Study on the critical force range of magnetic compression anastomosis in rabbit intestinal tissue
Authors:
Preprint
- 22 August 2023
- preprint
- Published by Springer Nature in Research Square
Abstract
Purpose Magnetic compression anastomosis is a new type of anastomosis that can replace traditional manual suture in the reconstruction of digestive tract anastomosis. One of the important prerequisites for the precise mechanical design of the magnamosis device is to obtain the critical compressive stress for ischemic necrosis of the lumen tissue. Although it is difficult to directly observe the deformation and closure of blood vessels in intestinal tissue under magnetic compression, the external manifestation is tissue necrosis. Therefore, the relationship between vascular deformation and crushing stress can be established by studying the necrosis degree of intestinal tissue under stress. Methods Magnets with different magnetic force groups (0.3、0.4、0.6、0.7、1.0 and 1.2N ) were implanted into each rabbit to form intestinal tissue side-to-side anastomoses. Three experimental press areas were placed for each rabbit. Thirty-six rabbits were euthanized on each of postoperative day 3, day 5 and day 7. Anastomoses were then harvested and compared with respect to direct observation and histology. Results By analyzing the healing state of the tissue in the anastomosis area and the necrosis of the tissue in the anastomotic area, the 0.3N tissue was basically not necrotic, and the 0.4N tissue began to become necrotic, and there was almost no difference between the two specimens at 7 days, and both showed slight healing. Therefore, 0.3N-0.4N is determined as the optimal compressive force range. According to the bottom surface of the magnet device, and the corresponding critical compressive range was 0.88×10− 2 − 1.17×10− 2MPa. Conclusions Through magnetic compression anastomosis experiment of intestinal tissue in rabbits, the critical compressive stress range of intestinal tissue was obtained was 0.88×10− 2 − 1.17×10− 2MPa.Keywords
All Related Versions
This publication has 3 references indexed in Scilit:
- Magnetic ring anastomosis of suprahepatic vena cava: novel technique for liver transplantation in ratTransplant International, 2014
- Magnetic Compression Biliary–enteric Anastomosis for Palliation of Obstructive Jaundice: Initial Clinical ResultsJournal of Vascular and Interventional Radiology, 2009
- Computational modeling of arterial wall growthBiomechanics and Modeling in Mechanobiology, 2006