke were used to calculate averaged as well as individual thresholds of penumbral flow (positron emission tomography cerebral blood flow ( Results— In 26 patients, the averaged thresholds were (median/interquartile range): cerebral blood flow 21.7 mL/100 g/min (19.9 to 32); cerebral blood volume 1.5 mL/100 g (0.9 to 1.8); mean transit time seconds 5.2 (3.9 to 6.9); and relative time to peak 4.2 seconds (2.8 to 5.8). The large individual variability was best explained by the mean value of the hemispheric reference derived from a region of interest on a level with the basal ganglia of the unaffected hemisphere ( R 2 : cerebral blood flow 0.76, cerebral blood volume 0.55, mean transit time 0.83, time to peak 0.95). Hemispheric reference-corrected thresholds clearly improved the detection of penumbral flow. Look-up tables were calculated to identify the individual thresholds according to the hemispheric reference value. Conclusion— The individual variation of PW values, even if calculated by deconvolution, remains a major obstacle in quantitative PW imaging and can be significantly improved by a simple MR-based calibration. Easily applicable look-up tables identify the individual best threshold for each PW map to optimize mismatch detection.Keywords
This publication has 22 references indexed in Scilit:
- MRI Perfusion Maps in Acute Stroke Validated With 15O-Water Positron Emission TomographyStroke, 2010
- Improving dynamic susceptibility contrast MRI measurement of quantitative cerebral blood flow using corrections for partial volume and nonlinear contrast relaxivity: A xenon computed tomographic comparative studyJournal of Magnetic Resonance Imaging, 2009
- The Performance of MRI-Based Cerebral Blood Flow Measurements in Acute and Subacute Stroke Compared With 15O-Water Positron Emission TomographyStroke, 2009
- Comparison of 10 Perfusion MRI Parameters in 97 Sub-6-Hour Stroke Patients Using Voxel-Based Receiver Operating Characteristics AnalysisStroke, 2009
- Perfusion MRI (Tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patientsNeurology, 2009
- How Reliable Is Perfusion MR in Acute Stroke?Stroke, 2008
- Benutzerfreundliche Auswertung von MR-Untersuchungen der zerebralen Perfusion: Windows®-basierte BildverarbeitungRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Quantification of Perfusion Using Bolus Tracking Magnetic Resonance Imaging in StrokeStroke, 2002
- Cerebral Hemodynamics in Human Acute Ischemic Stroke: A Study with Diffusion- and Perfusion-Weighted Magnetic Resonance Imaging and SPECTJournal of Cerebral Blood Flow & Metabolism, 2000
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996