Agreement of activity monitors for assessment of patients with sub-acute stroke in an inpatient rehabilitation facility
Authors:
- 6 December 2023
- journal article
- research article
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 19 (6) , 2406-2412
Abstract
Determine the level of agreement of three activity monitors compared with the gold standard (video review) on the activity level of patients with stroke. A prospective, observational, agreement study was performed on 47 individuals with sub-acute stroke in an inpatient rehabilitation facility. Data was collected during one physical therapy session. Individuals wore three device types; Actigraph (AG), Activpal (AP), and stepwatch activity monitor (SAM). Variables assessed were step counts for each limb (hemiparetic and non-hemiparetic) and percent time standing and other. Results from the activity monitors were compared to the video review and assessed for agreement using the intraclass correlation coefficient (ICC) and accuracy of mean difference from video observation. The step counts with the SAM on the non-hemiparetic limb had the highest ICC for step counts (ICC = 0.98, p < 0.001) and were overestimated with 21% accuracy. The SAM on the hemiparetic limb had 9.7% accuracy (ICC = 0.92, p < 0.001). For percent standing time all devices overestimated with poor reliability. For percent other activity time, the AP had the best accuracy and underestimated for both the hemiparetic limb (9.9% accuracy; ICC = 0.90, p < 0.001) and non-hemiparetic limb (8.3% accuracy; ICC = 0.84, p < 0.001). The use of multiple devices may be warranted to capture an accurate understanding of activity levels in this population of individuals with sub-acute stroke. There are concerns with all monitors and clinicians and researchers should be aware of what measures they are wanting to understand about their population.Keywords
This publication has 23 references indexed in Scilit:
- Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired FunctionPhysical Therapy, 2011
- A Novel Approach to Ambulatory MonitoringNeurorehabilitation and Neural Repair, 2010
- Sample size calculation for an agreement studyPharmaceutical Statistics, 2010
- Accelerometer-based wireless body area network to estimate intensity of therapy in post-acute rehabilitationJournal of NeuroEngineering and Rehabilitation, 2008
- Criterion Validity of the StepWatch Activity Monitor as a Measure of Walking Activity in Patients After StrokeArchives of Physical Medicine and Rehabilitation, 2007
- Ambulatory monitoring of activity levels of individuals in the sub-acute stage following stroke: a case seriesJournal of NeuroEngineering and Rehabilitation, 2007
- Predictive Validity and Responsiveness of the Functional Ambulation Category in Hemiparetic Patients After StrokeArchives of Physical Medicine and Rehabilitation, 2007
- The Orpington Prognostic Scale for patients with stroke: Reliability and pilot predictive data for discharge destination and therapeutic servicesDisability and Rehabilitation, 2005
- Effects of Augmented Exercise Therapy Time After StrokeStroke, 2004
- Reliability of the National Institutes of Health Stroke ScaleStroke, 1997